<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>VWD-1001F &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-tag/vwd-1001f/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Mon, 27 Apr 2026 13:24:17 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>VWD-1001F &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ANSER VWD-1001F</title>
		<link>https://www.iconsci.com/shop/anser-vwd-1001f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Thu, 20 Nov 2025 14:41:56 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4958</guid>

					<description><![CDATA[<p>ANSER VWD- 1001F Photometric Detectors UV-Detector with Deuterium lamp light source, variable wavelength (UV range 190-420 nm) Technical specifications Instrument [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1001f/">ANSER VWD-1001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER VWD- 1001F</strong><br />
<strong>Photometric Detectors</strong></p>
<p>UV-Detector with Deuterium lamp light source, variable wavelength (UV range 190-420 nm)</p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam spectrophotometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Deuterium lamps</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">UV/VIS, 190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 0.3 x 10-5 AU (dry analytical cell, 240 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10-4 AU (dry analytical cell, 240 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">100 Hz (1 wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">4“ LCD touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Start/Stop input<br />
Autozero input<br />
Error output<br />
Wavelength tuning analogue input, 0-10V<br />
2x Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<td width="128"><strong>Flow cells</strong></td>
<td width="269">10 mm path length, 2.5 μl volume (micro)<br />
10 mm path length, 8 μl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 μl volume (preparative)<br />
Other flow cells upon request<br />
Cell material: stainless steel, titanium, PEEK<br />
Fiber optic flow cell</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">127 x 178x 350 mm / 5.0 x 7.0 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">5 kg / 11 lbs.</td>
</tr>
<tr>
<td width="128"><strong>Data communication</strong></td>
<td width="269">LAN 10 / 100 Mbit/s USB 2.0 RS-232-C (115200 baud)</td>
</tr>