<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ClarityChrom CDS &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/software/claritychrom-cds/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Fri, 22 May 2020 21:28:50 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>ClarityChrom CDS &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ClarityChrom Prep 7.2 Extension</title>
		<link>https://www.iconsci.com/shop/claritychromprep72extension/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 22:12:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychromprep72extension/</guid>

					<description><![CDATA[<p>additional instrument license one additional time base</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychromprep72extension/">ClarityChrom Prep 7.2 Extension</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Additional instrument license for one additional time base/system</p>
<p>Additional instrument license for a workstation license; adds one additional time base/system. Already existing extensions, as PDA, must not be added again to be available for the additional system.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChromPrep</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>Fraction collection, Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC</td>
</tr>
</tbody>
</table>
</div>
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychromprep72extension/">ClarityChrom Prep 7.2 Extension</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2 Extension</title>
		<link>https://www.iconsci.com/shop/claritychrom72extension/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 19:36:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72extension/</guid>

					<description><![CDATA[<p>University package: one Offline license for data evaluation foc</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72extension/">ClarityChrom 7.2 Extension</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>University package: one Offline license for data evaluation foc</p>
<p>The university package is a promotional offer for universities. It includes one Offline license for data evaluation free of charge. The university package must be ordered along with the ClarityChrom license (A1670-11); it cannot be ordered later on. A registration (university with name, address and institute) is required if the package is ordered. In contrast to the regular Offline license, all license extensions ordered for the ClarityChrom license, as PDA, are covered. The university package Offline license does not work with ClarityChromPrep.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC</td>
</tr>
<tr>
<th>System architecture</th>
<td>32-bit CDS</td>
</tr>
<tr>
<th>Operating system</th>
<td>Windows 10, Windows 7, Windows 8/8.1, Windows Vista SP2, all 32- and 64-bit; Windows XP SP3 (32-bit only)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72extension/">ClarityChrom 7.2 Extension</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2 Extension</title>
		<link>https://www.iconsci.com/shop/claritychrom72extension-a1673-11/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 19:18:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72extension-a1673-11/</guid>

					<description><![CDATA[<p>for autosampler control</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72extension-a1673-11/">ClarityChrom 7.2 Extension</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>adds Autosampler Control Modul to educational license</p>
<p>ClarityChrom extension for autosampler control enables the control of supported autosamplers. This extension is only available for ClarityChrom Educational System license; all other ClarityChrom full licenses (workstations) always include the autosampler control.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72extension-a1673-11/">ClarityChrom 7.2 Extension</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom to ClarityChrom Prep 7.2 Upgrade</title>
		<link>https://www.iconsci.com/shop/claritychromtoclaritychromprep72upgrade/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 19:14:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychromtoclaritychromprep72upgrade/</guid>

					<description><![CDATA[<p>Upgrade for one system from ClarityChrom to ClarityChrom Prep 7.2</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychromtoclaritychromprep72upgrade/">ClarityChrom to ClarityChrom Prep 7.2 Upgrade</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Upgrade for one system from ClarityChrom to ClarityChrom Prep 7.2</p>
<p>Upgrade for one system from former version of ClarityChrom to ClarityChrom Prep 7.2. This version upgrade also covers all extensions and Offline licenses, sold for the ClarityChrom. For an upgrade please always include your dongle serial number in the order.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChromPrep</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>Fraction collection, Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC</td>
</tr>
<tr>
<th>System architecture</th>
<td>32-bit CDS</td>
</tr>
<tr>
<th>Operating system</th>
<td>Windows 10, Windows 7, Windows 8/8.1, Windows Vista SP2, all 32- and 64-bit; Windows XP SP3 (32-bit only)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychromtoclaritychromprep72upgrade/">ClarityChrom to ClarityChrom Prep 7.2 Upgrade</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom Prep 7.2 Option</title>
		<link>https://www.iconsci.com/shop/claritychromprep72option/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 19:10:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychromprep72option/</guid>

					<description><![CDATA[<p>offline license for data evaluation</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychromprep72option/">ClarityChrom Prep 7.2 Option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Offline license for data evaluation</p>
<p>ClarityChromPrep Offline license for data evaluation for a separate computer. Additional extensions, as PDA, must be ordered separately. This Offline license only works with ClarityChromPrep; for ClarityChrom a separate offline license is available.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChromPrep</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>Fraction collection, Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC</td>
</tr>
<tr>
<th>System architecture</th>
<td>32-bit CDS</td>
</tr>
<tr>
<th>Operating system</th>
<td>Windows 10, Windows 7, Windows 8/8.1, Windows Vista SP2, all 32- and 64-bit; Windows XP SP3 (32-bit only)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychromprep72option/">ClarityChrom Prep 7.2 Option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom Prep 7.2</title>
		<link>https://www.iconsci.com/shop/claritychromprep72/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 18:52:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychromprep72/</guid>

					<description><![CDATA[<p>single instrument license one time base</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychromprep72/">ClarityChrom Prep 7.2</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Single instrument license, one time base</p>
<p>ClarityChromPrep is an easy-to-use Chromatography Data System for workstations. It includes the full functionality of our ClarityChrom workstation, but also includes  the KNAUER fraction collector control and fractionation option. The optional extensions for GC control, PDA, SST, GPC and MS allow to use the software for a wide spectrum of application. All KNAUER devices with a control interface can be controlled. Additionally, devices and systems from more than 45 manufacturers are supported.</p>
<p>The ClarityChromPrep also includes the drivers of several fraction collectors and supports the peak recognition by level and/or slope as well as fractionation by time. In the fraction collector configuration the delay and the fraction vial volume can be defined. This ensures that the target substance will be collected in the fraction vial and the fraction vial will not overflow.  If a chromatogram of your separation already exists, the required fractionation commands can be derived directly from the chromatogram with a double mouse-click. The rack view gives an overview of the already collected fraction and their volume. It also includes links to the matching chromatograms of the fractions; with a double mouse-click the chromatogram can be opened. The manual fraction control, the option to use the KNAUER electric valves for fractionation and mass-triggered fractionation with the supported QUAD-MS gives you more flexibility. The combination of virtual detector and virtual fraction collector allows for optimizing the fractionation settings from an existing chromatogram of your separations without any physically existing device and, therefore, without the loss of solvent or target substance.</p>
<p>This license allows for control of one system.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChromPrep</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>Fraction collection, Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC</td>
</tr>
<tr>
<th>System architecture</th>
<td>32-bit CDS</td>
</tr>
<tr>
<th>Operating system</th>
<td>Windows 10, Windows 7, Windows 8/8.1, Windows Vista SP2, all 32- and 64-bit; Windows XP SP3 (32-bit only)</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Expandability</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Stand-alone</th>
<td>Workstation version, max. 4 systems controlled by one computer, max. 3 complete systems, max. 2 systems with PDA detector</td>
</tr>
<tr>
<th>Client/server</th>
<td>No Client/Server functionality</td>
</tr>
<tr>
<th>Multi-user environment</th>
<td>Selectable system of user accounts with independently customizable behavior and appearance for individual users</td>
</tr>
<tr>
<th>Network environment</th>
<td>Easy offline data sharing (at the file level) among all stations in a local network</td>
</tr>
<tr>
<th>Fields of application</th>
<td>Analytical HPLC, GPC/SEC, GC, MS</td>
</tr>
<tr>
<th>Supported instruments</th>
<td>All Knauer devices are supported, driver for devices from many other manufacturers are available</td>
</tr>
<tr>
<th>Instrument connection</th>
<td>Supports RS-232, Ethernet, PCI interface card, A/D-D/A interface</td>
</tr>
<tr>
<th>Recommended PC hardware</th>
<td>Pentium 2 GHz, 2 GB RAM, 10 GB free hard disk space, separate graphics card if one PC should control more than one system, 4 GB RAM recommended for PDA detectors</td>
</tr>
<tr>
<th>Graphics capabilities</th>
<td>Multiple chromatogram view and overlay, PDA view</td>
</tr>
<tr>
<th>Integration</th>
<td>27 integration parameters (peak width, threshold, tangent slope ratio etc.) integration parameters programmable in time, automatic re-integration</td>
</tr>
<tr>
<th>Calculation types</th>
<td>with/without calibration (int./ext. standard method)</td>
</tr>
<tr>
<th>Security and GLP</th>
<td>Installation qualification test of the software; FDA 21 CFR Part 11 conformance, validation with virtual detector</td>
</tr>
<tr>
<th>Instrument control</th>
<td>method-based instrument control, Instrument status display and Direct-Control mode, </td>
</tr>
<tr>
<th>Calibration</th>
<td>6 types of calibration curves, up to 20 levels, reference peaks, groups, unlimited number of standards (peaks), LOD, LOQ</td>
</tr>
<tr>
<th>Chromatogram operations</th>
<td>Overlay view, custom labels and settings, also applying mathematical operations to chromatograms</td>
</tr>
<tr>
<th>Automation</th>
<td>Sequences, automatic launch of selected commands or applications immediately following chromatogram acquisition – Post run, Batch</td>
</tr>
<tr>
<th>Presentation of results</th>
<td>Integrated customizable table of results, columns with userdefined calculation, summary table, and export in text or database format</td>
</tr>
<tr>
<th>Calculations</th>
<td>Custom: 12 predefined mathematical operators, 15 basic and 4 summary functions, special: Kovats indexes for GC, determination of noise/drift, performance calculations</td>
</tr>
<tr>
<th>Data import and export</th>
<td>ASCII, AIA, dBase</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">Additional options/extensions</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>FRC option</th>
<td>for preparative HPLC, adds tools for detector controlled and mass-triggered fraction collection, solvent recycling</td>
</tr>
<tr>
<th>FRC features</th>
<td>Fractionation can be controlled by time (volume), level, slope including AND/OR combination of these criteria, manual control of fractionation during a run</td>
</tr>
<tr>
<th>PDA option</th>
<td>separate license option; 3D chromatogram, peak purity analysis, spectrum search in self-made or commercial spectra library</td>
</tr>
<tr>
<th>GPC/SEC option</th>
<td>separate license option; molecular weight determination in size exclusion chromatography with various calibration methods</td>
</tr>
<tr>
<th>System suitability test</th>
<td>separate license option; automates the calculation of system suitability parameters for system validation</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v1670-11_claritychrom_benutzerhandbuch_de_v6.0.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/v1670-11_claritychrom_benutzerhandbuch_de_v6.0.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">ClarityChrom 7.2.0 Software Handbuch DE (V1670-11)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">6.1 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/v1670-11_claritychrom_benutzerhandbuch_de_v6.0.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">ClarityChrom 7.2.0 Software Manual EN (V1670-11A)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">7.3 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychromprep72/">ClarityChrom Prep 7.2</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom or ClarityChromPrep 7.2 Upgrade</title>
		<link>https://www.iconsci.com/shop/claritychromorclaritychromprep72upgrade/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 18:51:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychromorclaritychromprep72upgrade/</guid>

					<description><![CDATA[<p>Upgrade for one system from former version of ClarityChrom or ClarityChromPrep to the latest version ClarityChrom 7.2 or ClarityChromPrep 7.2</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychromorclaritychromprep72upgrade/">ClarityChrom or ClarityChromPrep 7.2 Upgrade</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Upgrade for one system from former version of ClarityChrom or ClarityChromPrep to the latest version ClarityChrom 7.2 or ClarityChromPrep, version 7.2</p>
<p>Upgrade for one system from former version of ClarityChrom to ClarityChrom 7.2 or ClarityChromPrep to ClarityChromPrep 7.2. This version upgrade also covers all license extensions and Offline licenses, sold for the ClarityChrom or ClarityChromPrep. For an upgrade from ClarityChrom to ClarityChromPrep 7.2, please order article A1689-11. In your order always include your dongle serial number.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>System architecture</th>
<td>32-bit CDS</td>
</tr>
<tr>
<th>Operating system</th>
<td>Windows 10, Windows 7, Windows 8/8.1, Windows Vista SP2, all 32- and 64-bit; Windows XP SP3 (32-bit only)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychromorclaritychromprep72upgrade/">ClarityChrom or ClarityChromPrep 7.2 Upgrade</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2 option</title>
		<link>https://www.iconsci.com/shop/claritychrom72option/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 18:48:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72option/</guid>

					<description><![CDATA[<p>system suitability option</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72option/">ClarityChrom 7.2 option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>System suitability extension (SST)</p>
<p>The system suitability extension automates the calculation of system suitability parameters for system validation and calculates up to 12 parameters and compares the results with the limits the user has set.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>System suitability</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72option/">ClarityChrom 7.2 option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2 option</title>
		<link>https://www.iconsci.com/shop/claritychrom72option-a1676-11/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 18:47:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72option-a1676-11/</guid>

					<description><![CDATA[<p>option for PDA data processing</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72option-a1676-11/">ClarityChrom 7.2 option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>License option for PDA data processing</p>
<p>The PDA option allows to acquire and process spectra (3D data) from a photo diode array detector. KNAUER PDA detectors are fully supported. The PDA extension provides peak purity analysis and peak identification by spectral library search in self-made or commercial spectra libraries. Note, that for a separate Offline license (A1676-11 for ClarityChrom or A1688-11 for ClarityChromPrep) the PDA extension must be ordered additionally.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>PDA / 3D UV</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72option-a1676-11/">ClarityChrom 7.2 option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2 option</title>
		<link>https://www.iconsci.com/shop/claritychrom72option-a1679-11/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 18:44:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72option-a1679-11/</guid>

					<description><![CDATA[<p>option for LC-MS data processing</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72option-a1679-11/">ClarityChrom 7.2 option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Option for LC-MS data processing</p>
<p>The MS option allows to acquire and process data for LC-MS systems from a supported QUAD mass spectrometer. Please ask for a license, if a supported Triple-QUAD or TOF MS should be controlled; the currently selected license only supports QUAD-MS.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>Mass spectrometry</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72option-a1679-11/">ClarityChrom 7.2 option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2 option</title>
		<link>https://www.iconsci.com/shop/claritychrom72option-a1678-11/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 18:41:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72option-a1678-11/</guid>

					<description><![CDATA[<p>option for GPC data processing</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72option-a1678-11/">ClarityChrom 7.2 option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Option for GPC data processing</p>
<p>The SEC/GPC option provides interactive and automated gel permeation chromatography analysis, including re-calibration and GPC reporting, as well as simplifies the retrieval of GPC data. The GPC extension allows flow rate and multi-detector delay corrections and includes Narrow, Broad and Broad on Narrow calibrations.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>SEC/GPC</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72option-a1678-11/">ClarityChrom 7.2 option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2 option</title>
		<link>https://www.iconsci.com/shop/claritychrom72option-a1680-11/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 18:37:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72option-a1680-11/</guid>

					<description><![CDATA[<p>GC license for GC control</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72option-a1680-11/">ClarityChrom 7.2 option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>License for GC control</p>
<p>The license extension for GC control allows for the control of supported GC systems.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72option-a1680-11/">ClarityChrom 7.2 option</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2 Extension</title>
		<link>https://www.iconsci.com/shop/claritychrom72extension-a1674-11/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 18:32:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72extension-a1674-11/</guid>

					<description><![CDATA[<p>offline license for data evaluation</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72extension-a1674-11/">ClarityChrom 7.2 Extension</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Offline license for data evaluation</p>
<p>ClarityChrom Offline license for data evaluation for a separate computer. Additional extensions, as PDA, must be ordered separately. This Offline license only works with ClarityChrom; for ClarityChromPrep a separate offline license is available.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72extension-a1674-11/">ClarityChrom 7.2 Extension</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2 Extension</title>
		<link>https://www.iconsci.com/shop/claritychrom72extension-a1671-11/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 18:28:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72extension-a1671-11/</guid>

					<description><![CDATA[<p>Additional instrument license one additional time base</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72extension-a1671-11/">ClarityChrom 7.2 Extension</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Additional instrument license for one additional time base/system</p>
<p>Additional instrument license for a workstation license; adds one additional time base/system. Already existing extensions, as PDA, must not be added again to be available for the additional system.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72extension-a1671-11/">ClarityChrom 7.2 Extension</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2</title>
		<link>https://www.iconsci.com/shop/claritychrom72-a1670-11/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 22 Feb 2018 15:57:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72-a1670-11/</guid>

					<description><![CDATA[<p>single instrument license one time base</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72-a1670-11/">ClarityChrom 7.2</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Single instrument license, one time base</p>
<p>KNAUER ClarityChrom® is a powerful, yet easy-to-use chromatography software (or chromatography data system, CDS) for instrument control, data acquisition and data processing. ClarityChrom is designed for smaller laboratories. It is an economical solution compared to other more complex chromatography software while still offering FDA 21 CFR Part 11 compliance.</p>
<p>ClarityChrom comes as a complete package with LC control and including autosampler control. It is scalable from 1 up to 4 systems; depending on the desired instruments. The built-in fractionation option as well as the optional extensions as SST for automated system tests, PDA for 3D (UV spectra) data handling, GPC analysis, MS and GC control cover a wide range of the requirements for a CDS on a modern lab. KNAUER additionally offers are more advanced fractionation with the ClarityChromPrep software, which includes the complete functionality of the ClarityChrom.</p>
<p>ClarityChrom supports all KNAUER devices that can be controlled by software. Please refer to the instrument support list in the Support section of our website, the download link can be found below. Beside this, devices and systems from more than 45 manufacturers can be controlled. Additionally, data acquisition can also be performed with any detector providing a voltage output by simply connecting a KNAUER IFU 2.1 interface box or any other supported A/D converter.</p>
<p>The system suitability (SST) option automates the calculation of system suitability parameters for system validation and calculates up to 12 parameters and compares the results with the limits the user has set.</p>
<p>The PDA option allows to acquire and process 3D data from a photo diode array detector (KNAUER PDA detectors are fully supported). The PDA extension provides peak purity analysis and peak identification by spectral library search in self-made or commercial spectra libraries.</p>
<p>The SEC/GPC option provides interactive and automated gel permeation chromatography analysis, including re-calibration and GPC reporting, as well as simplifies the retrieval of GPC data. The GPC extension allows flow rate and multi-detector delay corrections and includes Narrow, Broad and Broad on Narrow calibrations.</p>
<p>ClarityChrom offers all the necessary operations for an analytical lab. Moreover, the preparative version adds fractionation options to this feature list and allows more flexibility in the lab. ClarityChrom is the best solution for all laboratories searching for an up-to-date and robust software with support of devices from many manufacturers to be flexible in instrumentation but also meet the requirements for modern laboratories.</p>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC</td>
</tr>
<tr>
<th>System architecture</th>
<td>32-bit CDS</td>
</tr>
<tr>
<th>Operating system</th>
<td>Windows 10, Windows 7, Windows 8/8.1, Windows Vista SP2, all 32- and 64-bit; Windows XP SP3 (32-bit only)</td>
</tr>
</tbody>
</table>
<h2 class="table-module__header">Expandability</h2>
<table class="table">
<tbody>
<tr>
<th>Stand-alone</th>
<td>Workstation version, max. 4 systems controlled by one computer, max. 3 complete systems, max. 2 systems with PDA detector</td>
</tr>
<tr>
<th>Client/server</th>
<td>No Client/Server functionality</td>
</tr>
<tr>
<th>Multi-user environment</th>
<td>Selectable system of user accounts with independently customizable behavior and appearance for individual users</td>
</tr>
<tr>
<th>Network environment</th>
<td>Easy offline data sharing (at the file level) among all stations in a local network</td>
</tr>
<tr>
<th>Fields of application</th>
<td>Analytical HPLC, GPC/SEC, GC, MS</td>
</tr>
<tr>
<th>Supported instruments</th>
<td>All KNAUER devices are supported, driver for devices from many other manufacturers are available</td>
</tr>
<tr>
<th>Instrument connection</th>
<td>Supports RS-232, Ethernet, PCI interface card, A/D-D/A interface</td>
</tr>
<tr>
<th>Recommended PC hardware</th>
<td>Pentium 2 GHz, 2 GB RAM, 10 GB free hard disk space, separate graphics card if one PC should control more than one system; 4 GB RAM recommended for PDA detectors</td>
</tr>
<tr>
<th>Graphics capabilities</th>
<td>Multiple chromatogram view and overlay, PDA view</td>
</tr>
<tr>
<th>Integration</th>
<td>27 integration parameters (peak width, threshold, tangent slope ratio etc.) integration parameters programmable in time, automatic re-integration</td>
</tr>
<tr>
<th>Calculation types</th>
<td>with/without calibration (int./ext. standard method)</td>
</tr>
<tr>
<th>Security and GLP</th>
<td>Installation qualification test of the software; FDA 21 CFR Part 11 conformance, validation with virtual detector</td>
</tr>
<tr>
<th>Instrument control</th>
<td>method-based instrument control, Instrument status display and Direct-Control mode, </td>
</tr>
<tr>
<th>Calibration</th>
<td>6 types of calibration curves, up to 20 levels, reference peaks, groups, unlimited number of standards (peaks), LOD, LOQ</td>
</tr>
<tr>
<th>Chromatogram operations</th>
<td>Overlay view, custom labels and settings, also applying mathematical operations to chromatograms</td>
</tr>
<tr>
<th>Automation</th>
<td>Sequences, automatic launch of selected commands or applications immediately following chromatogram acquisition – Post run, Batch</td>
</tr>
<tr>
<th>Presentation of results</th>
<td>Integrated customizable table of results, columns with userdefined calculation, summary table, and export in text or database format</td>
</tr>
<tr>
<th>Calculations</th>
<td>Custom: 12 predefined mathematical operators, 15 basic and 4 summary functions, special: Kovats indexes for GC, determination of noise/drift, performance calculations</td>
</tr>
<tr>
<th>Data import and export</th>
<td>ASCII, AIA, dBase</td>
</tr>
</tbody>
</table>
<h2 class="table-module__header">Additional options/extensions</h2>
<table class="table">
<tbody>
<tr>
<th>PDA option</th>
<td>separate license option; 3D chromatogram, peak purity analysis, spectrum search in self-made or commercial spectra library</td>
</tr>
<tr>
<th>GPC/SEC option</th>
<td>separate license option; molecular weight determination in size exclusion chromatography with various calibration methods</td>
</tr>
<tr>
<th>System suitability test</th>
<td>separate license option; automates the calculation of system suitability parameters for system validation</td>
</tr>
<tr>
<th>Note</th>
<td>Autosampler control included</td>
</tr>
</tbody>
</table>
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v1670-11_claritychrom_benutzerhandbuch_de_v6.0.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/v1670-11_claritychrom_benutzerhandbuch_de_v6.0.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">ClarityChrom 7.2.0 Software Handbuch DE (V1670-11)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">6.1 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/v1670-11_claritychrom_benutzerhandbuch_de_v6.0.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">ClarityChrom 7.2.0 Software Manual EN (V1670-11A)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">7.3 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72-a1670-11/">ClarityChrom 7.2</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ClarityChrom 7.2</title>
		<link>https://www.iconsci.com/shop/claritychrom72-a1672-11/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 22 Feb 2018 15:46:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/claritychrom72-a1672-11/</guid>

					<description><![CDATA[<p>Educational System license</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72-a1672-11/">ClarityChrom 7.2</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Educational System license for one system</p>
<p>ClarityChrom is an easy-to-use Chromatography Data System for workstations. The Educational System license is exclusively bundeled with the AZURA Educational System and features:</p>
<ul>
<li>a single instrument license,</li>
<li>an HPLC control module (no autosampler control), and</li>
<li>two offline licenses to evaluate data on two additional PCs.</li>
</ul>
<h1 class="headline">Technical Data</h1>
<div class="dinfo">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Software name</th>
<td>ClarityChrom</td>
</tr>
<tr>
<th>Extensions / Licenses</th>
<td>Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC</td>
</tr>
<tr>
<th>System architecture</th>
<td>32-bit CDS</td>
</tr>
<tr>
<th>Operating system</th>
<td>Windows 10, Windows 7, Windows 8/8.1, Windows Vista SP2, all 32- and 64-bit; Windows XP SP3 (32-bit only)</td>
</tr>
</tbody>
</table>
<h2 class="table-module__header">Expandability</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Stand-alone</th>
<td>Workstation version, max. 4 systems controlled by one computer, max. 3 complete systems recommended</td>
</tr>
<tr>
<th>Client/server</th>
<td>No Client/Server functionality</td>
</tr>
<tr>
<th>Multi-user environment</th>
<td>Selectable system of user accounts with independently customizable behavior and appearance for individual users</td>
</tr>
<tr>
<th>Network environment</th>
<td>Easy offline data sharing (at the file level) among all stations in a local network</td>
</tr>
<tr>
<th>Fields of application</th>
<td>Analytical HPLC</td>
</tr>
<tr>
<th>Supported instruments</th>
<td>All Knauer devices except autosamplers are supported, driver for devices from many other manufacturers are available</td>
</tr>
<tr>
<th>Instrument connection</th>
<td>Supports RS-232, Ethernet, PCI interface card, A/D-D/A interface</td>
</tr>
<tr>
<th>Recommended PC hardware</th>
<td>Pentium 2 GHz, 2 GB RAM, 10 GB free hard disk space, separate graphics card if one PC should control more than one system</td>
</tr>
<tr>
<th>Graphics capabilities</th>
<td>Multiple chromatogramm view and overlay</td>
</tr>
<tr>
<th>Integration</th>
<td>27 integration parameters (peak width, threshold, tangent slope ratio etc.) integration parameters programmable in time, automatic re-integration</td>
</tr>
<tr>
<th>Calculation types</th>
<td>with/without calibration (int./ext. standard method)</td>
</tr>
<tr>
<th>Security and GLP</th>
<td>Installation qualification test of the software; FDA 21 CFR Part 11 conformance, validation with virtual detector</td>
</tr>
<tr>
<th>Instrument control</th>
<td>method-based instrument control, Instrument status display and Direct-Control mode, </td>
</tr>
<tr>
<th>Calibration</th>
<td>6 types of calibration curves, up to 20 levels, reference peaks, groups, unlimited number of standards (peaks), LOD, LOQ</td>
</tr>
<tr>
<th>Chromatogram operations</th>
<td>Overlay view, custom labels and settings, also applying mathematical operations to chromatograms</td>
</tr>
<tr>
<th>Automation</th>
<td>Sequences, automatic launch of selected commands or applications immediately following chromatogram acquisition – Post run, Batch</td>
</tr>
<tr>
<th>Presentation of results</th>
<td>Integrated customizable table of results, columns with userdefined calculation, summary table, and export in text or database format</td>
</tr>
<tr>
<th>Calculations</th>
<td>Custom: 12 predefined mathematical operators, 15 basic and 4 summary functions, special: Kovats indexes for GC, determination of noise/drift, performance calculations</td>
</tr>
<tr>
<th>Data import and export</th>
<td>ASCII, AIA, dBase</td>
</tr>
</tbody>
</table>
<h2 class="table-module__header">Additional options/extensions</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>System suitability test</th>
<td>automates the calculation of system suitability parameters for system validation</td>
</tr>
<tr>
<th>Note</th>
<td>no autosampler control included</td>
</tr>
</tbody>
</table>
</div>
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v1670-11_claritychrom_benutzerhandbuch_de_v6.0.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/v1670-11_claritychrom_benutzerhandbuch_de_v6.0.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">ClarityChrom 7.2.0 Software Handbuch DE (V1670-11)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">6.1 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/v1670-11_claritychrom_benutzerhandbuch_de_v6.0.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">ClarityChrom 7.2.0 Software Manual EN (V1670-11A)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">7.3 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/v1670-11a_claritychrom_software_manual_v6.0.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/claritychrom72-a1672-11/">ClarityChrom 7.2</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
