<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Autosamplers &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/autosamplers/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Tue, 17 Nov 2020 23:34:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>Autosamplers &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Sykam Autosampler</title>
		<link>https://www.iconsci.com/shop/sykam-autosampler/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Tue, 17 Nov 2020 21:08:54 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4631</guid>

					<description><![CDATA[<p>This Autosampler is offered in different configurations . Choice of different sizes, from single rack, low-capacity to multi rack high [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/sykam-autosampler/">Sykam Autosampler</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>This Autosampler is offered in different configurations . Choice of different sizes, from single rack, low-capacity to multi rack high capacity. X,Y and Z axis can be individually adjusted to meet almost any size.</p>
<p>Standard configuration includes:</p>
<ul>
<li>2 vial racks with 60 vials per rack</li>
<li>Reagent vial holder (derivatization option)</li>
<li>Wash port (needle cleaning)</li>
<li>Injection valve with integrated injection port</li>
<li>100 I sample loop</li>
<li>Optional &#8211; sample rack heating/cooling module</li>
</ul>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/sykam-autosampler/">Sykam Autosampler</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>No Frills HPLC AUTOSAMPLER</title>
		<link>https://www.iconsci.com/shop/no-frills-hplc-autosampler/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Fri, 12 Apr 2019 11:39:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/no-frills-hplc-autosampler/</guid>

					<description><![CDATA[<p>Free software “HTA Autosampler Manager (Standard Version)“ is provided for PC control; upgrade to “HTA Autosampler Manager (CFR 21 Part 11 Version)“ should be purchased separately. PC is required for setup, service, method and sequence editing.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/no-frills-hplc-autosampler/">No Frills HPLC AUTOSAMPLER</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Load your samples and press the START button. The tray rotates and the arm with the needle is aligned on top of the first sample vial to be processed.<br />
The needle is inserted in the vial at the programmable depth where the sample is aspirated by the built-in pump in order to fill the loop. The injection valve is then moved to the inject position and the sample is delivered to the HPLC system. Then, by using the on-board solvents, the needle and the whole flow-path are cleaned before processing the next sample.</p>
<p><strong>HT1500L/</strong> – uses standard consumables<br />
– offers the capability to automate up to 45 samples. By supporting multiple racks – each of them removable – allows for continuous feeding and convenient operation.</p>
<h2 class="table-module__header">Easy-To-Operate</h2>
<p>Keypad operations enable simple automation of any existing HPLC and makes the autosampler easy to control by any chromatography software.<br />
HT1500L comes with HTA Autosampler Manager (Standard Version), our complimentary software control for autosampler programming. After setting your method once, just load samples and press START</p>
<h2 class="table-module__header">NO FRILLS</h2>
<p>Is your HPLC routine calling for automation? Look no further than the HT1500L; an autosampler designed for HPLC, fully equipped with powerful features.<br />
Unlike LC-MS, nanoLC and UHPLC systems the HPLC system requires few, essential features: excellent analytical performance, good sample capacity, and of course, uncompromised reliability, robustness and durability.<br />
We have designed the HT1500L with all essential features a cutting-edge HPLC system calls for, while eliminating anything unnecessary to keep your costs as a minimum. No frills. No compromise.</p>
<h2 class="table-module__header">No Compromise on Quality</h2>
<p>While we have struggled to achieve a low price, we haven’t made any compromise on quality.<br />
HT1500L has a strong commitment to quality that focuses on providing a real unattended experience: HT1500L will be your workhorse requiring very few or no attention from lab technicians. The materials have been picked up to provide longevity; the up-to-date technologies offer reliability that deserve a modern instrument while the design attests our care in details.</p>
<h1 class="headline">Technical Specifications</h1>
<div class="ginfo">
<h2 class="table-module__header">General features</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Sample capacity:</th>
<td>45 vials, 4ml (5 removable racks)</td>
</tr>
<tr>
<th>Solvent capacity:</th>
<td>5 vials, 40ml (1 removable rack)</td>
</tr>
<tr>
<th>Maintenance:</th>
<td>Preventive counters available</td>
</tr>
<tr>
<th>Electrical control:</th>
<td>USB and TTL</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>RSD:</th>
<td>≤ 0.25%</td>
</tr>
<tr>
<th>Linearity (r):</th>
<td>≥ 0.999</td>
</tr>
<tr>
<th>Carry over1:</th>
<td>≤ 0.01%</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Valve</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Type:</th>
<td>6-2</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Wash</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Mode:</th>
<td>every injection/sample/step pre &amp; post injection</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Filling</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Sampling depth:</th>
<td>programmable</td>
</tr>
<tr>
<th>Filling speed:</th>
<td>programmable</td>
</tr>
<tr>
<th>Viscosity delay:</th>
<td>0-25s</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection mode:</th>
<td>Full Loop</td>
</tr>
<tr>
<th>Supported loops</th>
<td>20; 50; 100ml</td>
</tr>
<tr>
<th>Cycle time:</th>
<td>≤ 60sec</td>
</tr>
<tr>
<th>Analysis time:</th>
<td>0-999min</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Physical features</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Dimensions (WxHxD)2:</th>
<td>355x380x520mm</td>
</tr>
<tr>
<th>Weight:</th>
<td>8kg</td>
</tr>
<tr>
<th>Power supply:</th>
<td>100-240±10%Vac; 50-60Hz; 60W</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/no-frills-hplc-autosampler/">No Frills HPLC AUTOSAMPLER</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>The HPLC autosampler lab-automation ready</title>
		<link>https://www.iconsci.com/shop/the-hplc-autosampler-ht4000l/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Fri, 12 Apr 2019 09:59:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/the-hplc-autosampler-ht4000l/</guid>

					<description><![CDATA[<p>Free software “HTA Autosampler Manager (Standard Version)“ is provided for PC control; upgrade to “HTA Autosampler Manager (CFR 21 Part 11 Version)“ should be purchased separately. PC is required for setup, service, method and sequence editing.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/the-hplc-autosampler-ht4000l/">The HPLC autosampler lab-automation ready</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>When it comes to designing and manufacturing robotics solutions, there’s no company more dedicated, experienced and knowledgeable in the scientific industry than HTA. We offer an extensive collection of analyzer front-ends and sample preparation workstations designed to fit applications in analytical chemistry, life sciences and clinical laboratories; this even includes GC, LC and ICP autosamplers. HTA manufactures in Italy under a certified UNI EN ISO 9001:2015 and 13485:2016 quality management systems.</p>
<h2 class="h1">Key Features</h2>
<h2 class="table-module__header">EASY TO USE</h2>
<p>Easy to use, easy to install and easy to service. We believe in a “robust by design” approach: HT4000L – based on cutting edge technologies and DFX design – well incarnates this philosophy making itself the ideal instrument for installation in any scenario.<br />
Full loop is performed with very high accuracy values, while partial loop also allows sample saving. The variable fill<br />
speed and the viscosity delay allow a wide range of sample viscosities; programmable sampling depth assures high sample recovery capacity. All the routine operations such as analysis start, sample loading and extra wash can be managed by its dedicated keypad. Set your method once using the complimentary HTA Autosampler Manager, then you just need to load samples and press START: experience a seamless integration with your Chromatography Data System.</p>
<h2 class="table-module__header">LARGE SAMPLE CAPACITY</h2>
<p>HT4000L can handle up to 176 2ml-vials per run or it can work with different kinds of sample vessels. Inject samples out of vials (2/4/6/10/20/40 ml), test tubes, tube blocks or plates.<br />
Save on consumables avoiding needs for sample reformatting. Choose from standard racks or enquire for a custom design: custom racks pay for themselves in a few weeks. Furthermore, racks are easily interchangeable in order to allow quick switching across multiple configurations.No compromise in terms of solvent capacity and solvent selection: we have a wide capacity to accommodate the most challenging requests. Solvents can be located in vials (for accurate micro- or nano-volume dispensing) or in bottles (for large-volume dispensing). Additional solvents modules may also be implemented in the field in case requirements change over the time.No need for solvent degassing. While some autosamplers require a devoted degasser line or to degas offline wash solvent on each bottle refill, we do not. Enjoy HT4000L: less system requirement, less pain, less troubleshooting!</p>
<h2 class="table-module__header">APPLICATION VERSATILITY</h2>
<p>HT4000L fits all liquid chromatography systems. It is able to look after the widest range of applications including analytical, prep, UHPLC, IC, nano, LC/ MS… and many more.</p>
<p>Within the standard configuration the autosampler is equipped with an automatic 6-port 2-way injection valve for analytical applications. However, a wide selection of valves for inert or extended pressure applications are also available as per special injection ports for applications where no valve is needed.</p>
<h2 class="table-module__header">MODULAR AND SCALABLE</h2>
<p>A wide range of accessories can be sourced and added in the field at any time. Contact your sales representative about your application requirement. Too many options? Don’t worry; you don’t pay for features you don’t need. We provide your LC autosampler at the best possible price; at the time your needs change you can add optional accessories to perform the new tasks without the hassle of buying a new autosampler. Your investment is future proof!</p>
<h2 class="table-module__header">LAB AUTOMATION READY</h2>
<p>HT4000L can fully automate your sample prep. It can work as a standard HPLC autosampler. However you may want to delegate some sample preparation tasks: HT4000L can take care of them as no standard autosampler has been able to assist.</p>
<p>Dilution, precolumn derivatisation, pH spiking and internal standard addition are available within the standard<br />
version: no extra cost required. These operations can be performed in place or in an empty vial by sample dispatching.</p>
<p>If standard sample preparation capabilities are not enough, get the HTAPREP option. Using HTAPREP &#8211; lab automation software &#8211; you can add support to complex and custom autosampler methods. Design your own methods by Drag&amp;Drop of autosampler functions (e.g. draw, dispense, mix, inject&#8230;) and start processing samples with the smart processing engine that allows you to optimise productivity and reagent consumption.</p>
<p>Endless possibilities: any sample preparation procedure or complex sample introduction become available: check the brochure of HT4000A (off-line version of HT4000L) to discover more.</p>
<h2 class="table-module__header">UHPLC READY</h2>
<p>UHPLC applications require an extended pressure range and a reduced amount of injected sample. HT4000L is optimised for such requirements and can be supplied with an UHPLC injection valve or can be upgraded in the field at a later time.Also in this configuration HT4000L features extraordinary analytical performance with the highest reliability.</p>
<h2 class="table-module__header">LARGE-VOLUME CAPABILITY</h2>
<p>The only real autosampler choice in the market for large-volume applications.We provide you with everything you need for your large-volume applications: large sample vessel support, large injections up to 10ml, large solvent capacity, large bore size injection valve (or injection port) for real and complete automation.</p>
<h2 class="table-module__header">BIOCOMPATIBLE</h2>
<p>To handle more complex samples and to assure covering a wider pH range, inert flow path valves are available. No need to compromise when it comes to running metal-sensitive samples or corrosive solvents/buffers.</p>
<p>Furthermore, biocompatible applications can take advantage of the double wash step capability: as pre- and post-wash solvent in addition to A, B… F solvents you can also choose a combination of A+B, A+C…. F+E solvents for superior analytical performance (carryover adverse!).</p>
<h2 class="table-module__header">COOLING</h2>
<p>The Cooling Module offers the capability to maintain samples at a controlled temperature. The cooling option upgrade can be performed in the field in a very short time: you don’t need to make a decision about cooling at the time the autosampler is sourced!</p>
<h1 class="headline">Technical Specifications</h1>
<div class="ginfo">
<h2 class="table-module__header">General features</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Syringe volume:</th>
<td>Standard: 100, 250, 500ml and 1, 2.5, 10mlNano-Volume Opt.: 5, 10, 25, 100m</td>
</tr>
<tr>
<th>Tray capacity (standard):</th>
<td>176 vials, 2ml (1 removable rack), 96 vials, 4ml (1 removable rack)54 vials, 6/10/20ml (1 removable rack)3, 96-well plates (1 removable rack)Custom trays available</td>
</tr>
<tr>
<th>Tray capacity (cooled):</th>
<td>121 vials, 2ml42 vials, 6/10/20ml2 96-well plates</td>
</tr>
<tr>
<th>Maintenance:</th>
<td>Preventive counters available</td>
</tr>
<tr>
<th>Electrical control:</th>
<td>LAN and TTL</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>RSD:</th>
<td>Full loop: ≤ 0.25% (typically 0.15%),<br />
Partial loop: ≤ 0.5%</td>
</tr>
<tr>
<th>Linearity (r):</th>
<td>≥ 0.9999</td>
</tr>
<tr>
<th>Carry over2:</th>
<td>≤ 0.05% (with standard wash),typically ≤ 0.01% (with int/ext needle wash)</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Wash (Pre &amp; Post Injection)</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Washing cycle:</th>
<td>up to 15 (Mode: every injection/sample/step)</td>
</tr>
<tr>
<th>Reagents:</th>
<td>up to 2 different reagents for wash function</td>
</tr>
<tr>
<th>Stator wash:</th>
<td>programmable</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Filling</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Sample volume:</th>
<td>as low as step of 1ml3</td>
</tr>
<tr>
<th>Air volume:</th>
<td>as low as step of 1ml3</td>
</tr>
<tr>
<th>Filling speed:</th>
<td>1-100ml /sec3</td>
</tr>
<tr>
<th>Viscosity delay:</th>
<td>0-25s</td>
</tr>
<tr>
<th>Bubble elimination:</th>
<td>up to 15 pull up strokes</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">Injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection mode:</th>
<td>Full Loop, Partial Loop</td>
</tr>
<tr>
<th>Flush Volume:</th>
<td>programmable</td>
</tr>
<tr>
<th>Injection speed:</th>
<td>1-500ml /sec3</td>
</tr>
<tr>
<th>Analysis time:</th>
<td>0-999min</td>
</tr>
<tr>
<th>Wait time between consecutive injections:</th>
<td>as low as 12sec4</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">Diluition, derivatization, pH spiking, IS addiction</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Reagent addiction:</th>
<td>step of 1ml3; up to 3 different reagents</td>
</tr>
<tr>
<th>Mixing cycle:</th>
<td>programmable</td>
</tr>
<tr>
<th>Intermediate wash cycle:</th>
<td>up to 15</td>
</tr>
<tr>
<th>Reaction time:</th>
<td>0-100 minutes (0.1 minutes step)</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">Physical features</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Dimensions (WxHxD):</th>
<td>310x705x690mm</td>
</tr>
<tr>
<th>Weight:</th>
<td>15kg</td>
</tr>
<tr>
<th>Power supply:</th>
<td>100-240±10%Vac; 50-60Hz; 55W</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">Cooling Module</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Technology:</th>
<td>Peltier</td>
</tr>
<tr>
<th>Temperature range conditioning:</th>
<td>from 4°C to 40°C</td>
</tr>
<tr>
<th>Temperature accuracy:</th>
<td>+/-1°C (typically +/-0.5°C) between the vials</td>
</tr>
<tr>
<th>Cooling capacity:</th>
<td>about 20°C below the RT (on the vial)</td>
</tr>
<tr>
<th>Working ambient temperature:</th>
<td>25°C +/-10°C</td>
</tr>
<tr>
<th>Weight:</th>
<td>about 5kg</td>
</tr>
<tr>
<th>Power supply:</th>
<td>100-240±10%Vac; 50-60Hz; 120W</td>
</tr>
<tr>
<th>Field installation:</th>
<td>yes</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">Additional modules:</h2>
<p>Among the most popular modules:</p>
<ul>
<li>Barcode reader (BCR)</li>
<li>Flow Cell</li>
<li>Gripper for vial displacement</li>
<li>Internal/external needle washing</li>
<li>Sample Capacity Extension</li>
<li>Vial Heater/ Reaction Cell</li>
<li>Vortex</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/the-hplc-autosampler-ht4000l/">The HPLC autosampler lab-automation ready</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Autosampler AS 6.1L</title>
		<link>https://www.iconsci.com/shop/autosampleras61l-aaa41aa/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Fri, 02 Mar 2018 15:43:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/autosampleras61l-aaa41aa/</guid>

					<description><![CDATA[<p>preparative HPLC autosampler with sample cooling</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa41aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>preparative version with sample cooling/heating</p>
<p>The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported. Preparative version for sample volumes up to 10 ml with sample tray cooling (4 &#8211; 40°C).</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Sample injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Autosampler Flow Path</th>
<td>Preparative</td>
</tr>
<tr>
<th>Maximum back pressure</th>
<td>200 bar</td>
</tr>
<tr>
<th>Vial/plate dimensions</th>
<td>max. plate/vial height: 47 mm (incl. septa or capmat)</td>
</tr>
<tr>
<th>Injection volume range</th>
<td>0.1 µl &#8211; 10 ml depending on sample loop</td>
</tr>
<tr>
<th>Sample loop</th>
<td>10 ml</td>
</tr>
<tr>
<th>Dispenser syringe</th>
<td>2500 µl</td>
</tr>
<tr>
<th>Headspace pressure</th>
<td>built-in compressor, only for sample vials with septum</td>
</tr>
<tr>
<th>Switching time inj. valve</th>
<td>&lt; 100 ms</td>
</tr>
<tr>
<th>Piercing needle precision</th>
<td>± 0.6 mm</td>
</tr>
<tr>
<th>Sample tray cooling</th>
<td>4 &#8211; 20 °C</td>
</tr>
<tr>
<th>Vial detection</th>
<td>missing vial/well plate detection by sensor</td>
</tr>
<tr>
<th>Needle wash</th>
<td>programmable: wash between injections and wash between vials</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>stainless steel (SS316), Tefzel®, Vespel®, glass, Teflon® (PTFE), PEEK.</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection modes</th>
<td>partial loop filling</td>
</tr>
<tr>
<th>Injection precision</th>
<td>RSD (Relative Standard Deviation): full loop injection: &lt;0.3% partial loop injection at injection volume&gt;5 µl: &lt;0.5% microliter pickup injection at an injection volume&gt;5 µl: &lt;1.0%</td>
</tr>
<tr>
<th>Sample carryover</th>
<td>&lt; 0.1 % with standard needle wash RSD ≤ 1.0 % for partial loop filling, injection volumes&gt; 10 µl up to 50 % of the installed sample loop</td>
</tr>
<tr>
<th>Injections per vial</th>
<td>max. 9 injections</td>
</tr>
<tr>
<th>Injection cycle time</th>
<td>minimum 7 s from the same vial, 14 s from different vials; &lt; 60 s for&gt;100 µl sample injection in all injection modes, incl. 300 µl needle wash</td>
</tr>
<tr>
<th>Analysis time</th>
<td>max. 9 h, 59 min, 59 s</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>2 programmable TTL inputs (next injection, freeze, stop)</td>
</tr>
<tr>
<th>Outputs</th>
<td>1 programmable relay output (inject marker, auxiliary, alarm)</td>
</tr>
<tr>
<th>Control</th>
<td>Ethernet (LAN)</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN, analog</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F air humidity: 20 &#8211; 80%</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>90–240 V AC</td>
</tr>
<tr>
<th>Dimensions</th>
<td>377 x 300 x 575 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>32 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.7 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L Benutzerhandbuch DE (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa41aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Autosampler AS 6.1L</title>
		<link>https://www.iconsci.com/shop/autosampleras61l-4/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Fri, 02 Mar 2018 15:08:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/autosampleras61l-4/</guid>

					<description><![CDATA[<p>preparative HPLC autosampler</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-4/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>preparative version</p>
<p>The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported. Preparative version for sample volumes up to 10 ml.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Sample injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Autosampler Flow Path</th>
<td>Preparative</td>
</tr>
<tr>
<th>Maximum back pressure</th>
<td>200 bar</td>
</tr>
<tr>
<th>Vial/plate dimensions</th>
<td>max. plate/vial height: 47 mm (incl. septa or capmat)</td>
</tr>
<tr>
<th>Injection volume range</th>
<td>0.1 µl &#8211; 10 ml depending on sample loop</td>
</tr>
<tr>
<th>Sample loop</th>
<td>10 ml</td>
</tr>
<tr>
<th>Dispenser syringe</th>
<td>2500 µl</td>
</tr>
<tr>
<th>Headspace pressure</th>
<td>built-in compressor, only for sample vials with septum</td>
</tr>
<tr>
<th>Switching time inj. valve</th>
<td>&lt; 100 ms</td>
</tr>
<tr>
<th>Piercing needle precision</th>
<td>± 0.6 mm</td>
</tr>
<tr>
<th>Sample tray cooling</th>
<td>none</td>
</tr>
<tr>
<th>Vial detection</th>
<td>missing vial/well plate detection by sensor</td>
</tr>
<tr>
<th>Needle wash</th>
<td>programmable: wash between injections and wash between vials</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Tefzel® (ETFE), Glass, Teflon® (PTFE), Kel-F® (PCTFE), stainless steel, PEEK</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection modes</th>
<td>partial loop filling</td>
</tr>
<tr>
<th>Injection precision</th>
<td>RSD (Relative Standard Deviation):full loop injection: &lt;0.3%partial loop injection at injection volume&gt;5 µl: &lt;0.5%microliter pickup injection at an injection volume&gt;5 µl: &lt;1.0%</td>
</tr>
<tr>
<th>Sample carryover</th>
<td>&lt; 0.1 % with standard needle washRSD ≤ 1.0 % for partial loop filling, injection volumes&gt; 10 µl up to 50 % of the installed sample loop</td>
</tr>
<tr>
<th>Injections per vial</th>
<td>max. 9 injections</td>
</tr>
<tr>
<th>Injection cycle time</th>
<td>minimum 7 s from the same vial, 14 s from different vials;&lt; 60 s for&gt;100 µl sample injection in all injection modes, incl. 300 µl needle wash</td>
</tr>
<tr>
<th>Analysis time</th>
<td>max. 9 h, 59 min, 59 s</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>2 programmable TTL inputs (next injection, freeze, stop)</td>
</tr>
<tr>
<th>Outputs</th>
<td>1 programmable relay output (inject marker, auxiliary, alarm)</td>
</tr>
<tr>
<th>Control</th>
<td>Ethernet (LAN)</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN, analog</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F air humidity: 20 &#8211; 80%</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>95–240 V AC</td>
</tr>
<tr>
<th>Dimensions</th>
<td>377 x 300 x 510 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>30 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.7 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L Benutzerhandbuch DE (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-4/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Autosampler AS 6.1L</title>
		<link>https://www.iconsci.com/shop/autosampleras61l-aaa31aa/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Fri, 02 Mar 2018 15:05:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/autosampleras61l-aaa31aa/</guid>

					<description><![CDATA[<p>preparative HPLC autosampler with biocompatible flow path and cooling option</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa31aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>biocompatible, preparative version with sample cooling/heating</p>
<p>The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. “partial loop filling” (variable volumes, e.g. for dilution series) is supported. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported. Preparative version for sample volumes up to 10 ml with biocompatible flow path.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Sample injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Autosampler Flow Path</th>
<td>Biocompatible-preparative</td>
</tr>
<tr>
<th>Maximum back pressure</th>
<td>200 bar</td>
</tr>
<tr>
<th>Vial/plate dimensions</th>
<td>max. plate/vial height: 47 mm (incl. septa or capmat)</td>
</tr>
<tr>
<th>Injection volume range</th>
<td>0.1 µl &#8211; 10 ml depending on sample loop</td>
</tr>
<tr>
<th>Sample loop</th>
<td>10 ml</td>
</tr>
<tr>
<th>Dispenser syringe</th>
<td>2500 µl</td>
</tr>
<tr>
<th>Headspace pressure</th>
<td>built-in compressor, only for vials with septum</td>
</tr>
<tr>
<th>Switching time inj. valve</th>
<td>&lt; 100 ms</td>
</tr>
<tr>
<th>Piercing needle precision</th>
<td>± 0.6 mm</td>
</tr>
<tr>
<th>Sample tray cooling</th>
<td>4 &#8211; 20 °C</td>
</tr>
<tr>
<th>Vial detection</th>
<td>missing vial/well plate detection by sensor</td>
</tr>
<tr>
<th>Needle wash</th>
<td>programmable: wash between injections and wash between vials</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>Tefzel® (ETFE), Glass, Teflon® (PTFE), Kel-F® (PCTFE), PEEK</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection modes</th>
<td>partial loop filling</td>
</tr>
<tr>
<th>Injection precision</th>
<td>RSD (Relative Standard Deviation):full loop filling: &lt;0.3%partial loop fillings at injection volumes&gt;5 µl: &lt;0.5%microliter pickup at injections&gt;5 µl: &lt;1.0%</td>
</tr>
<tr>
<th>Sample carryover</th>
<td>10 µl up to 50 % of the installed sample loop</td>
</tr>
<tr>
<th>Injections per vial</th>
<td>max. 9 injections</td>
</tr>
<tr>
<th>Injection cycle time</th>
<td>minimum 7 s from the same vial, 14 s from different vials;&lt; 60 s for&gt;100 µl sample injection in all injection modes, incl. 300 µl needle wash</td>
</tr>
<tr>
<th>Analysis time</th>
<td>max. 9 h, 59 min, 59 s</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>2 programmable TTL inputs (next injection, freeze, stop)</td>
</tr>
<tr>
<th>Outputs</th>
<td>1 programmable relay output (inject marker, auxiliary, alarm)</td>
</tr>
<tr>
<th>Control</th>
<td>Ethernet (LAN)</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN, analog</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F air humidity: 20 &#8211; 80%</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>95–240 V AC</td>
</tr>
<tr>
<th>Dimensions</th>
<td>377 x 300 x 575 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>32 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.7 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L Benutzerhandbuch DE (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa31aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Autosampler AS 6.1L</title>
		<link>https://www.iconsci.com/shop/autosampleras61l-aaa21aa/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Fri, 02 Mar 2018 14:47:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/autosampleras61l-aaa21aa/</guid>

					<description><![CDATA[<p>analytical HPLC autosampler with biocompatible flow path and sample cooling</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa21aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>biocompatible version with sample cooling/heating</p>
<p>The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported. With sample tray cooling (4 &#8211; 22°C) and biocompatible sample path.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Sample injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Autosampler Flow Path</th>
<td>Biocompatible</td>
</tr>
<tr>
<th>Maximum back pressure</th>
<td>345 bar</td>
</tr>
<tr>
<th>Vial/plate dimensions</th>
<td>max. plate/vial height: 47 mm (incl. septa or capmat)</td>
</tr>
<tr>
<th>Injection volume range</th>
<td>0.1 µl &#8211; 10 ml depending on sample loop</td>
</tr>
<tr>
<th>Sample loop</th>
<td>100 µl</td>
</tr>
<tr>
<th>Dispenser syringe</th>
<td>250 µl</td>
</tr>
<tr>
<th>Headspace pressure</th>
<td>built-in compressor, only for sample vials with septum</td>
</tr>
<tr>
<th>Switching time inj. valve</th>
<td>&lt; 100 ms</td>
</tr>
<tr>
<th>Piercing needle precision</th>
<td>± 0.6 mm</td>
</tr>
<tr>
<th>Sample tray cooling</th>
<td>4 &#8211; 20 °C</td>
</tr>
<tr>
<th>Vial detection</th>
<td>missing vial/well plate detection by sensor</td>
</tr>
<tr>
<th>Needle wash</th>
<td>programmable: wash between injections and wash between vials</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>
<p>Tefzel® (ETFE), Glass, Teflon® (PTFE), Kel-F® (PCTFE), PEEK</p>
</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection modes</th>
<td>full loop filling, partial loop filling and microliter pickup; PASA™ (pressure-assisted sample aspiration)</td>
</tr>
<tr>
<th>Injection precision</th>
<td>RSD (Relative Standard Deviation):full loop filling: &lt;0.3%partial loop fillings at injection volumes&gt;5 µl: &lt;0.5%microliter pickup at injections&gt;5 µl: &lt;1.0%</td>
</tr>
<tr>
<th>Sample carryover</th>
<td>&lt; 0.05 % with needle washing</td>
</tr>
<tr>
<th>Injections per vial</th>
<td>max. 9 injections</td>
</tr>
<tr>
<th>Injection cycle time</th>
<td>minimum 7 s from the same vial, 14 s from different vials;&lt; 60 s for&gt;100 µl sample injection in all injection modes, incl. 300 µl needle wash</td>
</tr>
<tr>
<th>Analysis time</th>
<td>max. 9 h, 59 min, 59 s</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>2 programmable TTL inputs (next injection, freeze, stop)</td>
</tr>
<tr>
<th>Outputs</th>
<td>1 programmable relay output (inject marker, auxiliary, alarm)</td>
</tr>
<tr>
<th>Control</th>
<td>Ethernet (LAN)</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN, analog</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F air humidity: 20 &#8211; 80%</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>95–240 V AC</td>
</tr>
<tr>
<th>Dimensions</th>
<td>377 x 300 x 575 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>32 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.7 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L Benutzerhandbuch DE (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa21aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Autosampler AS 6.1L</title>
		<link>https://www.iconsci.com/shop/autosampleras61l-aaa20aa/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Fri, 02 Mar 2018 14:41:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/autosampleras61l-aaa20aa/</guid>

					<description><![CDATA[<p>analytical HPLC autosampler with biocompatible flow path</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa20aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>biocompatible version</p>
<p>The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported. With biocompatible sample path.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Sample injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Autosampler Flow Path</th>
<td>Biocompatible</td>
</tr>
<tr>
<th>Maximum back pressure</th>
<td>345 bar</td>
</tr>
<tr>
<th>Vial/plate dimensions</th>
<td>max. plate/vial height: 47 mm (incl. septa or capmat)</td>
</tr>
<tr>
<th>Injection volume range</th>
<td>0.1 µl &#8211; 10 ml depending on sample loop</td>
</tr>
<tr>
<th>Sample loop</th>
<td>100 µl</td>
</tr>
<tr>
<th>Dispenser syringe</th>
<td>250 µl</td>
</tr>
<tr>
<th>Headspace pressure</th>
<td>built-in compressor, only for sample vials with septum</td>
</tr>
<tr>
<th>Switching time inj. valve</th>
<td>&lt; 100 ms</td>
</tr>
<tr>
<th>Piercing needle precision</th>
<td>± 0.6 mm</td>
</tr>
<tr>
<th>Sample tray cooling</th>
<td>none</td>
</tr>
<tr>
<th>Vial detection</th>
<td>missing vial/well plate detection by sensor</td>
</tr>
<tr>
<th>Needle wash</th>
<td>programmable: wash between injections and wash between vials</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>
<p>Tefzel® (ETFE), Glass, Teflon® (PTFE), Kel-F® (PCTFE), PEEK</p>
</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection modes</th>
<td>full loop filling, partial loop filling and microliter pickup; PASA™ (pressure-assisted sample aspiration)</td>
</tr>
<tr>
<th>Injection precision</th>
<td>RSD (Relative Standard Deviation):full loop filling: &lt;0.3%partial loop fillings at injection volumes&gt;5 µl: &lt;0.5%microliter pickup at injections&gt;5 µl: &lt;1.0%</td>
</tr>
<tr>
<th>Sample carryover</th>
<td>&nbsp;</td>
</tr>
<tr>
<th>Injections per vial</th>
<td>max. 9 injections</td>
</tr>
<tr>
<th>Injection cycle time</th>
<td>minimum 7 s from the same vial, 14 s from different vials;100 µl sample injection in all injection modes, incl. 300 µl needle wash</td>
</tr>
<tr>
<th>Analysis time</th>
<td>max. 9 h, 59 min, 59 s</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>2 programmable TTL inputs (next injection, freeze, stop)</td>
</tr>
<tr>
<th>Outputs</th>
<td>1 programmable relay output (inject marker, auxiliary, alarm)</td>
</tr>
<tr>
<th>Control</th>
<td>Ethernet (LAN)</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN, analog</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F air humidity: 20 &#8211; 80%</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>95–240 V AC</td>
</tr>
<tr>
<th>Dimensions</th>
<td>377 x 300 x 575 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>32 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.7 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L Benutzerhandbuch DE (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa20aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Autosampler AS 6.1L</title>
		<link>https://www.iconsci.com/shop/autosampleras61l-aaa11aa/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 01 Mar 2018 19:06:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/autosampleras61l-aaa11aa/</guid>

					<description><![CDATA[<p>cooling/heating version of a fast and very versatile analytical HPLC autosampler, 1240 bar, 0.1-10000 µl injection volume</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa11aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>cooling/heating version, 1240 bar</p>
<p>The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported. For high-pressure injections of up to 1240 bar, the autosampler is equipped with a so-called ILD™ valve (Intermediate Loop Decompression). This valve consists of a rotor-stator combination and includes a central port for depressurizing. For highpressure applications, the sample loop is depressurized prior to receiving the sample. This way, the sample is not diluted with solvent. Because the valve is switched extremely fast, pressure spikes are reduced. Analyses are more precise and wear of the column is reduced.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Sample injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Autosampler Flow Path</th>
<td>Analytical</td>
</tr>
<tr>
<th>Maximum back pressure</th>
<td>1240 bar</td>
</tr>
<tr>
<th>Vial/plate dimensions</th>
<td>max. plate/vial height: 47 mm (incl. septa or capmat)</td>
</tr>
<tr>
<th>Injection volume range</th>
<td>0.1 µl &#8211; 10 ml depending on sample loop</td>
</tr>
<tr>
<th>Sample loop</th>
<td>10 µl</td>
</tr>
<tr>
<th>Dispenser syringe</th>
<td>250 µl</td>
</tr>
<tr>
<th>Headspace pressure</th>
<td>built-in compressor, only for sample vials with septum</td>
</tr>
<tr>
<th>Switching time inj. valve</th>
<td>&lt; 100 ms</td>
</tr>
<tr>
<th>Piercing needle precision</th>
<td>± 0.6 mm</td>
</tr>
<tr>
<th>Sample tray cooling</th>
<td>4 &#8211; 40 °C</td>
</tr>
<tr>
<th>Vial detection</th>
<td>missing vial/well plate detection by sensor</td>
</tr>
<tr>
<th>Needle wash</th>
<td>programmable: wash between injections and wash between vials</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>
<p>Tefzel® (ETFE), Glass, Teflon® (PTFE), Kel-F® (PCTFE), stainless steel, PEEK</p>
</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection modes</th>
<td>full loop filling, partial loop filling and microliter pickup; PASA™ (pressure-assisted sample aspiration)</td>
</tr>
<tr>
<th>Injection precision</th>
<td>RSD (Relative Standard Deviation):full loop filling: &lt;0.3%partial loop fillings at injection volumes&gt;5 µl: &lt;0.5%microliter pickup at injections&gt;5 µl: &lt;1.0%</td>
</tr>
<tr>
<th>Sample carryover</th>
<td>&lt; 0.05 % with needle washing</td>
</tr>
<tr>
<th>Injections per vial</th>
<td>max. 9 injections</td>
</tr>
<tr>
<th>Injection cycle time</th>
<td>minimum 7 s from the same vial, 14 s from different vials;&lt; 60 s for&gt;100 µl sample injection in all injection modes, incl. 300 µl needle wash</td>
</tr>
<tr>
<th>Analysis time</th>
<td>max. 9 h, 59 min, 59 s</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>2 programmable TTL inputs (next injection, freeze, stop)</td>
</tr>
<tr>
<th>Outputs</th>
<td>1 programmable relay output (inject marker, auxiliary, alarm)</td>
</tr>
<tr>
<th>Control</th>
<td>Ethernet (LAN)</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN, analog</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F air humidity: 20 &#8211; 80%</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>95–240 V AC</td>
</tr>
<tr>
<th>Dimensions</th>
<td>377 x 300 x 575 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>32 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.7 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa11aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Autosampler AS 6.1L</title>
		<link>https://www.iconsci.com/shop/autosampleras61l-aaa01aa/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 01 Mar 2018 18:58:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/autosampleras61l-aaa01aa/</guid>

					<description><![CDATA[<p>cooling/heating version of a fast and very versatile analytical HPLC autosampler, 700 bar, 0.1-10000 µl injection volume</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa01aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>cooling/heating version, 700 bar</p>
<p>The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported. For high-pressure injections of up to 700 bar, the autosampler is equipped with a so-called ILD™ valve (Intermediate Loop Decompression). This valve consists of a rotor-stator combination and includes a central port for depressurizing. For high pressure applications, the sample loop is depressurized prior to receiving the sample. This way, the sample is not diluted with solvent. Because the valve is switched extremely fast, pressure spikes are reduced. Analyses are more precise and wear of the column is reduced.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Sample injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Autosampler Flow Path</th>
<td>Analytical</td>
</tr>
<tr>
<th>Maximum back pressure</th>
<td>700 bar</td>
</tr>
<tr>
<th>Vial/plate dimensions</th>
<td>max. plate/vial height: 47 mm (incl. septa or capmat)</td>
</tr>
<tr>
<th>Injection volume range</th>
<td>0.1 µl &#8211; 10 ml depending on sample loop</td>
</tr>
<tr>
<th>Sample loop</th>
<td>100 µl</td>
</tr>
<tr>
<th>Dispenser syringe</th>
<td>250 µl</td>
</tr>
<tr>
<th>Headspace pressure</th>
<td>built-in compressor, only for sample vials with septum</td>
</tr>
<tr>
<th>Switching time inj. valve</th>
<td>&lt; 100 ms</td>
</tr>
<tr>
<th>Piercing needle precision</th>
<td>± 0.6 mm</td>
</tr>
<tr>
<th>Sample tray cooling</th>
<td>4 &#8211; 40 °C</td>
</tr>
<tr>
<th>Vial detection</th>
<td>missing vial/well plate detection by sensor</td>
</tr>
<tr>
<th>Needle wash</th>
<td>programmable: wash between injections and wash between vials</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>
<p>Tefzel® (ETFE), Glass, Teflon® (PTFE), Kel-F® (PCTFE), stainless steel, PEEK</p>
</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection modes</th>
<td>full loop filling, partial loop filling and microliter pickup; PASA™ (pressure-assisted sample aspiration)</td>
</tr>
<tr>
<th>Injection precision</th>
<td>RSD (Relative Standard Deviation):full loop filling: &lt;0.3%partial loop fillings at injection volumes&gt;5 µl: &lt;0.5%microliter pickup at injections&gt;5 µl: &lt;1.0%</td>
</tr>
<tr>
<th>Sample carryover</th>
<td>&lt; 0.05 % with programmable needle wash</td>
</tr>
<tr>
<th>Injections per vial</th>
<td>max. 9 injections</td>
</tr>
<tr>
<th>Injection cycle time</th>
<td>minimum 7 s from the same vial, 14 s from different vials;&lt; 60 s for&gt;100 µl sample injection in all injection modes, incl. 300 µl needle wash</td>
</tr>
<tr>
<th>Analysis time</th>
<td>max. 9 h, 59 min, 59 s</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>2 programmable TTL inputs (next injection, freeze, stop)</td>
</tr>
<tr>
<th>Outputs</th>
<td>1 programmable relay output (inject marker, auxiliary, alarm)</td>
</tr>
<tr>
<th>Control</th>
<td>Ethernet (LAN)</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN, analog</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F air humidity: 20 &#8211; 80%</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>95–240 V AC</td>
</tr>
<tr>
<th>Dimensions</th>
<td>377 x 300 x 575 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>32 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.7 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa01aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Autosampler AS 6.1L</title>
		<link>https://www.iconsci.com/shop/autosampleras61l-aaa10aa/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 01 Mar 2018 18:54:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/autosampleras61l-aaa10aa/</guid>

					<description><![CDATA[<p>standard version of a fast and very versatile analytical HPLC autosampler, 1240 bar, 0.1-10000 µl injection volume</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa10aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>standard version, 1240 bar</p>
<p>The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported. For high-pressure injections of up to 1240 bar, the autosampler is equipped with a so-called ILD™ valve (Intermediate Loop Decompression). This valve consists of a rotor-stator combination and includes a central port for depressurizing. For highpressure applications, the sample loop is depressurized prior to receiving the sample. This way, the sample is not diluted with solvent. Because the valve is switched extremely fast, pressure spikes are reduced. Analyses are more precise and wear of the column is reduced.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Sample injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Autosampler Flow Path</th>
<td>Analytical</td>
</tr>
<tr>
<th>Maximum back pressure</th>
<td>1240 bar</td>
</tr>
<tr>
<th>Vial/plate dimensions</th>
<td>max. plate/vial height: 47 mm (incl. septa or capmat)</td>
</tr>
<tr>
<th>Injection volume range</th>
<td>0.1 µl &#8211; 10 ml depending on sample loop</td>
</tr>
<tr>
<th>Sample loop</th>
<td>10 µl</td>
</tr>
<tr>
<th>Dispenser syringe</th>
<td>250 µl</td>
</tr>
<tr>
<th>Headspace pressure</th>
<td>built-in compressor, only for sample vials with septum</td>
</tr>
<tr>
<th>Switching time inj. valve</th>
<td>&lt; 100 ms</td>
</tr>
<tr>
<th>Piercing needle precision</th>
<td>± 0.6 mm</td>
</tr>
<tr>
<th>Sample tray cooling</th>
<td>none</td>
</tr>
<tr>
<th>Vial detection</th>
<td>missing vial/well plate detection by sensor</td>
</tr>
<tr>
<th>Needle wash</th>
<td>programmable: wash between injections and wash between vials</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>
<p>Tefzel® (ETFE), Glass, Teflon® (PTFE), Kel-F® (PCTFE), stainless steel, PEEK</p>
</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection modes</th>
<td>full loop filling, partial loop filling and microliter pickup; PASA™ (pressure-assisted sample aspiration)</td>
</tr>
<tr>
<th>Injection precision</th>
<td>RSD (Relative Standard Deviation):full loop filling: &lt;0.3%partial loop injection at injection volumes&gt;5 µl: &lt;0.5%microliter pickup at injections&gt;5 µl: &lt;1.0%</td>
</tr>
<tr>
<th>Sample carryover</th>
<td>&lt; 0.05 % with needle washing</td>
</tr>
<tr>
<th>Injections per vial</th>
<td>max. 9 injections</td>
</tr>
<tr>
<th>Injection cycle time</th>
<td>minimum 7 s from the same vial, 14 s from different vials;&lt; 60 s for&gt;100 µl sample injection in all injection modes, incl. 300 µl needle wash</td>
</tr>
<tr>
<th>Analysis time</th>
<td>max. 9 h, 59 min, 59 s</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>2 programmable TTL inputs (next injection, freeze, stop)</td>
</tr>
<tr>
<th>Outputs</th>
<td>1 programmable relay output (inject marker, auxiliary, alarm)</td>
</tr>
<tr>
<th>Control</th>
<td>Ethernet (LAN)</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN, analog</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F air humidity: 20 &#8211; 80%</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>95–240 V AC</td>
</tr>
<tr>
<th>Dimensions</th>
<td>377 x 300 x 510 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>30 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.7 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa10aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Autosampler AS 6.1L</title>
		<link>https://www.iconsci.com/shop/autosampleras61l-aaa00aa/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 01 Mar 2018 18:03:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/autosampleras61l-aaa00aa/</guid>

					<description><![CDATA[<p>standard version of a fast and very versatile analytical HPLC autosampler, 700 bar, 0.1-10000 µl injection volume</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa00aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>standard version, 700 bar</p>
<p>The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported. For high-pressure injections of up to 700 bar, the autosampler is equipped with a so-called ILD™ valve (Intermediate Loop Decompression). This valve consists of a rotor-stator combination and includes a central port for depressurizing. For high pressure applications, the sample loop is depressurized prior to receiving the sample. This way, the sample is not diluted with solvent. Because the valve is switched extremely fast, pressure spikes are reduced. Analyses are more precise and wear of the column is reduced.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Sample injection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Autosampler Flow Path</th>
<td>Analytical</td>
</tr>
<tr>
<th>Maximum back pressure</th>
<td>700 bar</td>
</tr>
<tr>
<th>Vial/plate dimensions</th>
<td>max. plate/vial height: 47 mm (incl. septa or capmat)</td>
</tr>
<tr>
<th>Injection volume range</th>
<td>0.1 µl &#8211; 10 ml depending on sample loop</td>
</tr>
<tr>
<th>Sample loop</th>
<td>100 µl</td>
</tr>
<tr>
<th>Dispenser syringe</th>
<td>250 µl</td>
</tr>
<tr>
<th>Headspace pressure</th>
<td>built-in compressore, only for sample vials with septum</td>
</tr>
<tr>
<th>Switching time inj. valve</th>
<td>&lt; 100 ms</td>
</tr>
<tr>
<th>Piercing needle precision</th>
<td>± 0.6 mm</td>
</tr>
<tr>
<th>Sample tray cooling</th>
<td>none</td>
</tr>
<tr>
<th>Vial detection</th>
<td>missing vial/well plate detection by sensor</td>
</tr>
<tr>
<th>Needle wash</th>
<td>programmable: wash between injections and wash between vials</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>
<p>Tefzel® (ETFE), Glass, Teflon® (PTFE), Kel-F® (PCTFE), stainless steel, PEEK</p>
</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Analytical performance</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Injection modes</th>
<td>full loop filling, partial loop filling and microliter pickup; PASA™ (pressure-assisted sample aspiration)</td>
</tr>
<tr>
<th>Injection precision</th>
<td>RSD (Relative Standard Deviation):full loop injection: &lt;0.3%partial loop injection at injection volume&gt;5 µl: &lt;0.5%microliter pickup injection at an injection volume&gt;5 µl: &lt;1.0%</td>
</tr>
<tr>
<th>Sample carryover</th>
<td>&lt; 0.05 % with needle washing</td>
</tr>
<tr>
<th>Injections per vial</th>
<td>max. 9 injections</td>
</tr>
<tr>
<th>Injection cycle time</th>
<td>minimum 7 s from the same vial, 14 s from different vials;&lt; 60 s for&gt;100 µl sample injection in all injection modes, incl. 300 µl needle wash</td>
</tr>
<tr>
<th>Analysis time</th>
<td>max. 9 h, 59 min, 59 s</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>2 programmable TTL inputs (next injection, freeze, stop)</td>
</tr>
<tr>
<th>Outputs</th>
<td>1 programmable relay output (inject marker, auxiliary, alarm)</td>
</tr>
<tr>
<th>Control</th>
<td>Ethernet (LAN)</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN, analog</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F air humidity: 20 &#8211; 80%</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>95–240 V AC</td>
</tr>
<tr>
<th>Dimensions</th>
<td>377 x 300 x 510 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>30 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.7 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_User-Manual_EN.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Autosampler AS 6.1L User Manual EN (V6821)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">2.8 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/V6821_Autosampler_AS_6.1L_Benutzerhandbuch_DE.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/autosampleras61l-aaa00aa/">Autosampler AS 6.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>