<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>530d2 &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-tag/530d2/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Fri, 16 Sep 2022 14:24:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>530d2 &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>iPlanar Degasser &#8211; 530D2</title>
		<link>https://www.iconsci.com/shop/iplanar-degasser-530d2/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 17 Aug 2022 17:13:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4788</guid>

					<description><![CDATA[<p>Degasser channels 2 Max. flow rate/channel 30 ml/min Recommended flow rate/channel 10 ml/min Degassing method Gas permeation through dual thin [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/iplanar-degasser-530d2/">iPlanar Degasser &#8211; 530D2</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="row clearfix">
<table class="table-module__table">
<tbody>
<tr>
<th>Degasser channels</th>
<td>2</td>
</tr>
<tr>
<th>Max. flow rate/channel</th>
<td>30 ml/min</td>
</tr>
<tr>
<th>Recommended flow rate/channel</th>
<td>10 ml/min</td>
</tr>
<tr>
<th>Degassing method</th>
<td>Gas permeation through dual thin film teflon <span title="This amorphous perfluorinated copolymer is inert against all commonly used solvents. However, it is soluble in perfluorinated solvents like Fluorinert® FC-75 and FC-40, and Fomblin perfluor-polyether solvents from Ausimont. In addition, it is affected by Freon® solvents.">AF <sup>TM</sup></span> membranes</td>
</tr>
<tr>
<th>Degassing chamber volume</th>
<td>5300 µl</td>
</tr>
<tr>
<th>Wetted materials</th>
<td><span title="This amorphous perfluorinated copolymer is inert against all commonly used solvents. However, it is soluble in perfluorinated solvents like Fluorinert® FC-75 and FC-40, and Fomblin perfluor-polyether solvents from Ausimont. In addition, it is affected by Freon® solvents.">teflon AF <sup>TM</sup></span>, <span title="PEEK is a durable and resistant plastic and, apart from stainless steel, the standard material in HPLC. It can be used at temperatures up to 100 °C and is highly chemical resistant against almost all commonly used solvents in a pH range of 1-12, 5. PEEK is potentially moderate resistant against oxidizing and reducing solvents. Therefore, following solvents should not be used: Concentrated and oxidizing acids (such as nitric acid solution, sulfuric acid), halogenated acids (such as hydrofluoric acid, hydrobromic acid) and gaseous halogens. Hydrochloric acid is approved for most applications. In addition, following solvents can have a swelling effect and may have an impact on the functionality of the built-in components: Methylene chloride, THF and DMSO in any concentration such as acetonitrile in higher concentrations. ">PEEK</span></td>
</tr>
<tr>
<th>Internal fittings</th>
<td>None</td>
</tr>
</tbody>
</table>
</div>
<div class="row clearfix">
<table class="table-module__table" width="744">
<tbody>
<tr>
<th>Display</th>
<td>Touch Screen</td>
</tr>
</tbody>
</table>
<table class="techdata table" width="743">
<tbody>
<tr>
<th class="rowHeader">Liquid Connections</th>
<td>
<p class="bodytext"> 1/4-28 flat bottom ports</p>
</td>
</tr>
<tr>
<th class="rowHeader">Average pressure drop</th>
<td>
<p class="bodytext"> Less than 3 mbar (with vacuum applied)</p>
</td>
</tr>
<tr>
<th class="rowHeader">Dimensions</th>
<td>
<p class="bodytext">3 3/4″ x  10 1/2″ x 6″</p>
<p>9 1/2 cm x 27 cm x 15cm</td>
</tr>
<tr>
<th class="rowHeader">Weight</th>
<td>
<p class="bodytext">3 Lbs 1oz</p>
<p>1.4 kg</td>
</tr>
<tr>
<th class="rowHeader">Model #</th>
<td>530D2</td>
</tr>
<tr>
<th class="rowHeader">Part #</th>
<td>IC530D2</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/iplanar-degasser-530d2/">iPlanar Degasser &#8211; 530D2</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
