<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Conductivity and pH Monitors &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/conductivity-and-ph-monitors/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Fri, 07 Feb 2025 14:54:21 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>Conductivity and pH Monitors &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ANSER Conductivity monitor with pH &#8211; monitor option</title>
		<link>https://www.iconsci.com/shop/anser-conductivity-monitor-with-ph-monitor-option/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 26 Apr 2023 13:53:58 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4848</guid>

					<description><![CDATA[<p>ANSER Conductivity monitor with pH-monitor option   Specifications Model CDM-3000 Conductivity reading range 0.0001 – 1000.0 mS/cm Accuracy ± 0.01 [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-conductivity-monitor-with-ph-monitor-option/">ANSER Conductivity monitor with pH &#8211; monitor option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400;"><strong>ANSER Conductivity monitor with pH-monitor option</strong></p>
<p style="font-weight: 400;"><strong> </strong></p>
<p style="font-weight: 400;"><strong>Specifications</strong></p>
<table style="font-weight: 400;">
<tbody>
<tr>
<td><strong>Model</strong></td>
<td width="253"><strong>CDM-3000</strong></td>
</tr>
<tr>
<td><strong>Conductivity reading range</strong></td>
<td width="253">0.0001 – 1000.0 mS/cm</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
<td width="253">± 0.01 mS/cm or ± 2%, whichever is greater,</p>
<p>within 0.1 – 300 mS/cm range</td>
</tr>
<tr>
<td><strong>Operating pressure</strong></td>
<td width="253">0 &#8211; 10 MPa</td>
</tr>
<tr>
<td><strong>Temperature measurement range</strong></td>
<td width="253">0-100 °C</td>
</tr>
<tr>
<td><strong>Temperature measurement accuracy</strong></td>
<td width="253">± 0.5 °C within 4 – 45 °C</td>
</tr>
<tr>
<td><strong>pH measurement range</strong></td>
<td width="253">0 &#8211; 14 pH</td>
</tr>
<tr>
<td><strong>pH measurement accuracy</strong></td>
<td width="253">± 0.05 pH within 2 – 12 pH</td>
</tr>
<tr>
<td><strong>pH-monitor operating pressure</strong></td>
<td width="253">0 – 0.5 MPa</td>
</tr>
<tr>
<td><strong>pH flow cell volume</strong></td>
<td width="253">10 µl</td>
</tr>
<tr>
<td><strong>Wetted materials</strong></td>
<td width="253">Titanium (conductivity, reference electrodes)</p>
<p>Glass (pH electrode)</p>
<p>PEEK (flow cell bodies)</td>
</tr>
<tr>
<td><strong>Stand-alone operation</strong></td>
<td width="253">4” LCD with touch panel</td>
</tr>
<tr>
<td><strong>Remote operation</strong></td>
<td width="253">Conductivity or pH signal, analogue output 0..+2,5 V</td>
</tr>
<tr>
<td><strong>Communication</strong></td>
<td width="253">LAN 10/100 Mbit/s</p>
<p>USB 2.0</td>
</tr>
<tr>
<td><strong>Power requirements</strong></td>
<td width="253">External power supply, 24 Vdc, 1.0 A max.</td>
</tr>
<tr>
<td><strong>Operating temperature</strong></td>
<td width="253">4 &#8211; 45 °C / 41 &#8211; 95 °F</td>
</tr>
<tr>
<td><strong>Humidity</strong></td>
<td width="253">0 &#8211; 90 %, non-condensing</td>
</tr>
<tr>
<td><strong>Weight without power supply</strong></td>
<td width="253">1 kg / 2.2 lb</td>
</tr>
<tr>
<td><strong>Size without pH-module</strong></td>
<td width="253">130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in. (W x H x D)</td>
</tr>
<tr>
<td><strong>Size with pH-module</strong></td>
<td width="253">180 x 200 x 320 mm / 7.1 x 7.9 x 13.7 in. (W x H x D)</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-conductivity-monitor-with-ph-monitor-option/">ANSER Conductivity monitor with pH &#8211; monitor option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AZURA CM 2.1S</title>
		<link>https://www.iconsci.com/shop/azuracm21s/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 28 Feb 2018 14:30:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/azuracm21s/</guid>

					<description><![CDATA[<p>Conductivity monitor with optional pH measurement</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azuracm21s/">AZURA CM 2.1S</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Conductivity monitor with optional pH measurement</p>
<p>The AZURA CM 2.1S is a reliable conductivity monitor which is utilized in FPLC to follow salt gradients. Optionally pH values can be measured. Wetted parts are completely biocompatible. The contactless measurements of conductivity reduces the risk of carryover to a minimum. Two flow cells cover a flow rate up to either 10 ml/min or 100 ml/min and are optimized for low dead volume. Please order the conductivity flow cell and the pH measuring kit in addition to the CM 2.1S.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Detection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Detector type</th>
<td>Conductivity monitor</td>
</tr>
<tr>
<th>Measurement accuracy</th>
<td>Temperature sensor accuracy: ± 1.0 °C;Conductivity accuracy:</td>
</tr>
<tr>
<th>Measurement precision</th>
<td>Conductvity precision measured in range 0.1-300 mS/cm: &lt;2% of end value or ≤ 5 mS/cm of higher values pH precision +/-0.2 pH in temperature range 4-25°C</td>
</tr>
<tr>
<th>Measurement range</th>
<td>0.1 – 999mS/cm</td>
</tr>
<tr>
<th>pH measurement</th>
<td>2-12</td>
</tr>
<tr>
<th>Maximum data rate</th>
<td>5 Hz</td>
</tr>
<tr>
<th>Flow cell</th>
<td>10 ml or 100 ml</td>
</tr>
<tr>
<th>Supported electrodes</th>
<td>conductivity: automatic recognition pH: all pH electrodes with BNC connector (compatible) and available flow cell</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Analog outputs</th>
<td>2 channelsDAC 18 bitConductivity value pH Value (only for the stand-alone device)</td>
</tr>
<tr>
<th>Digital outputs</th>
<td>LAN; RS-232</td>
</tr>
</tbody>
</table>
</div>
<div class="technical">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>GLP</th>
<td>electronic Serial No.</td>
</tr>
<tr>
<th>Display</th>
<td>LCD, 2 x 8 characters</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>operating temperature: 4 to 35 °C, relative humidity: 45 to 85 %</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 – 240 V, 50 – 60 Hz, max. 20W</td>
</tr>
<tr>
<th>Dimensions</th>
<td>121 x 129 x 187mm (W x H x D)</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v6710_azura_cm_2.1s_benutzerhandbuch_de.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v6710_azura_cm_2.1s_benutzerhandbuch_de.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Leitfähigkeitsmonitor CM 2.1S Benutzerhandbuch DE (V6710)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">563.6 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v6710_azura_cm_2.1s_benutzerhandbuch_de.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v6710_azura_cm-21s_usermanual_en.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v6710_azura_cm-21s_usermanual_en.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Conductivity Monitor CM 2.1S User Manual EN (V6710)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">552.8 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v6710_azura_cm-21s_usermanual_en.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azuracm21s/">AZURA CM 2.1S</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>