<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Radioactivity detectors &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/radioactivity-detectors/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Wed, 28 Feb 2018 15:42:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>Radioactivity detectors &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Radioactivityflow detector Gabi*</title>
		<link>https://www.iconsci.com/shop/radioactivityflowdetectorgabi-a1645/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 28 Feb 2018 15:42:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/radioactivityflowdetectorgabi-a1645/</guid>

					<description><![CDATA[<p>detects radiolabelled compounds by HPLC</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/radioactivityflowdetectorgabi-a1645/">Radioactivityflow detector Gabi*</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>A novel design of the optics allows for multiple reflection through the flow cell (multi path), resulting in a greater layer thickness. As the optical rotation is proportional to layer thickness, the sensitivity is enhanced.The instrument works at the measurement wavelength optimum at 430 nm. ’’Zero drift’’ electronics ensure short warm-up delay and reproducible results. The chiralyser features touch screen operation with a clear menu structure. The optimization is easy and requires no special prerequisites.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Detection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Detector type</th>
<td>Radioactivity detector</td>
</tr>
<tr>
<th>Version</th>
<td>flow-through γ-radioactivity monitor</td>
</tr>
<tr>
<th>Detection channels</th>
<td>2</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Inputs</th>
<td>7 analog input channels, -0.5 to +4.5 V, resolution 21 bit</td>
</tr>
<tr>
<th>Outputs</th>
<td>RS232C, 2 analog outputs 0 to 1 V, resolution 20 bit</td>
</tr>
<tr>
<th>Control</th>
<td>keyboard 16 touch sensetive keys, digital communication to pc, Gina* programm</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>Temperature range: 10 &#8211; 40 °C Humidity: below 70 % noncondensing</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>230 V; 50 Hz</td>
</tr>
<tr>
<th>Dimensions</th>
<td>250 x 160 x 320 mm (W x H x D)</td>
</tr>
</tbody>
</table>
</div>
<div class="hzone">
<h2 class="table-module__header">Software</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Note</th>
<td>Scintillation probe has to be additionally choosen.</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/raytest_gabistar_manual_de_2003.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/raytest_gabistar_manual_de_2003.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Gabi Star Gamma Radioaktivitäts-Durchfluss-Monitor Benutzerhandbuch DE</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">439.8 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/raytest_gabistar_manual_de_2003.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/radioactivityflowdetectorgabi-a1645/">Radioactivityflow detector Gabi*</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>