<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>fixed wavelength detector &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-tag/fixed-wavelength-detector/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Tue, 10 Mar 2026 13:25:54 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>fixed wavelength detector &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ANSER UVL1 Detector-3260</title>
		<link>https://www.iconsci.com/shop/anser-uvl1-detector-3260/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Tue, 10 Mar 2026 13:22:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4993</guid>

					<description><![CDATA[<p>Icon Scientific ANSER UV LED-3260 detector. The UV LED-3260 is a single fixed wavelength using a 260nm UV LED and [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-detector-3260/">ANSER UVL1 Detector-3260</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">Icon Scientific ANSER UV LED-3260 detector. The UV LED-3260 is a single fixed wavelength using a 260nm UV LED and a narrow band filter filter eliminating other bandwidths and reducing stray light. These detectors can handle a wide range of flow cells covering nano liters to liters/min. flow rates. Our full range of flow cells include fiber optic flow cells with fiber optics<br />
available in custom lengths. These detectors are also available in OEM modules.</p>
<h2>Specifications List</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Instrument type</th>
<td>Double-beam photometer with LED light source</td>
</tr>
<tr>
<th>Light source</th>
<td>260nm UV LED</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>280 nm</td>
</tr>
<tr>
<th>Number of wavelength channels</th>
<td>LED(s): 1 single fixed, 2 rapid switching</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.5 nm (LEDs)</td>
</tr>
<tr>
<th>Wavelength precision (reproducibility)</th>
<td>± 0.5 nm</td>
</tr>
<tr>
<th>Spectral resolution</th>
<td>&lt;12 nm (LEDs)</td>
</tr>
<tr>
<th>Noise</th>
<td>&lt;± 0.3 x 10-5 AU (dry analytical cell, 260 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<th>Drift</th>
<td>&lt;± 1 x 10-4 AU (dry analytical cell, 260 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Linearity range</th>
<td>&gt; 2.5 AU</td>
</tr>
<tr>
<th>Time constant</th>
<td>0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<th>Maximal output data rate</th>
<td>100 Hz</td>
</tr>
<tr>
<th>Communications</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<th>Stand-alone operation</th>
<td>TFT Touchpanel</td>
</tr>
<tr>
<th>Remote operation</th>
<td>Start/Stop input<br />
Autozero input<br />
Error output<br />
1 Absorption signal analogue output, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<th>Data communication</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C (115200 baud)</td>
</tr>
<tr>
<th>Flow cells</th>
<td>10 mm path length, 2.5 µl volume (micro)<br />
10 mm path length, 8 µl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 µl volume (preparative)<br />
Other Flow cell options Available<br />
Cell material: titanium, PEEK<br />
Fiber optics are available for remote sensing</td>
</tr>
<tr>
<th>Power</th>
<td>External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<th>Dimensions</th>
<td>95 x 155 x 300 mm / 4.0 x 6.25 x 12.0 in. (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>1.25 kg / 2.75 lbs</td>
</tr>
</tbody>
</table>
<h2>Order information:</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>LED light source, single wavelength</th>
<td>UVL1-3260</td>
</tr>
<tr>
<th></th>
<td></td>
</tr>
</tbody>
</table>
<p>Specifications are subject to change without notice</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-detector-3260/">ANSER UVL1 Detector-3260</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER UVL1 Detector</title>
		<link>https://www.iconsci.com/shop/anser-uvl1-detector/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Tue, 10 Mar 2026 13:01:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4992</guid>

					<description><![CDATA[<p>Icon Scientific ANSER UV LED-3280 detector. The UV LED-3280 is a single fixed wavelength using a 280nm UV LED and [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-detector/">ANSER UVL1 Detector</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">Icon Scientific ANSER UV LED-3280 detector. The UV LED-3280 is a single fixed wavelength using a 280nm UV LED and a narrow band filter filter eliminating other bandwidths and reducing stray light. These detectors can handle a wide range of flow cells covering nano liters to liters/min. flow rates. Our full range of flow cells include fiber optic flow cells with fiber optics<br />
available in custom lengths. These detectors are also available in OEM modules.</p>
<h2>Specifications List</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Instrument type</th>
<td>Double-beam photometer with LED light source</td>
</tr>
<tr>
<th>Light source</th>
<td>260nm UV LED</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>280 nm</td>
</tr>
<tr>
<th>Number of wavelength channels</th>
<td>LED(s): 1 single fixed, 2 rapid switching</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.5 nm (LEDs)</td>
</tr>
<tr>
<th>Wavelength precision (reproducibility)</th>
<td>± 0.5 nm</td>
</tr>
<tr>
<th>Spectral resolution</th>
<td>&lt;12 nm (LEDs)</td>
</tr>
<tr>
<th>Noise</th>
<td>&lt;± 0.3 x 10-5 AU (dry analytical cell, 280 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<th>Drift</th>
<td>&lt;± 1 x 10-4 AU (dry analytical cell, 280 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Linearity range</th>
<td>&gt; 2.5 AU</td>
</tr>
<tr>
<th>Time constant</th>
<td>0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<th>Maximal output data rate</th>
<td>100 Hz</td>
</tr>
<tr>
<th>Communications</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<th>Stand-alone operation</th>
<td>TFT Touchpanel</td>
</tr>
<tr>
<th>Remote operation</th>
<td>Start/Stop input<br />
Autozero input<br />
Error output<br />
1 Absorption signal analogue output, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<th>Data communication</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C (115200 baud)</td>
</tr>
<tr>
<th>Flow cells</th>
<td>10 mm path length, 2.5 µl volume (micro)<br />
10 mm path length, 8 µl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 µl volume (preparative)<br />
Other Flow cell options Available<br />
Cell material: titanium, PEEK<br />
Fiber optics are available for remote sensing</td>
</tr>
<tr>
<th>Power</th>
<td>External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<th>Dimensions</th>
<td>95 x 155 x 300 mm / 4.0 x 6.25 x 12.0 in. (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>1.25 kg / 2.75 lbs</td>
</tr>
</tbody>
</table>
<h2>Order information:</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>LED light source, single wavelength</th>
<td>UVL1-3280</td>
</tr>
<tr>
<th></th>
<td></td>
</tr>
</tbody>
</table>
<p>Specifications are subject to change without notice</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-detector/">ANSER UVL1 Detector</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER UVL1 / UVL2 LED Detectors</title>
		<link>https://www.iconsci.com/shop/anser-uvl1-uvl2-led-detectors-copy/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Tue, 10 Mar 2026 12:54:58 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4991</guid>

					<description><![CDATA[<p>Icon Scientific introduces ANSER LED detectors. Our LED detectors cover the UV from 240nm to 1050nm using either a single [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-uvl2-led-detectors-copy/">ANSER UVL1 / UVL2 LED Detectors</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">Icon Scientific introduces ANSER LED detectors. Our LED detectors cover the UV from<br />
240nm to 1050nm using either a single fixed LED or two LEDs using novel<br />
rapid switching technology. These detectors can handle a wide range of flow<br />
cells covering nano liters to liters/min. flow rates. Our full range of<br />
flow cells include fiber optic flow cells with fiber optics<br />
available in custom lengths. These detectors are also available in OEM modules.</p>
<h2>Specifications List</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Instrument type</th>
<td>Double-beam photometer with LED light sources</td>
</tr>
<tr>
<th>Light source</th>
<td>1 or 2 LEDs</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>240 &#8211; 1050 nm (LEDs)</td>
</tr>
<tr>
<th>Number of wavelength channels</th>
<td>LED(s): 1 single fixed, 2 rapid switching</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.5 nm (LEDs)</td>
</tr>
<tr>
<th>Wavelength precision (reproducibility)</th>
<td>± 0.5 nm</td>
</tr>
<tr>
<th>Spectral resolution</th>
<td>&lt;12 nm (LEDs)</td>
</tr>
<tr>
<th>Noise</th>
<td>&lt;± 0.3 x 10-5 AU (dry analytical cell, 260 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<th>Drift</th>
<td>&lt;± 1 x 10-4 AU (dry analytical cell, 260 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Linearity range</th>
<td>&gt; 2.5 AU</td>
</tr>
<tr>
<th>Time constant</th>
<td>0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<th>Maximal output data rate</th>
<td>100 Hz (1 wavelength)<br />
10 Hz (2 wavelengths)</td>
</tr>
<tr>
<th>Communications</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<th>Stand-alone operation</th>
<td>TFT Touchpanel</td>
</tr>
<tr>
<th>Remote operation</th>
<td>Start/Stop input<br />
Autozero input<br />
Error output<br />
Wavelength tuning analogue input, 0-10V<br />
1 Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<th>Data communication</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C (115200 baud)</td>
</tr>
<tr>
<th>Flow cells</th>
<td>10 mm path length, 2.5 µl volume (micro)<br />
10 mm path length, 8 µl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 µl volume (preparative)<br />
Other Flow cell options Available<br />
Cell material: stainless steel, titanium, PEEK<br />
Fiber optics are available for remote sensing</td>
</tr>
<tr>
<th>Power</th>
<td>External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<th>Dimensions</th>
<td>95 x 155 x 300 mm / 4.0 x 6.25 x 12.0 in. (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>1.25 kg / 2.75 lbs</td>
</tr>
</tbody>
</table>
<h2>Order information:</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>LED light source, single wavelength</th>
<td>UVL1-xxxx(wavelength)</td>
</tr>
<tr>
<th>LED light source, double wavelength</th>
<td>UVL2-xxxxxxxx(wavelengths)</td>
</tr>
</tbody>
</table>
<p>Specifications are subject to change without notice</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-uvl2-led-detectors-copy/">ANSER UVL1 / UVL2 LED Detectors</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER UVL2 LED Detector</title>
		<link>https://www.iconsci.com/shop/anser-uvl2-led-detector/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Fri, 06 Mar 2026 21:35:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4989</guid>

					<description><![CDATA[<p>Icon Scientific ANSER UV LED- 3260/3280 detectors. The Dual wavelength 260/280 LED detector uses two LEDs using novel rapid switching [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl2-led-detector/">ANSER UVL2 LED Detector</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">Icon Scientific ANSER UV LED- 3260/3280 detectors. The Dual wavelength 260/280 LED detector uses two LEDs using novel<br />
rapid switching technology. This detector can handle a wide range of flow<br />
cells covering nano liters to liters/min. flow rates. Our full range of<br />
flow cells include fiber optic flow cells with fiber optics<br />
available in custom lengths. These detectors are also available in OEM modules.</p>
<h2>Specifications List</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Instrument type</th>
<td>Double-beam photometer with LED light sources</td>
</tr>
<tr>
<th>Light source</th>
<td>260nm + 280nm LEDs</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>260nm + 280nm (LEDs)</td>
</tr>
<tr>
<th>Number of wavelength channels</th>
<td>LED(s): 1 single fixed, 2 rapid switching</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.5 nm (LEDs)</td>
</tr>
<tr>
<th>Wavelength precision (reproducibility)</th>
<td>± 0.5 nm</td>
</tr>
<tr>
<th>Spectral resolution</th>
<td>&lt;12 nm (LEDs)</td>
</tr>
<tr>
<th>Noise</th>
<td>&lt;± .3 x 10-5 AU (dry analytical cell, 260 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Drift</th>
<td>&lt;± 1 x 10-4 AU (dry analytical cell, 260 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Linearity range</th>
<td>&gt; 2.5 AU</td>
</tr>
<tr>
<th>Time constant</th>
<td>0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<th>Maximal output data rate</th>
<td>100 Hz (1 wavelength)<br />
10 Hz (2 wavelengths)</td>
</tr>
<tr>
<th>Communications</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<th>Stand-alone operation</th>
<td>TFT touchpanel</td>
</tr>
<tr>
<th>Remote operation</th>
<td>Start/Stop input<br />
Autozero input<br />
Error output<br />
1 Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<th>Data communication</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C (115200 baud)</td>
</tr>
<tr>
<th>Flow cells</th>
<td>10 mm path length, 2.5 µl volume (micro)<br />
10 mm path length, 8 µl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 µl volume (preparative)<br />
Other Flow cell options Available<br />
Cell material: titanium, PEEK<br />
Fiber optics are available for remote sensing</td>
</tr>
<tr>
<th>Power</th>
<td>External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<th>Dimensions</th>
<td>95 x 155 x 300 mm / 4.0 x 6.25 x 12.0 in. (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>1.25 kg / 2.75 lbs</td>
</tr>
</tbody>
</table>
<h2>Order information:</h2>
<table class="table-module__table" style="height: 88px;" width="586">
<tbody>
<tr>
<th>LED light source, dual wavelength</th>
<td>UVL2-02600280</td>
</tr>
<tr>
<th></th>
<td></td>
</tr>
</tbody>
</table>
<p>Specifications are subject to change without notice</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl2-led-detector/">ANSER UVL2 LED Detector</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER UVL1 / UVL2 LED Detectors</title>
		<link>https://www.iconsci.com/shop/anser-uvl1-uvl2-led-detectors/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Fri, 01 Feb 2019 15:37:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/anser-uvl1-uvl2-led-detectors/</guid>

					<description><![CDATA[<p>Icon Scientific introduces ANSER LED detectors. Our LED detectors cover the UV from 240nm to 1050nm using either a single [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-uvl2-led-detectors/">ANSER UVL1 / UVL2 LED Detectors</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">Icon Scientific introduces ANSER LED detectors. Our LED detectors cover the UV from<br />
240nm to 1050nm using either a single fixed LED or two LEDs using novel<br />
rapid switching technology. These detectors can handle a wide range of flow<br />
cells covering nano liters to liters/min. flow rates. Our full range of<br />
flow cells include fiber optic connected flow cells with fiber optics<br />
available in custom lengths. These detectors are also available in OEM modules.</p>
<h2>Specifications List</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Instrument type</th>
<td>Double-beam photometer with LED light sources</td>
</tr>
<tr>
<th>Light source</th>
<td>1 or 2 LEDs</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>240 &#8211; 1050 nm (LEDs)</td>
</tr>
<tr>
<th>Number of wavelength channels</th>
<td>LED(s): 1 single fixed, 2 rapid switching</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.5 nm (LEDs)</td>
</tr>
<tr>
<th>Wavelength precision (reproducibility)</th>
<td>± 0.5 nm</td>
</tr>
<tr>
<th>Spectral resolution</th>
<td>&lt;12 nm (LEDs)</td>
</tr>
<tr>
<th>Noise</th>
<td>LED<br />
&lt;± 0.3 x 10-5 AU (dry analytical cell, 240 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<th>Drift</th>
<td>&lt;± 1 x 10-4 AU (dry analytical cell, 240 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Linearity range</th>
<td>&gt; 2.5 AU</td>
</tr>
<tr>
<th>Time constant</th>
<td>0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<th>Maximal output data rate</th>
<td>100 Hz (1 wavelength)<br />
10 Hz (2 wavelengths)</td>
</tr>
<tr>
<th>Communications</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<th>Stand-alone operation</th>
<td>OLED display, keypad</td>
</tr>
<tr>
<th>Remote operation</th>
<td>Start/Stop input<br />
Autozero input<br />
Error output<br />
Wavelength tuning analogue input, 0-10V<br />
2x Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<th>Data communication</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C (115200 baud)</td>
</tr>
<tr>
<th>Flow cells</th>
<td>10 mm path length, 2.5 µl volume (micro)<br />
10 mm path length, 8 µl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 µl volume (preparative)<br />
Other Flow cell options Available<br />
Cell material: stainless steel, titanium, PEEK<br />
Light fiber connector option</td>
</tr>
<tr>
<th>Power</th>
<td>External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<th>Dimensions</th>
<td>127 x 130 x 350 mm / 5.0 x 5.1 x 13.7 in. (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>3 kg / 6.6 lbs (LED)</td>
</tr>
</tbody>
</table>
<h2>Order information:</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>LED light source, single wavelength</th>
<td>UVL1-xxxx(wavelength)</td>
</tr>
<tr>
<th>LED light source, double wavelength</th>
<td>UVL2-xxxxxxxx(wavelengths)</td>
</tr>
</tbody>
</table>
<p>Specifications are subject to change without notice</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-uvl2-led-detectors/">ANSER UVL1 / UVL2 LED Detectors</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
