<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>UV Detectors &amp; Flow Cells &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/uv-detectors-flow-cells/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Tue, 10 Mar 2026 13:25:54 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>UV Detectors &amp; Flow Cells &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ANSER UVL1 Detector-3260</title>
		<link>https://www.iconsci.com/shop/anser-uvl1-detector-3260/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Tue, 10 Mar 2026 13:22:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4993</guid>

					<description><![CDATA[<p>Icon Scientific ANSER UV LED-3260 detector. The UV LED-3260 is a single fixed wavelength using a 260nm UV LED and [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-detector-3260/">ANSER UVL1 Detector-3260</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">Icon Scientific ANSER UV LED-3260 detector. The UV LED-3260 is a single fixed wavelength using a 260nm UV LED and a narrow band filter filter eliminating other bandwidths and reducing stray light. These detectors can handle a wide range of flow cells covering nano liters to liters/min. flow rates. Our full range of flow cells include fiber optic flow cells with fiber optics<br />
available in custom lengths. These detectors are also available in OEM modules.</p>
<h2>Specifications List</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Instrument type</th>
<td>Double-beam photometer with LED light source</td>
</tr>
<tr>
<th>Light source</th>
<td>260nm UV LED</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>280 nm</td>
</tr>
<tr>
<th>Number of wavelength channels</th>
<td>LED(s): 1 single fixed, 2 rapid switching</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.5 nm (LEDs)</td>
</tr>
<tr>
<th>Wavelength precision (reproducibility)</th>
<td>± 0.5 nm</td>
</tr>
<tr>
<th>Spectral resolution</th>
<td>&lt;12 nm (LEDs)</td>
</tr>
<tr>
<th>Noise</th>
<td>&lt;± 0.3 x 10-5 AU (dry analytical cell, 260 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<th>Drift</th>
<td>&lt;± 1 x 10-4 AU (dry analytical cell, 260 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Linearity range</th>
<td>&gt; 2.5 AU</td>
</tr>
<tr>
<th>Time constant</th>
<td>0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<th>Maximal output data rate</th>
<td>100 Hz</td>
</tr>
<tr>
<th>Communications</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<th>Stand-alone operation</th>
<td>TFT Touchpanel</td>
</tr>
<tr>
<th>Remote operation</th>
<td>Start/Stop input<br />
Autozero input<br />
Error output<br />
1 Absorption signal analogue output, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<th>Data communication</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C (115200 baud)</td>
</tr>
<tr>
<th>Flow cells</th>
<td>10 mm path length, 2.5 µl volume (micro)<br />
10 mm path length, 8 µl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 µl volume (preparative)<br />
Other Flow cell options Available<br />
Cell material: titanium, PEEK<br />
Fiber optics are available for remote sensing</td>
</tr>
<tr>
<th>Power</th>
<td>External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<th>Dimensions</th>
<td>95 x 155 x 300 mm / 4.0 x 6.25 x 12.0 in. (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>1.25 kg / 2.75 lbs</td>
</tr>
</tbody>
</table>
<h2>Order information:</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>LED light source, single wavelength</th>
<td>UVL1-3260</td>
</tr>
<tr>
<th></th>
<td></td>
</tr>
</tbody>
</table>
<p>Specifications are subject to change without notice</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-detector-3260/">ANSER UVL1 Detector-3260</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER UVL1 Detector</title>
		<link>https://www.iconsci.com/shop/anser-uvl1-detector/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Tue, 10 Mar 2026 13:01:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4992</guid>

					<description><![CDATA[<p>Icon Scientific ANSER UV LED-3280 detector. The UV LED-3280 is a single fixed wavelength using a 280nm UV LED and [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-detector/">ANSER UVL1 Detector</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">Icon Scientific ANSER UV LED-3280 detector. The UV LED-3280 is a single fixed wavelength using a 280nm UV LED and a narrow band filter filter eliminating other bandwidths and reducing stray light. These detectors can handle a wide range of flow cells covering nano liters to liters/min. flow rates. Our full range of flow cells include fiber optic flow cells with fiber optics<br />
available in custom lengths. These detectors are also available in OEM modules.</p>
<h2>Specifications List</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Instrument type</th>
<td>Double-beam photometer with LED light source</td>
</tr>
<tr>
<th>Light source</th>
<td>260nm UV LED</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>280 nm</td>
</tr>
<tr>
<th>Number of wavelength channels</th>
<td>LED(s): 1 single fixed, 2 rapid switching</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.5 nm (LEDs)</td>
</tr>
<tr>
<th>Wavelength precision (reproducibility)</th>
<td>± 0.5 nm</td>
</tr>
<tr>
<th>Spectral resolution</th>
<td>&lt;12 nm (LEDs)</td>
</tr>
<tr>
<th>Noise</th>
<td>&lt;± 0.3 x 10-5 AU (dry analytical cell, 280 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<th>Drift</th>
<td>&lt;± 1 x 10-4 AU (dry analytical cell, 280 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Linearity range</th>
<td>&gt; 2.5 AU</td>
</tr>
<tr>
<th>Time constant</th>
<td>0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<th>Maximal output data rate</th>
<td>100 Hz</td>
</tr>
<tr>
<th>Communications</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<th>Stand-alone operation</th>
<td>TFT Touchpanel</td>
</tr>
<tr>
<th>Remote operation</th>
<td>Start/Stop input<br />
Autozero input<br />
Error output<br />
1 Absorption signal analogue output, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<th>Data communication</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C (115200 baud)</td>
</tr>
<tr>
<th>Flow cells</th>
<td>10 mm path length, 2.5 µl volume (micro)<br />
10 mm path length, 8 µl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 µl volume (preparative)<br />
Other Flow cell options Available<br />
Cell material: titanium, PEEK<br />
Fiber optics are available for remote sensing</td>
</tr>
<tr>
<th>Power</th>
<td>External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<th>Dimensions</th>
<td>95 x 155 x 300 mm / 4.0 x 6.25 x 12.0 in. (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>1.25 kg / 2.75 lbs</td>
</tr>
</tbody>
</table>
<h2>Order information:</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>LED light source, single wavelength</th>
<td>UVL1-3280</td>
</tr>
<tr>
<th></th>
<td></td>
</tr>
</tbody>
</table>
<p>Specifications are subject to change without notice</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-detector/">ANSER UVL1 Detector</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER UVL1 / UVL2 LED Detectors</title>
		<link>https://www.iconsci.com/shop/anser-uvl1-uvl2-led-detectors-copy/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Tue, 10 Mar 2026 12:54:58 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4991</guid>

					<description><![CDATA[<p>Icon Scientific introduces ANSER LED detectors. Our LED detectors cover the UV from 240nm to 1050nm using either a single [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-uvl2-led-detectors-copy/">ANSER UVL1 / UVL2 LED Detectors</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">Icon Scientific introduces ANSER LED detectors. Our LED detectors cover the UV from<br />
240nm to 1050nm using either a single fixed LED or two LEDs using novel<br />
rapid switching technology. These detectors can handle a wide range of flow<br />
cells covering nano liters to liters/min. flow rates. Our full range of<br />
flow cells include fiber optic flow cells with fiber optics<br />
available in custom lengths. These detectors are also available in OEM modules.</p>
<h2>Specifications List</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Instrument type</th>
<td>Double-beam photometer with LED light sources</td>
</tr>
<tr>
<th>Light source</th>
<td>1 or 2 LEDs</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>240 &#8211; 1050 nm (LEDs)</td>
</tr>
<tr>
<th>Number of wavelength channels</th>
<td>LED(s): 1 single fixed, 2 rapid switching</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.5 nm (LEDs)</td>
</tr>
<tr>
<th>Wavelength precision (reproducibility)</th>
<td>± 0.5 nm</td>
</tr>
<tr>
<th>Spectral resolution</th>
<td>&lt;12 nm (LEDs)</td>
</tr>
<tr>
<th>Noise</th>
<td>&lt;± 0.3 x 10-5 AU (dry analytical cell, 260 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<th>Drift</th>
<td>&lt;± 1 x 10-4 AU (dry analytical cell, 260 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Linearity range</th>
<td>&gt; 2.5 AU</td>
</tr>
<tr>
<th>Time constant</th>
<td>0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<th>Maximal output data rate</th>
<td>100 Hz (1 wavelength)<br />
10 Hz (2 wavelengths)</td>
</tr>
<tr>
<th>Communications</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<th>Stand-alone operation</th>
<td>TFT Touchpanel</td>
</tr>
<tr>
<th>Remote operation</th>
<td>Start/Stop input<br />
Autozero input<br />
Error output<br />
Wavelength tuning analogue input, 0-10V<br />
1 Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<th>Data communication</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C (115200 baud)</td>
</tr>
<tr>
<th>Flow cells</th>
<td>10 mm path length, 2.5 µl volume (micro)<br />
10 mm path length, 8 µl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 µl volume (preparative)<br />
Other Flow cell options Available<br />
Cell material: stainless steel, titanium, PEEK<br />
Fiber optics are available for remote sensing</td>
</tr>
<tr>
<th>Power</th>
<td>External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<th>Dimensions</th>
<td>95 x 155 x 300 mm / 4.0 x 6.25 x 12.0 in. (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>1.25 kg / 2.75 lbs</td>
</tr>
</tbody>
</table>
<h2>Order information:</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>LED light source, single wavelength</th>
<td>UVL1-xxxx(wavelength)</td>
</tr>
<tr>
<th>LED light source, double wavelength</th>
<td>UVL2-xxxxxxxx(wavelengths)</td>
</tr>
</tbody>
</table>
<p>Specifications are subject to change without notice</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl1-uvl2-led-detectors-copy/">ANSER UVL1 / UVL2 LED Detectors</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER UVL2 LED Detector</title>
		<link>https://www.iconsci.com/shop/anser-uvl2-led-detector/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Fri, 06 Mar 2026 21:35:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4989</guid>

					<description><![CDATA[<p>Icon Scientific ANSER UV LED- 3260/3280 detectors. The Dual wavelength 260/280 LED detector uses two LEDs using novel rapid switching [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl2-led-detector/">ANSER UVL2 LED Detector</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">Icon Scientific ANSER UV LED- 3260/3280 detectors. The Dual wavelength 260/280 LED detector uses two LEDs using novel<br />
rapid switching technology. This detector can handle a wide range of flow<br />
cells covering nano liters to liters/min. flow rates. Our full range of<br />
flow cells include fiber optic flow cells with fiber optics<br />
available in custom lengths. These detectors are also available in OEM modules.</p>
<h2>Specifications List</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Instrument type</th>
<td>Double-beam photometer with LED light sources</td>
</tr>
<tr>
<th>Light source</th>
<td>260nm + 280nm LEDs</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>260nm + 280nm (LEDs)</td>
</tr>
<tr>
<th>Number of wavelength channels</th>
<td>LED(s): 1 single fixed, 2 rapid switching</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.5 nm (LEDs)</td>
</tr>
<tr>
<th>Wavelength precision (reproducibility)</th>
<td>± 0.5 nm</td>
</tr>
<tr>
<th>Spectral resolution</th>
<td>&lt;12 nm (LEDs)</td>
</tr>
<tr>
<th>Noise</th>
<td>&lt;± .3 x 10-5 AU (dry analytical cell, 260 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Drift</th>
<td>&lt;± 1 x 10-4 AU (dry analytical cell, 260 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<th>Linearity range</th>
<td>&gt; 2.5 AU</td>
</tr>
<tr>
<th>Time constant</th>
<td>0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<th>Maximal output data rate</th>
<td>100 Hz (1 wavelength)<br />
10 Hz (2 wavelengths)</td>
</tr>
<tr>
<th>Communications</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<th>Stand-alone operation</th>
<td>TFT touchpanel</td>
</tr>
<tr>
<th>Remote operation</th>
<td>Start/Stop input<br />
Autozero input<br />
Error output<br />
1 Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<th>Data communication</th>
<td>LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C (115200 baud)</td>
</tr>
<tr>
<th>Flow cells</th>
<td>10 mm path length, 2.5 µl volume (micro)<br />
10 mm path length, 8 µl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 µl volume (preparative)<br />
Other Flow cell options Available<br />
Cell material: titanium, PEEK<br />
Fiber optics are available for remote sensing</td>
</tr>
<tr>
<th>Power</th>
<td>External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<th>Dimensions</th>
<td>95 x 155 x 300 mm / 4.0 x 6.25 x 12.0 in. (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>1.25 kg / 2.75 lbs</td>
</tr>
</tbody>
</table>
<h2>Order information:</h2>
<table class="table-module__table" style="height: 88px;" width="586">
<tbody>
<tr>
<th>LED light source, dual wavelength</th>
<td>UVL2-02600280</td>
</tr>
<tr>
<th></th>
<td></td>
</tr>
</tbody>
</table>
<p>Specifications are subject to change without notice</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-uvl2-led-detector/">ANSER UVL2 LED Detector</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-2001F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2001f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 20:08:32 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4988</guid>

					<description><![CDATA[<p>ANSER MWD-2001F Technical specifications Instrument type Double-beam photometer Light source D2 Lamp, Fiber Optics Wavelength range 190 &#8211; 420 nm [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2001f/">ANSER MWD-2001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2001F</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 Lamp, Fiber Optics</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote Fiber Optic connectors</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2001f/">ANSER MWD-2001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-2001</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2001/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 20:06:49 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4987</guid>

					<description><![CDATA[<p>ANSER MWD-2001 Technical specifications Instrument type Double-beam photometer Light source D2 Lamp Wavelength range 190 &#8211; 420 nm Number of [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2001/">ANSER MWD-2001</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2001</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 Lamp</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Accepts standard flow cells</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2001/">ANSER MWD-2001</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1001F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-1001f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 20:04:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4986</guid>

					<description><![CDATA[<p>ANSER MWD-1001F Technical specifications Instrument type Double-beam photometer Light source D2 Lamp, Fiber Optic Wavelength range 190 &#8211; 420 nm [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1001f/">ANSER MWD-1001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-1001F</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 Lamp, Fiber Optic</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote Fiber Optic connectors</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1001f/">ANSER MWD-1001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1001</title>
		<link>https://www.iconsci.com/shop/anser-mwd-1001/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 20:02:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4985</guid>

					<description><![CDATA[<p>ANSER MWD-1001 Technical specifications Instrument type Double-beam photometer Light source D2 Lamp Wavelength range 190 &#8211; 420 nm Number of [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1001/">ANSER MWD-1001</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-1001</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 Lamp</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Accepts standard flow cells</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1001/">ANSER MWD-1001</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1002F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-1002f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 19:53:10 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4983</guid>

					<description><![CDATA[<p>ANSER MWD-1002F Technical specifications Instrument type Double-beam photometer Light source D2 &#38; Tungsten Halogen, Fiber Optics Wavelength range 190 &#8211; [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1002f/">ANSER MWD-1002F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-1002F</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 &amp; Tungsten Halogen, Fiber Optics</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote, fiber optic connectors</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1002f/">ANSER MWD-1002F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1002</title>
		<link>https://www.iconsci.com/shop/anser-mwd-1002/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 19:51:36 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4982</guid>

					<description><![CDATA[<p>ANSER MWD-1002 Technical specifications Instrument type Double-beam photometer Light source D2 &#38; Tungsten Halogen Wavelength range 190 &#8211; 750 nm [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1002/">ANSER MWD-1002</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-1002</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 &amp; Tungsten Halogen</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Accepts standard flow cells</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1002/">ANSER MWD-1002</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-2002</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2002-2/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 19:49:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4981</guid>

					<description><![CDATA[<p>ANSER MWD-2002 Technical specifications Instrument type Double-beam photometer Light source D2 &#38; Tungsten Halogen Wavelength range 190 &#8211; 750 nm [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2002-2/">ANSER MWD-2002</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2002</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 &amp; Tungsten Halogen</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Accepts standard flow cells</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2002-2/">ANSER MWD-2002</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-1003F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-1003f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 19:22:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4980</guid>

					<description><![CDATA[<p>Technical specifications Instrument type Double-beam photometer Light source Xenon flash lamp, Fiber Optic Wavelength range 190 &#8211; 750 nm Number [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1003f/">ANSER MWD-1003F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Xenon flash lamp, Fiber Optic</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 2 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote, light fiber optics connectors</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">95 x 160 x 280 mm / 3.75 x 6.5 x 11.0 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-1003f/">ANSER MWD-1003F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-2002F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2002f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 16:28:50 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4978</guid>

					<description><![CDATA[<p>ANSER MWD-2002F Technical specifications Instrument type Double-beam photometer Light source D2 &#38; Tungsten Halogen, Fiber Optics Wavelength range 190 &#8211; [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2002f/">ANSER MWD-2002F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2002F</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">D2 &amp; Tungsten Halogen, Fiber Optics</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote, fiber optic connectors</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269"> 130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2002f/">ANSER MWD-2002F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER MWD-2003F</title>
		<link>https://www.iconsci.com/shop/anser-mwd-2003f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 16:23:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4976</guid>

					<description><![CDATA[<p>ANSER MWD-2003F Technical specifications Instrument type Double-beam photometer Light source Xenon flash lamp, Fiber Optics Wavelength range 190 &#8211; 750 [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2003f/">ANSER MWD-2003F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER MWD-2003F</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam photometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Xenon flash lamp, Fiber Optics</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 &#8211; 4 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 1.0 x 10<sup>-3</sup> AU (dry analytical cell, 255 nm, 1s rise time)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10<sup>-3</sup> AU/h (dry analytical cell, 255 nm, 1 hour after power-up)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">1 / 2 / 5 / 10 / 20 / 50 / 100 Hz</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">&#8211; LAN 10 / 100 Mbit/s</p>
<p>&#8211; USB (virtual COM port)</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">TFT touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Autozero digital input</p>
<p>Start digital input</p>
<p>Analog input to control wavelength</p>
<p>Analog output for signal</td>
</tr>
<tr>
<td width="128"><strong>Flow cell</strong></td>
<td width="269">Remote, fiber optic connectors</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 1 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">95 x 160 x 280 mm / 3.75 x 6.5 x 11.0 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">2 kg / 4,5 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-mwd-2003f/">ANSER MWD-2003F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER VWD-1003</title>
		<link>https://www.iconsci.com/shop/anser-vwd-1003/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Thu, 20 Nov 2025 15:50:42 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4961</guid>

					<description><![CDATA[<p>ANSER VWD- 1003 UV/UV-Vis Photometric Detectors UV-Detector with Xenon flash lamp light source (UV/VIS range 190-750 nm) Technical specifications Instrument [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1003/">ANSER VWD-1003</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER VWD- 1003 UV/UV-Vis</strong><br />
<strong>Photometric Detectors</strong></p>
<p>UV-Detector with Xenon flash lamp light source (UV/VIS range 190-750 nm)</p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam spectrophotometer with Xenon flash lamp</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Xenon flash lamp</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">UV/VIS, 190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm at 254 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 2.5 x 10-5 AU (dry analytical cell, 240 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10-4 AU (dry analytical cell, 240 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">100 Hz (1 wavelength</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">4“ LCD touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Start/Stop input<br />
Autozero input<br />
Error output<br />
Wavelength tuning analogue input, 0-10V<br />
2x Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<td width="128"><strong>Flow cells</strong></td>
<td width="269">10 mm path length, 2.5 μl volume (micro)<br />
10 mm path length, 8 μl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 μl volume (preparative)<br />
Other flow cells upon request<br />
Cell material: stainless steel, titanium, PEEK<br />
Fiber optic flow cell</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">95 x 160 x 300 mm / 3.75 x 6.25 x 12.0 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">5 kg / 11 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1003/">ANSER VWD-1003</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER VWD-1002</title>
		<link>https://www.iconsci.com/shop/anser-vwd-1002/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Thu, 20 Nov 2025 15:37:46 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4960</guid>

					<description><![CDATA[<p>ANSER VWD- 1002 Photometric Detectors UV-Detector with Deuterium lamp light source + Tungsten Halogen lamp, variable wavelength (UV/VIS range 190-750 [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1002/">ANSER VWD-1002</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER VWD- 1002</strong><br />
<strong>Photometric Detectors</strong></p>
<p>UV-Detector with Deuterium lamp light source + Tungsten Halogen lamp, variable wavelength (UV/VIS range 190-750 nm)</p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam spectrophotometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Deuterium and Tungsten halogen lamps</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">UV/VIS, 190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 0.3 x 10-5 AU (dry analytical cell, 240 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10-4 AU (dry analytical cell, 240 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">100 Hz (1 wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">4“ LCD touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Start/Stop input<br />
Autozero input<br />
Error output<br />
Wavelength tuning analogue input, 0-10V<br />
2x Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<td width="128"><strong>Flow cells</strong></td>
<td width="269">10 mm path length, 2.5 μl volume (micro)<br />
10 mm path length, 8 μl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 μl volume (preparative)<br />
Other flow cells upon request<br />
Cell material: stainless steel, titanium, PEEK<br />
Fiber optic flow cell</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">127 x 178x 350 mm / 5.0 x 7.0 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">5 kg / 11 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1002/">ANSER VWD-1002</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER VWD-1001</title>
		<link>https://www.iconsci.com/shop/anser-vwd-1001/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Thu, 20 Nov 2025 15:26:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4959</guid>

					<description><![CDATA[<p>ANSER VWD- 1001 Photometric Detectors UV-Detector with Deuterium lamp light source, variable wavelength (UV range 190-420 nm) Technical specifications Instrument [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1001/">ANSER VWD-1001</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER VWD- 1001</strong><br />
<strong>Photometric Detectors</strong></p>
<p>UV-Detector with Deuterium lamp light source, variable wavelength (UV range 190-420 nm)</p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam spectrophotometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Deuterium lamps</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">UV/VIS, 190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 0.3 x 10-5 AU (dry analytical cell, 240 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10-4 AU (dry analytical cell, 240 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">100 Hz (1 wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">4“ LCD touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Start/Stop input<br />
Autozero input<br />
Error output<br />
Wavelength tuning analogue input, 0-10V<br />
2x Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<td width="128"><strong>Flow cells</strong></td>
<td width="269">10 mm path length, 2.5 μl volume (micro)<br />
10 mm path length, 8 μl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 μl volume (preparative)<br />
Other flow cells upon request<br />
Cell material: stainless steel, titanium, PEEK<br />
Fiber optic flow cell</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">127 x 178x 350 mm / 5.0 x 7.0 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">5 kg / 11 lbs.</td>
</tr>
<tr>
<td width="128"><strong>Data communication</strong></td>
<td width="269">LAN 10 / 100 Mbit/s USB 2.0 RS-232-C (115200 baud)</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1001/">ANSER VWD-1001</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER VWD-1001F</title>
		<link>https://www.iconsci.com/shop/anser-vwd-1001f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Thu, 20 Nov 2025 14:41:56 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4958</guid>

					<description><![CDATA[<p>ANSER VWD- 1001F Photometric Detectors UV-Detector with Deuterium lamp light source, variable wavelength (UV range 190-420 nm) Technical specifications Instrument [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1001f/">ANSER VWD-1001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER VWD- 1001F</strong><br />
<strong>Photometric Detectors</strong></p>
<p>UV-Detector with Deuterium lamp light source, variable wavelength (UV range 190-420 nm)</p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam spectrophotometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Deuterium lamps</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">UV/VIS, 190 &#8211; 420 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 0.3 x 10-5 AU (dry analytical cell, 240 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10-4 AU (dry analytical cell, 240 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">100 Hz (1 wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">4“ LCD touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Start/Stop input<br />
Autozero input<br />
Error output<br />
Wavelength tuning analogue input, 0-10V<br />
2x Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<td width="128"><strong>Flow cells</strong></td>
<td width="269">10 mm path length, 2.5 μl volume (micro)<br />
10 mm path length, 8 μl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 μl volume (preparative)<br />
Other flow cells upon request<br />
Cell material: stainless steel, titanium, PEEK<br />
Fiber optic flow cell</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">127 x 178x 350 mm / 5.0 x 7.0 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">5 kg / 11 lbs.</td>
</tr>
<tr>
<td width="128"><strong>Data communication</strong></td>
<td width="269">LAN 10 / 100 Mbit/s USB 2.0 RS-232-C (115200 baud)</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1001f/">ANSER VWD-1001F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER VWD-1002F</title>
		<link>https://www.iconsci.com/shop/anser-vwd-1002f/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Thu, 20 Nov 2025 14:20:43 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4957</guid>

					<description><![CDATA[<p>ANSER VWD- 1002F Photometric Detectors Technical specifications Instrument type Double-beam spectrophotometer Light source Deuterium and Tungsten halogen lamps Wavelength range [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1002f/">ANSER VWD-1002F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>ANSER VWD- 1002F</strong><br />
<strong>Photometric Detectors</strong></p>
<p><strong>Technical specifications</strong></p>
<table style="font-weight: 400;" width="397">
<tbody>
<tr>
<td width="128"><strong>Instrument type</strong></td>
<td width="269">Double-beam spectrophotometer</td>
</tr>
<tr>
<td width="128"><strong>Light source</strong></td>
<td width="269">Deuterium and Tungsten halogen lamps</td>
</tr>
<tr>
<td width="128"><strong>Wavelength range</strong></td>
<td width="269">UV/VIS, 190 &#8211; 750 nm</td>
</tr>
<tr>
<td width="128"><strong>Number of wavelength channels</strong></td>
<td width="269">1 variable</td>
</tr>
<tr>
<td width="128"><strong>Wavelength accuracy</strong></td>
<td width="269">± 1.0 nm</p>
<p>&nbsp;</td>
</tr>
<tr>
<td width="128"><strong>Wavelength precision (reproducibility)</strong></td>
<td width="269">± 0.5 nm</td>
</tr>
<tr>
<td width="128"><strong>Spectral resolution</strong></td>
<td width="269">&lt;6 nm</td>
</tr>
<tr>
<td width="128"><strong>Noise</strong></p>
<p>&nbsp;</td>
<td width="269">&lt;± 0.3 x 10-5 AU (dry analytical cell, 240 nm, 1s rise time, single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Drift</strong></td>
<td width="269">&lt;± 1 x 10-4 AU (dry analytical cell, 240 nm, 1s rise time,<br />
single wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Linearity range</strong></td>
<td width="269">&gt; 2.5 AU</td>
</tr>
<tr>
<td width="128"><strong>Response time</strong></td>
<td width="269">0.0 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 s</td>
</tr>
<tr>
<td width="128"><strong>Output data rate</strong></td>
<td width="269">100 Hz (1 wavelength)</td>
</tr>
<tr>
<td width="128"><strong>Communications</strong></td>
<td width="269">LAN 10 / 100 Mbit/s<br />
USB 2.0<br />
RS-232-C</td>
</tr>
<tr>
<td width="128"><strong>Stand-alone operation</strong></td>
<td width="269">4“ LCD touch panel</td>
</tr>
<tr>
<td width="128"><strong>Remote operation</strong></td>
<td width="269">Start/Stop input<br />
Autozero input<br />
Error output<br />
Wavelength tuning analogue input, 0-10V<br />
2x Absorption signal analogue outputs, ±2.5 V, 24 bits resolution</td>
</tr>
<tr>
<td width="128"><strong>Flow cells</strong></td>
<td width="269">10 mm path length, 2.5 μl volume (micro)<br />
10 mm path length, 8 μl volume (analytical)<br />
0.5 &#8211; 2 mm path length, 2 &#8211; 8 μl volume (preparative)<br />
Other flow cells upon request<br />
Cell material: stainless steel, titanium, PEEK<br />
Fiber optic flow cell</td>
</tr>
<tr>
<td width="128"><strong>Power</strong></td>
<td width="269">External power supply, 24 Vdc, 2.5 A max.</td>
</tr>
<tr>
<td width="128"><strong>Dimensions</strong></td>
<td width="269">127 x 178x 350 mm / 5.0 x 7.0 x 13.7 in.</p>
<p>(W x H x D)</td>
</tr>
<tr>
<td width="128"><strong>Weight</strong></td>
<td width="269">5 kg / 11 lbs.</td>
</tr>
<tr>
<td width="128"></td>
<td width="269"></td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-vwd-1002f/">ANSER VWD-1002F</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Single Wavelength UV Detector for Liquid Chromatography and Process Technology</title>
		<link>https://www.iconsci.com/shop/single-wavelength-uv-detector-for-liquid-chromatography-and-process-technology/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Fri, 30 Sep 2022 20:56:42 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4808</guid>

					<description><![CDATA[<p>The BlueShadow detector 40D is a competitively priced HPLC spectrophotometer for routine HPLC applications including fast LC methods. Besides offering [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/single-wavelength-uv-detector-for-liquid-chromatography-and-process-technology/">Single Wavelength UV Detector for Liquid Chromatography and Process Technology</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The BlueShadow detector 40D is a competitively priced HPLC spectrophotometer for routine HPLC applications including fast LC methods. Besides offering excellent technical specifications, this robust detector features a highly flexible and compact design. The BlueShadow Detector 40D comes with an installed deuterium lamp which covers a wavelength range from 190 to 750 nm. This detector can be controlled with ClarityChrom® software, as well as from the keypad (stand-alone operation), via LAN, via RS-232, or through analog input/output. Due to a smart design the flow cell is easily accessible and can be changed very quickly. You can choose between a wide range of flow cells for analytical or preparative LC applications with flow rates from 10 μl/min up to 10 l/min.</p>
<h2 style="text-align: center;"><b>Technical Data</b></h2>
<section class="table-module">
<div class="container">
<div class="row clearfix">
<h3 class="table-module__header">Detection</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>Detector type</th>
<td>Variable single wavelength UV detector</td>
</tr>
<tr>
<th>Detection channels</th>
<td>1</td>
</tr>
<tr>
<th>Light source</th>
<td>Deuterium (D<sub>2</sub>) lamp with integrated GLP chip</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>190 &#8211; 750 nm</td>
</tr>
<tr>
<th>Spectral bandwidth</th>
<td>11 nm at H<sub>α</sub> line (FWHM)</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2.5 nm</td>
</tr>
<tr>
<th>Wavelength precision</th>
<td>0.3 nm (ASTM E275-93)</td>
</tr>
<tr>
<th>Noise</th>
<td>± 15 µAU at 254 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Drift</th>
<td>300 µAU/h at 254 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Linearity</th>
<td>&gt; 2.0 AU at 270 nm (ASTM E1657-98)</td>
</tr>
<tr>
<th>Maximum data rate</th>
<td>50 Hz (LAN)/20 Hz (Analog)/10 Hz (RS-232)</td>
</tr>
<tr>
<th>Flow cell</th>
<td>Not included</td>
</tr>
<tr>
<th>Time constants</th>
<td>0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s</td>
</tr>
<tr>
<th>Integration time</th>
<td>Automatic</td>
</tr>
</tbody>
</table>
</div>
<div class="row clearfix">
<h3 class="table-module__header">Communication</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>Error (IN), Start (IN), Autozero, 0 &#8211; 10 V Analog IN</td>
</tr>
<tr>
<th>Outputs</th>
<td>Events 1 &#8211; 3, + 5 V, 24 V Valve</td>
</tr>
<tr>
<th>Analog outputs</th>
<td>1 x 0 &#8211; 5 V scalable, 20 bit, offset adjustable</td>
</tr>
<tr>
<th>Control</th>
<td>Digital: LAN-DHCP, RS-232, remote connector/Analog: wavelength control/Manual: keypad</td>
</tr>
<tr>
<th>Programming</th>
<td>Timed: wavelength, events, fraction valve, links, wake up (program, link); /9 programs, 50 program lines</td>
</tr>
</tbody>
</table>
</div>
<div class="row clearfix">
<h3 class="table-module__header">Technical parameters</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>GLP</th>
<td>Detailed report including lamp recognition, operating hours, lamp operating hours, number of lamp ignitions</td>
</tr>
<tr>
<th>Display</th>
<td>Matrix display with keypad</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>Temperature range: 4 – 40 °C; 39.2 – 104 °F, Air humidity: below 90 % noncondensing</td>
</tr>
</tbody>
</table>
</div>
<div class="row clearfix">
<h3 class="table-module__header">General</h3>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 – 240 V, 50 – 60 Hz, 75 W</td>
</tr>
<tr>
<th>Dimensions</th>
<td>242 x 169 x 399 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>5.3 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</section>
<section id="related-product-grid-static" data-init-list="true" data-per-page="4">
<div class="container"></div>
</section>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/single-wavelength-uv-detector-for-liquid-chromatography-and-process-technology/">Single Wavelength UV Detector for Liquid Chromatography and Process Technology</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
