<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Multiple Wavelength Detectors &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/uv-detectors-flow-cells/multiple-wavelength-detectors/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Wed, 04 Feb 2026 20:16:24 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>Multiple Wavelength Detectors &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ANSER MWD-2001F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2001f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 20:08:32 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4988</guid>

					<description><![CDATA[<p>ANSER MWD-2001F Technical specifications Instrument type Double-beam photometer Light source D2 Lamp, Fiber Optics Wavelength range 190 &#8211; 420 nm [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2001f/">ANSER MWD-2001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2001F</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 Lamp, Fiber Optics</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote Fiber Optic connectors</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2001f/">ANSER MWD-2001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-2001</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2001/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 20:06:49 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4987</guid>

					<description><![CDATA[<p>ANSER MWD-2001 Technical specifications Instrument type Double-beam photometer Light source D2 Lamp Wavelength range 190 &#8211; 420 nm Number of [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2001/">ANSER MWD-2001</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2001</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 Lamp</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Accepts standard flow cells</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2001/">ANSER MWD-2001</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1001F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-1001f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 20:04:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4986</guid>

					<description><![CDATA[<p>ANSER MWD-1001F Technical specifications Instrument type Double-beam photometer Light source D2 Lamp, Fiber Optic Wavelength range 190 &#8211; 420 nm [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1001f/">ANSER MWD-1001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-1001F</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 Lamp, Fiber Optic</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote Fiber Optic connectors</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1001f/">ANSER MWD-1001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1001</title>
		<link>https://www.iconsci.com/shop/anser-mwd-1001/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 20:02:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4985</guid>

					<description><![CDATA[<p>ANSER MWD-1001 Technical specifications Instrument type Double-beam photometer Light source D2 Lamp Wavelength range 190 &#8211; 420 nm Number of [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1001/">ANSER MWD-1001</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-1001</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 Lamp</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Accepts standard flow cells</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1001/">ANSER MWD-1001</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1002F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-1002f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 19:53:10 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4983</guid>

					<description><![CDATA[<p>ANSER MWD-1002F Technical specifications Instrument type Double-beam photometer Light source D2 &#38; Tungsten Halogen, Fiber Optics Wavelength range 190 &#8211; [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1002f/">ANSER MWD-1002F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-1002F</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 &amp; Tungsten Halogen, Fiber Optics</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote, fiber optic connectors</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1002f/">ANSER MWD-1002F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1002</title>
		<link>https://www.iconsci.com/shop/anser-mwd-1002/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 19:51:36 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4982</guid>

					<description><![CDATA[<p>ANSER MWD-1002 Technical specifications Instrument type Double-beam photometer Light source D2 &#38; Tungsten Halogen Wavelength range 190 &#8211; 750 nm [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1002/">ANSER MWD-1002</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-1002</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 &amp; Tungsten Halogen</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Accepts standard flow cells</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1002/">ANSER MWD-1002</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-2002</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2002-2/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 19:49:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4981</guid>

					<description><![CDATA[<p>ANSER MWD-2002 Technical specifications Instrument type Double-beam photometer Light source D2 &#38; Tungsten Halogen Wavelength range 190 &#8211; 750 nm [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2002-2/">ANSER MWD-2002</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2002</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 &amp; Tungsten Halogen</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Accepts standard flow cells</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2002-2/">ANSER MWD-2002</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1003F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-1003f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 19:22:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4980</guid>

					<description><![CDATA[<p>Technical specifications Instrument type Double-beam photometer Light source Xenon flash lamp, Fiber Optic Wavelength range 190 &#8211; 750 nm Number [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1003f/">ANSER MWD-1003F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Xenon flash lamp, Fiber Optic</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote, light fiber optics connectors</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">95 x 160 x 280 mm / 3.75 x 6.5 x 11.0 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1003f/">ANSER MWD-1003F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-2002F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2002f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 16:28:50 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4978</guid>

					<description><![CDATA[<p>ANSER MWD-2002F Technical specifications Instrument type Double-beam photometer Light source D2 &#38; Tungsten Halogen, Fiber Optics Wavelength range 190 &#8211; [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2002f/">ANSER MWD-2002F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2002F</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 &amp; Tungsten Halogen, Fiber Optics</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote, fiber optic connectors</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2002f/">ANSER MWD-2002F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-2003F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2003f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 16:23:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4976</guid>

					<description><![CDATA[<p>ANSER MWD-2003F Technical specifications Instrument type Double-beam photometer Light source Xenon flash lamp, Fiber Optics Wavelength range 190 &#8211; 750 [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2003f/">ANSER MWD-2003F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2003F</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Xenon flash lamp, Fiber Optics</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote, fiber optic connectors</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">95 x 160 x 280 mm / 3.75 x 6.5 x 11.0 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2003f/">ANSER MWD-2003F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-2003</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2003/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 28 Sep 2022 17:31:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4802</guid>

					<description><![CDATA[<p>ANSER MWD-2003 Technical specifications Instrument type Double-beam photometer Light source Xenon flash lamp Wavelength range 190 &#8211; 750 nm Number [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2003/">ANSER MWD-2003</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2003</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Xenon flash lamp</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Accepts standard flow cells</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">95 x 160 x 280 mm / 3.75 x 6.5 x 11.0 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2003/">ANSER MWD-2003</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1003</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2002/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 28 Sep 2022 17:30:32 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4800</guid>

					<description><![CDATA[<p>ANSER MWD-1003 Technical specifications Instrument type Double-beam photometer Light source Xenon flash lamp Wavelength range 190 &#8211; 750 nm Number [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2002/">ANSER MWD-1003</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-1003</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Xenon flash lamp</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Accepts standard flow cells</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">95 x 160 x 280 mm / 3.75 x 6.5 x 11.0 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2002/">ANSER MWD-1003</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>BlueShadow UV/VIS MWD 50D</title>
		<link>https://www.iconsci.com/shop/blueshadowuvvismwd50d/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Tue, 20 Feb 2018 18:11:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/blueshadowuvvismwd50d/</guid>

					<description><![CDATA[<p>190-750nm, multiwavelength detector</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/blueshadowuvvismwd50d/">BlueShadow UV/VIS MWD 50D</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Variable multiple wavelengths</p>
<p>The BlueShadow 50D offers high sensitivity and baseline stability for HPLC applications including fast LC methods. With its high speed scanning design, up to four different wavelengths can be monitored simultaneously while acquiring spectral data from 190 to 750 nm. Its remarkable values for noise, drift, and linearity are achieved through smart optical bench technology and the use of optimized components. The detector comes with an installed deuterium lamp which covers a wavelength range from 190 to 750 nm. This detector can be controlled with OpenLab® EZChrom Edition, ClarityChrom® software, as well as via the integrated display (stand-alone operation), via LAN, via RS-232, or through analog input/output. Due to a smart design the flow cell is easily accessible and can be changed very quickly. A wide range of flow cells is available for practically any LC application, including micro flow cells for flow rates up to 10 μl/min and flow cells for preparative HPLC up to 10 l/min.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Detection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Detector type</th>
<td>Variable multiwavelength detector</td>
</tr>
<tr>
<th>Detection channels</th>
<td>4</td>
</tr>
<tr>
<th>Light source</th>
<td>Deuterium (D²) lamp with integrated GLP chip</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>190 &#8211; 750 nm</td>
</tr>
<tr>
<th>Spectral bandwidth</th>
<td>6 nm at H<sub>α</sub> line (FWHM)</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.0 nm (verification with integrated holmium oxide filter)</td>
</tr>
<tr>
<th>Wavelength precision</th>
<td>0.4 nm (ASTM E275-93)</td>
</tr>
<tr>
<th>Noise</th>
<td>± 0.75 x 10<sup>-5</sup> AU at 254 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Drift</th>
<td>1.5 x 10<sup>-4</sup> AU/h at 254 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Linearity</th>
<td>&gt; 2.2 AU at 270 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Maximum data rate</th>
<td>50 Hz (LAN) 1 channel/20 Hz (Analog) 1 channel/10 Hz (RS–232) 1 channel</td>
</tr>
<tr>
<th>Flow cell</th>
<td>Not included</td>
</tr>
<tr>
<th>Time constants</th>
<td>0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s</td>
</tr>
<tr>
<th>Integration time</th>
<td>Automatic</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>Error (IN), Start (IN), Autozero, 0 &#8211; 10 V Analog IN</td>
</tr>
<tr>
<th>Outputs</th>
<td>Events 1 &#8211; 3, + 5 V, 24 V Value</td>
</tr>
<tr>
<th>Analog outputs</th>
<td>2 x 0 &#8211; 5 V scalable, 20 bit, offset adjustable</td>
</tr>
<tr>
<th>Control</th>
<td>Digital: LAN-DHCP, RS-232, remote connector/Analog: wavelength control/Manual: touchpad</td>
</tr>
<tr>
<th>Programming</th>
<td>Timed: wavelengths, events, fraction valve, links, wake up (program, link); /9 programs, 50 program lines</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>GLP</th>
<td>Detailed report including lamp recognition, operating hours, lamp(s) operating hours, /step motor operating hours, number of lamp ignitions</td>
</tr>
<tr>
<th>Display</th>
<td>Touchscreen TFT 2.4&#8242;</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>Temperature range: 4 – 40 °C; 39.2 – 104 °F, Humidity: below 90 % noncondensing</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 – 240 V, 50 – 60 Hz, 75 W</td>
</tr>
<tr>
<th>Dimensions</th>
<td>242 x 169 x 399 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>5.3 kg</td>
</tr>
</tbody>
</table>
</div>
<div class="other">
<h2 class="table-module__header">Other</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Optional accessories</th>
<td>Halogen lamp</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v7654_blueshadow_50d_user-manual_en.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v7654_blueshadow_50d_user-manual_en.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">BlueShadow Detector 50D User Manual EN (V7654A)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v7654_blueshadow_50d_user-manual_en.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v7654_blueshadow_50d_benutzerhandbuch_de.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v7654_blueshadow_50d_benutzerhandbuch_de.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">BlueShadow Detector 50D Benutzerhandbuch DE (V7654)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v7654_blueshadow_50d_benutzerhandbuch_de.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/blueshadowuvvismwd50d/">BlueShadow UV/VIS MWD 50D</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AZURA Detector MWD 2.1L</title>
		<link>https://www.iconsci.com/shop/azuradetectormwd21l/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Tue, 20 Feb 2018 17:39:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/azuradetectormwd21l/</guid>

					<description><![CDATA[<p>190 - 700 nm, multiwavelength detector</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azuradetectormwd21l/">AZURA Detector MWD 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Multiwavelength detector</p>
<p>The AZURA MWD 2.1L is an 8 channel, sensitive multiwavelength detector combining high performance with easy handling at an affordable price. A wide range of easily exchangeable cartridge flow cells make this device the right choice for fast, standard analytical, semi-preparative and preparative separations with bio-inert or stainless steel wetted parts. State-of-the-art total reflection flow cells (LightGuide technology) are available for this device providing maximum light throughput (due to total internal reflection) with minimal peak dispersion (due to the small cell volume) to guarantee an optimized S/N ratio. An optional fiber optics adapter offers the possibility to separate the flow cell spatially from the device and thus provides enhanced security for hazardous, explosive or toxic work processes, as well as protecting the device from leakages at high flow rates. The newly developed optical unit and intelligent temperature management ensure for maximum sensitivity combined with minimal baseline drift. Furthermore, easy frontal access and improved safety features enable effortless lamp replacement. This eases maintenance and guarantees short downtimes. This device is also easily upgradable to a diode array detector. The MWD 2.1L comes installed with a deuterium lamp which covers a wavelength range from 190 to 700 nm. This detector can be controlled with OpenLab® EZChrom, ClarityChrom®, Chromeleon® and PurityChrom® software, as well as from the Mobile Control software (stand-alone operation), via LAN or through analog input/output, allowing it to be integrated into almost any LC system.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Detection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Detector type</th>
<td>Variable multiwavelength detector</td>
</tr>
<tr>
<th>Detection channels</th>
<td>8 (Digital)/4 (Analog)</td>
</tr>
<tr>
<th>Light source</th>
<td>Deuterium (D²) lamp with integrated GLP chip</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>190 &#8211; 700 nm</td>
</tr>
<tr>
<th>Spectral bandwidth</th>
<td>&lt; 10 nm at H<sub>α</sub> line (FWHM) /Note: digital bandwidth 1 &#8211; 32 nm</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 1 nm</td>
</tr>
<tr>
<th>Noise</th>
<td>± 5 µAU at 254 nm</td>
</tr>
<tr>
<th>Drift</th>
<td>400 µAU/h at 254 nm</td>
</tr>
<tr>
<th>Linearity</th>
<td>&gt; 2.0 AU at 274 nm</td>
</tr>
<tr>
<th>Maximum data rate</th>
<td>100 Hz (LAN)/12.5 Hz (analog)</td>
</tr>
<tr>
<th>Flow cell</th>
<td>Not included (see Accessories / Spare parts)</td>
</tr>
<tr>
<th>Time constants</th>
<td>0.00 / 0.01 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s</td>
</tr>
<tr>
<th>Integration time</th>
<td>Automatic</td>
</tr>
<tr>
<th>Wavelength verification</th>
<td>Internal holmium filter and deuterium lines</td>
</tr>
<tr>
<th>Leak sensor</th>
<td>Yes</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>Error (IN), Start (IN), Autozero</td>
</tr>
<tr>
<th>Outputs</th>
<td>Events 1 &#8211; 2 (Relay and TTL compatible, respectively), Error (OUT), + 5 V, Valve + 24 V, Valve (OUT)</td>
</tr>
<tr>
<th>Analog outputs</th>
<td>4 x 0 &#8211; 5 V, 16 bit, offset adjustable</td>
</tr>
<tr>
<th>Control</th>
<td>Mobile Control, software, event control, analog, terminal protocol</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN (RJ-45), USB (service only), multi-pin connector, analog (RCA cinch connector)</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>GLP</th>
<td>Detailed report including lamp recognition, operating hours, /lamp operating hours, number of lamp ignitions</td>
</tr>
<tr>
<th>Display</th>
<td>Optional Mobile Control</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>Temperature range: 4 &#8211; 40 °C, 39.2 &#8211; 104 °F, Humidity: below 90 % noncondensing</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 – 240 V, 50 – 60 Hz, 75 W</td>
</tr>
<tr>
<th>Dimensions</th>
<td>361 x 158 x 523 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>12.2 kg</td>
</tr>
</tbody>
</table>
</div>
<div class="other">
<h2 class="table-module__header">Other</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Note</th>
<td>Flow cells are not included and must be ordered separately (see Accessories / Spare parts)</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v6700_azura_dad-mwd_benutzerhandbuch_de.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v6700_azura_dad-mwd_benutzerhandbuch_de.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Detektor DAD 6.1L, DAD 2.1L, MWD 2.1L Benutzerhandbuch DE (V6700)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.6 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v6700_azura_dad-mwd_benutzerhandbuch_de.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v7646_blueshadow_40d_user-manual_en.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v7646_blueshadow_40d_user-manual_en.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Detector DAD 6.1L, DAD 2.1L, MWD 2.1L User Manual EN (V6700)</h2>
<p class="list-download__subline">
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.6 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v6700_azura_dad-mwd_user_manual_en.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_softwares.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_softwares.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software_v1663.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azuradetectormwd21l/">AZURA Detector MWD 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Multi Wavelength UV Detector for Liquid Chromatography and Process Technology</title>
		<link>https://www.iconsci.com/shop/blueshadowuvvisdetector40dfiberoptics/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 19 Feb 2018 19:07:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/blueshadowuvvisdetector40dfiberoptics/</guid>

					<description><![CDATA[<p>190-750nm, variable single wavelength UV/VIS detector with fiber optic connectors</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/blueshadowuvvisdetector40dfiberoptics/">Multi Wavelength UV Detector for Liquid Chromatography and Process Technology</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The BlueShadow 50D offers high sensitivity and baseline stability for HPLC applications including fast LC methods. With its high speed scanning design, up to four different wavelengths can be monitored simultaneously while acquiring spectral data from 190 to 750 nm. Its remarkable values for noise, drift, and linearity are achieved through smart optical bench technology and the use of optimized components. The detector comes with an installed deuterium lamp which covers a wavelength range from 190 to 750 nm. This detector can be controlled with OpenLab<sup>®</sup> EZChrom Edition, ClarityChrom<sup>®</sup> software, as well as via the integrated display (stand-alone operation), via LAN, via RS-232, or through analog input/output. Due to a smart design the flow cell is easily accessible and can be changed very quickly. A wide range of flow cells is available for practically any LC application, including micro flow cells for flow rates up to 10 μl/min and flow cells for preparative HPLC up to 10 l/min.</p>
<p>&nbsp;</p>
<p style="text-align: center;"><strong>Technical Data</strong></p>
<section class="table-module">
<div class="container">
<div class="row clearfix">
<h3 class="table-module__header">Detection</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>Detector type</th>
<td>Variable multiwavelength detector</td>
</tr>
<tr>
<th>Detection channels</th>
<td>4</td>
</tr>
<tr>
<th>Light source</th>
<td>Deuterium (D<sub>2</sub>) lamp with integrated GLP chip</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>190 &#8211; 750 nm</td>
</tr>
<tr>
<th>Spectral bandwidth</th>
<td>6 nm at H<sub>α</sub> line (FWHM)</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 1.5 nm (verification with integrated holmium oxide filter)</td>
</tr>
<tr>
<th>Wavelength precision</th>
<td>0.4 nm (ASTM E275-93)</td>
</tr>
<tr>
<th>Noise</th>
<td>± 7.5 µAU at 254 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Drift</th>
<td>200 µAU/h at 254 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Linearity</th>
<td>&gt; 2.8 AU at 270 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Maximum data rate</th>
<td>50 Hz (LAN) 1 channel/20 Hz (Analog) 1 channel/10 Hz (RS–232) 1 channel</td>
</tr>
<tr>
<th>Flow cell</th>
<td>Not included</td>
</tr>
<tr>
<th>Time constants</th>
<td>0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s</td>
</tr>
<tr>
<th>Integration time</th>
<td>Automatic</td>
</tr>
</tbody>
</table>
</div>
<div class="row clearfix">
<h3 class="table-module__header">Communication</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>Error (IN), Start (IN), Autozero, 0 &#8211; 10 V Analog IN</td>
</tr>
<tr>
<th>Outputs</th>
<td>Events 1 &#8211; 3, + 5 V, 24 V Value</td>
</tr>
<tr>
<th>Analog outputs</th>
<td>2 x 0 &#8211; 5 V scalable, 20 bit, offset adjustable</td>
</tr>
<tr>
<th>Control</th>
<td>Digital: LAN-DHCP, RS-232, remote connector/Analog: wavelength control/Manual: keypad</td>
</tr>
<tr>
<th>Programming</th>
<td>Timed: wavelengths, events, fraction valve, links, wake up (program, link); /9 programs, 50 program lines</td>
</tr>
</tbody>
</table>
</div>
<div class="row clearfix">
<h3 class="table-module__header">Technical parameters</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>GLP</th>
<td>Detailed report including lamp recognition, operating hours, lamp(s) operating hours, /step motor operating hours, number of lamp ignitions</td>
</tr>
<tr>
<th>Display</th>
<td>Matrix display with keypad</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>Temperature range: 4 – 40 °C; 39.2 – 104 °F, Humidity: below 90 % non condensing</td>
</tr>
</tbody>
</table>
</div>
<div class="row clearfix">
<h3 class="table-module__header">General</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 – 240 V, 50 – 60 Hz, 75 W</td>
</tr>
<tr>
<th>Dimensions</th>
<td>242 x 169 x 399 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>5.3 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</section>
<section id="related-product-grid-static" data-init-list="true" data-per-page="4">
<div class="container"></div>
</section>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/blueshadowuvvisdetector40dfiberoptics/">Multi Wavelength UV Detector for Liquid Chromatography and Process Technology</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dual Lamp Stand Alone Multi Wavelength UV Detector for Liquid Chromatography and Process Technology</title>
		<link>https://www.iconsci.com/shop/blueshadowuvvisdetector40d/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 19 Feb 2018 18:59:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/blueshadowuvvisdetector40d/</guid>

					<description><![CDATA[<p>190-750nm, variable single wavelength UV/VIS detector</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/blueshadowuvvisdetector40d/">Dual Lamp Stand Alone Multi Wavelength UV Detector for Liquid Chromatography and Process Technology</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The BlueShadow 50D offers high sensitivity and baseline stability for HPLC applications including fast LC methods. With its high speed scanning design, up to four different wavelengths can be monitored simultaneously while acquiring spectral data from 190 to 900 nm. Its remarkable values for noise, drift, and linearity are achieved through smart optical bench technology and the use of optimized components. The detector comes with an installed deuterium lamp  and an installed halogen lamp which are covering a wavelength range from 190 to 900 nm. This detector can be controlled with OpenLab<sup>®</sup> EZChrom Edition, ClarityChrom<sup>®</sup> software, as well as via the integrated display (stand-alone operation), via LAN, via RS-232, or through analog input/output. Due to a smart design the flow cell is easily accessible and can be changed very quickly. A wide range of flow cells is available for practically any LC application, including micro flow cells for flow rates up to 10 μl/min and flow cells for preparative HPLC up to 10 l/min.</p>
<h1 style="text-align: center;"><strong>Technical Data</strong></h1>
<section class="table-module">
<div class="container">
<div class="row clearfix">
<h3 class="table-module__header">Detection</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>Detector type</th>
<td>Variable multiwavelength detector</td>
</tr>
<tr>
<th>Detection channels</th>
<td>4</td>
</tr>
<tr>
<th>Light source</th>
<td>Deuterium (D<sub>2</sub>) lamp and halogen lamp with integrated GLP chip</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>190 &#8211; 900 nm</td>
</tr>
<tr>
<th>Spectral bandwidth</th>
<td>6 nm at H<sub>α</sub> line (FWHM)</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 1.5 nm (verification with integrated holmium oxide filter)</td>
</tr>
<tr>
<th>Wavelength precision</th>
<td>0.4 nm (ASTM E275-93)</td>
</tr>
<tr>
<th>Noise</th>
<td>± 7.5 µAU at 254 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Drift</th>
<td>200 µAU/h at 254 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Linearity</th>
<td>&gt; 2.8 AU at 270 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Maximum data rate</th>
<td>50 Hz (LAN) 1 channel/20 Hz (Analog) 1 channel/10 Hz (RS–232) 1 channel</td>
</tr>
<tr>
<th>Flow cell</th>
<td>Not included</td>
</tr>
<tr>
<th>Time constants</th>
<td>0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s</td>
</tr>
<tr>
<th>Integration time</th>
<td>Automatic</td>
</tr>
</tbody>
</table>
</div>
<div class="row clearfix">
<h3 class="table-module__header">Communication</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>Error (IN), Start (IN), Autozero, 0 &#8211; 10 V Analog IN</td>
</tr>
<tr>
<th>Outputs</th>
<td>Events 1 &#8211; 3, + 5 V, 24 V Value</td>
</tr>
<tr>
<th>Analog outputs</th>
<td>2 x 0 &#8211; 5 V scalable, 20 bit, offset adjustable</td>
</tr>
<tr>
<th>Control</th>
<td>Digital: LAN-DHCP, RS-232, remote connector/Analog: wavelength control/Manual: keypad</td>
</tr>
<tr>
<th>Programming</th>
<td>Timed: wavelengths, events, fraction valve, links, wake up (program, link); /9 programs, 50 program lines</td>
</tr>
</tbody>
</table>
</div>
<div class="row clearfix">
<h3 class="table-module__header">Technical parameters</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>GLP</th>
<td>Detailed report including lamp recognition, operating hours, lamp(s) operating hours, /step motor operating hours, number of lamp ignitions</td>
</tr>
<tr>
<th>Display</th>
<td>Matrix display with keypad</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>Temperature range: 4 – 40 °C; 39.2 – 104 °F, Humidity: below 90 % noncondensing</td>
</tr>
</tbody>
</table>
</div>
<div class="row clearfix">
<h3 class="table-module__header">General</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 – 240 V, 50 – 60 Hz, 75 W</td>
</tr>
<tr>
<th>Dimensions</th>
<td>242 x 169 x 399 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>5.3 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</section>
<section id="related-product-grid-static" data-init-list="true" data-per-page="4">
<div class="container"></div>
</section>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/blueshadowuvvisdetector40d/">Dual Lamp Stand Alone Multi Wavelength UV Detector for Liquid Chromatography and Process Technology</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>