<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>sugar purification system &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/uhplc-systems/sugar-purification-system-uhplc-systems/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Fri, 29 May 2020 21:21:38 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>sugar purification system &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AZURA System for Sugar Analysis</title>
		<link>https://www.iconsci.com/shop/azurasystemforsugaranalysis/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Tue, 28 Aug 2018 15:21:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/azurasystemforsugaranalysis/</guid>

					<description><![CDATA[<p>Dedicated system</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurasystemforsugaranalysis/">AZURA System for Sugar Analysis</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">Dedicated system</p>
<p align="justify">Carbohydrates, alcohols, and organic acids are important in the manufacture of many foods, pharmaceuticals, and biofuels. This dedicated system is specially designed to separate and analyze these compounds. The heart of this system is the superior AZURA refractive index detector RID 2.1L with an outstanding linear range and sensitivity. More systems components are the column thermostat CT 2.1 and the isocratic AZURA pump P 6.1L for delivery of small flow rates (0.001 -10 ml/min) and pressure up to 700 bar. This price attractive system is developed to run simple and rapid methods that enable simultaneous determination of sugars, organic acids and alcohols. Therefore, an interesting application is the analysis of all major wine compounds (see our application note) for quality control.</p>
<h2 class="headline">Technical Data</h2>
<div class="ginfo">
<h2 class="table-module__header">Analytical system</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Application area</th>
<td>HPLC</td>
</tr>
<tr>
<th>Pump system</th>
<td>Isocratic</td>
</tr>
<tr>
<th>Gradient</th>
<td>None</td>
</tr>
<tr>
<th>Injection</th>
<td>Handinjection</td>
</tr>
<tr>
<th>Detector</th>
<td>Refractive index detection RI</td>
</tr>
<tr>
<th>Software</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>Pressure</th>
<td>700 bar</td>
</tr>
<tr>
<th>Column thermostat</th>
<td>Yes</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/g_e_AZURA_System_Selection_Guide_V7857US.jpeg" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/g_e_AZURA_System_Selection_Guide_V7857US.jpeg" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA System Selection Guide (V7857US)</h2>
<p class="list-download__subline">AZURA System Selection Guide, V7857US</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Brochure</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">1.3 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/g_e_AZURA_System_Selection_Guide_V7857US.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurasystemforsugaranalysis/">AZURA System for Sugar Analysis</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>