<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Flow cells &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/uv-detectors-flow-cells/flow-cells/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Wed, 01 Oct 2025 13:05:18 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>Flow cells &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Semi-preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/semipreparativeuvflowcell-a4047/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 08 Mar 2018 12:29:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/semipreparativeuvflowcell-a4047/</guid>

					<description><![CDATA[<p>1/16"  2ul/10mm  PEEK 50ml/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/semipreparativeuvflowcell-a4047/">Semi-preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/16&#8243; Fiber Optics Version</p>
<p>This bioinert semi-preparative UV flow cell with fiber optic connectors is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. Fiber optic cables offer the possibility to separate the flow cell spatially from the detector and thus provides enhanced security for hazardous, explosive or toxic work processes. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Semi-preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>Yes</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/16&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>PEEK / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>3 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>2 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>50 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>30 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/semipreparativeuvflowcell-a4047/">Semi-preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Semi-preparative High Temperature UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/semipreparativehightemperatureuvflowcell/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 08 Mar 2018 12:20:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/semipreparativehightemperatureuvflowcell/</guid>

					<description><![CDATA[<p>1/16"  2ul/10mm   SS      50ml/mn  HT  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/semipreparativehightemperatureuvflowcell/">Semi-preparative High Temperature UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/16&#8243; Fiber Optics Version</p>
<p>This stainless steel semi-preparative UV flow cell with fiber optic connectors is distinguished by its resistence to high temperatures and its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. With the aid of high temperature fiber optic cables, this flow cell can be separated spatially from the detector and placed inside an oven. This configuration can withstand temperature of up to 85 °C. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Semi-preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/16&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>3 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>2 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>50 ml/min</td>
</tr>
<tr>
<th>Temperature range</th>
<td>Up to 85 °C</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>300 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/semipreparativehightemperatureuvflowcell/">Semi-preparative High Temperature UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Semi-preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/semipreparativeuvflowcell-a4044/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 08 Mar 2018 11:58:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/semipreparativeuvflowcell-a4044/</guid>

					<description><![CDATA[<p>1/16'   2ul/10mm   SS      50ml/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/semipreparativeuvflowcell-a4044/">Semi-preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/16&#8243; Fiber Optics Version</p>
<p>This stainless steel semi-preparative UV flow cell with fiber optic connectors is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. Fiber optic cables offer the possibility to separate the flow cell spatially from the detector and thus provides enhanced security for hazardous, explosive or toxic work processes. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Semi-preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/16&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>3 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>2 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>50 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>300 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/semipreparativeuvflowcell-a4044/">Semi-preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Semi-preparative KNAUER PressureProof UV Flow Cell Cartridge</title>
		<link>https://www.iconsci.com/shop/semipreparativeknauerpressureproofuvflowcellcartridge/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 08 Mar 2018 11:46:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/semipreparativeknauerpressureproofuvflowcellcartridge/</guid>

					<description><![CDATA[<p>1/16"  2ul/3mm  PEEK   100ml/mn</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/semipreparativeknauerpressureproofuvflowcellcartridge/">Semi-preparative KNAUER PressureProof UV Flow Cell Cartridge</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/16&#8243;</p>
<p>This bioinert semi-preparative flow cell cartridge is optimized for high flow HPLC and FPLC applications and features an increased pressure stability (up to 300 bar) and extended flow rate range (up to 100 ml/min). This flow cell is compatible with the following KNAUER detectors: AZURA DAD 6.1L, DAD 2.1L, MWD 2.1L.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Semi-preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>Yes</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>No</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/16&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Titanium/ quartz (SUPRASIL) / PEEK</td>
</tr>
<tr>
<th>Path length</th>
<td>3 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>2 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>100 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>300 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/semipreparativeknauerpressureproofuvflowcellcartridge/">Semi-preparative KNAUER PressureProof UV Flow Cell Cartridge</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Semi-preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/semipreparativeuvflowcell-a4045/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 08 Mar 2018 11:33:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/semipreparativeuvflowcell-a4045/</guid>

					<description><![CDATA[<p>1/16"  2ul/10mm  PEEK 50ml/mn</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/semipreparativeuvflowcell-a4045/">Semi-preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/16&#8243;</p>
<p>This bioinert semi-preparative UV flow cell is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. This flow cell is compatible with the following KNAUER detectors: AZURA UVD 2.1S, UVD 2.1L and Smartline 200, 2500, 2520 and 2600</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Semi-preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>Yes</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>No</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/16&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>PEEK / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>3 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>2 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>50 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>30 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/semipreparativeuvflowcell-a4045/">Semi-preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4079/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 15:33:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4079/</guid>

					<description><![CDATA[<p>1/8"  PEEK  1000ml/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4079/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/8&#8243; Fiber Optics Version</p>
<p>This bioinert preparative UV flow cell with fiber optic connectors is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. Fiber optic cables offer the possibility to separate the flow cell spatially from the detector and thus provides enhanced security for hazardous, explosive or toxic work processes. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>Yes</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/8&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>PEEK / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 / 1.25 / 2 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>1.7 / 4.3 / 6.8 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>1000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>100 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4079/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4078/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 15:15:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4078/</guid>

					<description><![CDATA[<p>1/8"  SS 1000ml/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4078/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/8&#8243; Fiber Optics Version</p>
<p>This stainless steel preparative UV flow cell with fiber optic connectors is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. Fiber optic cables offer the possibility to separate the flow cell spatially from the detector and thus provides enhanced security for hazardous, explosive or toxic work processes. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/8&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 / 1.25 / 2 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>1.7 / 4.3 / 6.8 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>1000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>200 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4078/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4067/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 15:09:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4067/</guid>

					<description><![CDATA[<p>1/8"  PEEK  1000ml/mn</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4067/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/8&#8243;</p>
<p>This bioinert preparative UV flow cell is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. This flow cell is compatible with the following KNAUER detectors: AZURA UVD 2.1S, UVD 2.1L and Smartline 200, 2500, 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>Yes</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>No</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/8&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>PEEK / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 / 1.25 / 2 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>1.7 / 4.3 / 6.8 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>1000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>100 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4067/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4066/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 15:06:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4066/</guid>

					<description><![CDATA[<p>1/8"  SS  1000ml/mn</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4066/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/8&#8243;</p>
<p>This stainless steel preparative UV flow cell is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. This flow cell is compatible with the following KNAUER detectors: AZURA UVD 2.1S, UVD 2.1L and Smartline 200, 2500, 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>No</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/8&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 / 1.25 / 2 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>1.7 / 4.3 / 6.8 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>1000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>200 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4066/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4096/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 15:03:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4096/</guid>

					<description><![CDATA[<p>1/16"  PEEK  250ml/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4096/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/16&#8243; Fiber Optics Version</p>
<p>This bioinert preparative UV flow cell with fiber optic connectors is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. Fiber optic cables offer the possibility to separate the flow cell spatially from the detector and thus provides enhanced security for hazardous, explosive or toxic work processes. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>Yes</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/16&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>PEEK / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>3 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>250 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>100 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4096/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4095/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 15:00:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4095/</guid>

					<description><![CDATA[<p>1/16"  PEEK  250ml/mn</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4095/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/16&#8243;</p>
<p>This bioinert preparative UV flow cell is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. This flow cell is compatible with the following KNAUER detectors: AZURA UVD 2.1S, UVD 2.1L and Smartline 200, 2500, 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>Yes</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>No</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/16&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>PEEK / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>3 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>250 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>100 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4095/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4089/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 14:50:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4089/</guid>

					<description><![CDATA[<p>1/16"  SS  250ml/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4089/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/16&#8243; Fiber Optics Version</p>
<p>This stainless steel preparative UV flow cell with fiber optic connectors is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. Fiber optic cables offer the possibility to separate the flow cell spatially from the detector and thus provides enhanced security for hazardous, explosive or toxic work processes. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/16&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>3 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>250 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>200 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4089/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4069/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 14:44:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4069/</guid>

					<description><![CDATA[<p>1/16"  SS  250ml/mn</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4069/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/16&#8243;</p>
<p>This stainless steel preparative UV flow cell is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. This flow cell is compatible with the following KNAUER detectors: AZURA UVD 2.1S, UVD 2.1L and Smartline 200, 2500, 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>No</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/16&#8221;</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>3 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>250 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>200 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4069/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4155/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 12:05:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4155/</guid>

					<description><![CDATA[<p>3/4"  SS TRI-CLAMP 10L/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4155/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>3/4&#8243; TRI-Clamp</p>
<p>This stainless steel preparative UV flow cell is optimized for high flow applications. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600. Delivery includes a surface roughness certificate, inspection certificate 3.1 according to EN 10204, electropolishing certificate and a FDA certificate of conformity.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>3/4&#8221; (TRI-Clamp)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 / 1.25 / 2 mm</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>&gt; 10000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>80 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4155/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4154-1/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 12:01:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4154-1/</guid>

					<description><![CDATA[<p>3/8"  PEEK  TRI-CLAMP  10L/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4154-1/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>3/8&#8243; TRI-Clamp</p>
<p>This bioinert preparative UV flow cell is optimized for high flow applications. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>Yes</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>3/8&#8221; (TRI-Clamp)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>
<p>PEEK / quartz (SUPRASIL) / PTFE</p>
</td>
</tr>
<tr>
<th>Path length</th>
<td>10 mm</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>&gt; 10000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>10 bar</td>
</tr>
<tr>
<th>Note</th>
<td>inner diameter 10 mm, total lenght of the cell 102 mm</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4154-1/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4154/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 11:57:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4154/</guid>

					<description><![CDATA[<p>1/2"  SS TRI-CLAMP  10L/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4154/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/2&#8243; TRI-Clamp</p>
<p>This stainless steel preparative UV flow cell is optimized for high flow applications. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600. Delivery includes a surface roughness certificate, inspection certificate 3.1 according to EN 10204, electropolishing certificate and a FDA certificate of conformity.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/2&#8221; (TRI-Clamp)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 / 1.25 / 2 mm</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>&gt; 10000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>80 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4154/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4153/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 11:51:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4153/</guid>

					<description><![CDATA[<p>1/4" SS TRI-CLAMP  10L/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4153/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/4&#8243; TRI-Clamp</p>
<p>This stainless steel preparative UV flow cell is optimized for high flow applications. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600. Delivery includes a surface roughness certificate, inspection certificate 3.1 according to EN 10204, electropolishing certificate and a FDA certificate of conformity.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/4&#8221; (TRI-Clamp)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 / 1.25 / 2 mm</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>10000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>80 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4153/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4152-1/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 11:48:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4152-1/</guid>

					<description><![CDATA[<p>3/8" PEEK TRI-CLAMP 10L/mn F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4152-1/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>3/8&#8243; TRI-Clamp</p>
<p>This bioinert preparative UV flow cell is optimized for high flow applications. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>Yes</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>3/8&#8221; (TRI-Clamp)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>PEEK / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>7 mm</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>&gt; 10000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>10 bar</td>
</tr>
<tr>
<th>Note</th>
<td>inner diameter 7 mm, total lenght of the cell 102 mm</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4152-1/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4152/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 11:34:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4152/</guid>

					<description><![CDATA[<p>3/8"  SS  TRI-CLAMP  10L/mn  F.O.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4152/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>3/8&#8243; TRI-Clamp</p>
<p>This stainless steel preparative UV flow cell is optimized for high flow applications. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600. Delivery includes a surface roughness certificate, inspection certificate 3.1 according to EN 10204, electropolishing certificate and a FDA certificate of conformity.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>3/8&#8221; (TRI-Clamp)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 / 1.25 / 2 mm</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>&gt; 10000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>80 bar</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4152/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Preparative UV Flow Cell</title>
		<link>https://www.iconsci.com/shop/preparativeuvflowcell-a4081v2/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 11:30:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/preparativeuvflowcell-a4081v2/</guid>

					<description><![CDATA[<p>1/4" SS 10L/mn F.O. straight tubes</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/preparativeuvflowcell-a4081v2/">Preparative UV Flow Cell</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1/4&#8243; Fiber Optics Version</p>
<p>This stainless steel preparative UV flow cell with fiber optic connectors is distinguished by its robust and long-life design. The flow cell can be easily dismantled allowing optical components to be cleaned and replaced. Fiber optic cables offer the possibility to separate the flow cell spatially from the detector and thus provides enhanced security for hazardous, explosive or toxic work processes. This flow cell is compatible with the following KNAUER fiber optic version detectors: AZURA UVD 2.1S, UVD 2.1L, DAD 6.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 and 2600.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Flow cell</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow cell type</th>
<td>Preparative UV flow cell</td>
</tr>
<tr>
<th>Biocompatible</th>
<td>No</td>
</tr>
<tr>
<th>Fiber optics version</th>
<td>Yes</td>
</tr>
<tr>
<th>Capillary connection</th>
<td>1/4&#8221; (straight connections)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Stainless steel / quartz (SUPRASIL) / PTFE</td>
</tr>
<tr>
<th>Path length</th>
<td>0.5 / 1.25 / 2 mm</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>1.7 / 4.3 / 6.8 µl</td>
</tr>
<tr>
<th>Maximum flow rate</th>
<td>10000 ml/min</td>
</tr>
<tr>
<th>Maximum pressure</th>
<td>200 bar</td>
</tr>
</tbody>
</table>
</div>