<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Liquid Nanoparticles (LNP) &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/liquid-nanoparticles-lnp/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Fri, 09 Jul 2021 18:47:55 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>Liquid Nanoparticles (LNP) &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Customized Impingement jets mixing skids for Large Production Scale</title>
		<link>https://www.iconsci.com/shop/customized-impingement-jets-mixing-skids-for-large-production-scale/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Fri, 09 Jul 2021 18:42:56 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4721</guid>

					<description><![CDATA[<p>The Impingement Jets Mixing (IJM) Large Production Scale Units for high flow production of nanoparticles (LNP, microemulsions, etc.) can be [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/customized-impingement-jets-mixing-skids-for-large-production-scale/">Customized Impingement jets mixing skids for Large Production Scale</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Impingement Jets Mixing (IJM) Large Production Scale Units for high flow production of nanoparticles (LNP, microemulsions, etc.) can be configured with up to eight parallel mixing units depending on the customer requirements. Each unit consists of two pumps to deliver lipid and API streams, two flowmeters for flow control, and one jet mixer.</p>
<p>Depending on the configuration, the predilution of the API and quenching can be performed for the combined flow of all units in one process step outside the Impingement Jets Mixing (IJM) Production Scale Unit.</p>
<p>The number of parallel units depends on the application. Also, the number of pumps, flowmeters, jets mixers, and pipes can be adapted to the required conditions and scale. All skids are built in a stainless steel frame on casters and are suitable for CIP cleaning procedures in pharmaceutical production.</p>
<p>&nbsp;</p>
<p>The Impingement Jets Mixing (IJM) Large Production Scale Unit for high flow production of nanoparticles (LNP, microemulsions, etc.) consisting of:</p>
<ul>
<li>up to 16 KNAUER high-pressure dosing pumps 80P</li>
<li>up to 16 Coriolis flow meters</li>
<li>up to 8 KNAUER IJM mixers</li>
<li>Inlet manifolds for lipid/ethanol mixture and mRNA/buffer mixture</li>
<li>Outlet manifold for LNP solution</li>
<li>Back-seal washing system</li>
<li>The frame (stainless steel system 1.4301)</li>
<li>Installation &amp; familiarization by KNAUER</li>
</ul>
<p>&nbsp;</p>
<p>&nbsp;</p>
<h2 class="table-module__header">Impingement Jets Mixing Skids Details</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Number of impingement jets mixers</th>
<td>up to 8</td>
</tr>
<tr>
<th>Number of pumps</th>
<td>up to 16</td>
</tr>
<tr>
<th>Number of flow meter</th>
<td>up to 16</td>
</tr>
<tr>
<th>Process connection inlet</th>
<td>Sanitary Clamp Connector (2 Inlets)</td>
</tr>
<tr>
<th>Process connection outlet</th>
<td>Sanitary Clamp Connector (1 Outlet)</td>
</tr>
<tr>
<th>Volumetric flow rate (L/min)</th>
<td>depending on configuration</td>
</tr>
<tr>
<th>Volumetric flow rate (L/hour)</th>
<td>depending on configuration</td>
</tr>
<tr>
<th>Maximum operation pressure</th>
<td>50-70 bar</td>
</tr>
<tr>
<th>Liquid temperature range</th>
<td>4−60 °C (39.2−140 °F)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td><span title="Stainless steel is, apart from PEEK, the standard material in HPLC. Steels with WNr. 1.4404 (316L) are used, or with a mixture of higher compatibility.  They are inert against almost all solvents. Exceptions are biological applications which are metal ion sensible, and applications with extreme corrosive conditions. These steels, in comparison to commonly used steels, are increasingly resistant against hydrochloric acid, cyanides and other halogen acids, chlorides and chlorinated solvents. The use in ion cromatography is not recommended. In case of electrochemical applications, a passivation must be executed first.">stainless steel</span>, <span title="PEEK is a durable and resistant plastic and, apart from stainless steel, the standard material in HPLC. It can be used at temperatures up to 100 °C and is highly chemical resistant against almost all commonly used solvents in a pH range of 1-12, 5. PEEK is potentially moderate resistant against oxidizing and reducing solvents. Therefore, following solvents should not be used: Concentrated and oxidizing acids (such as nitric acid solution, sulfuric acid), halogenated acids (such as hydrofluoric acid, hydrobromic acid) and gaseous halogens. Hydrochloric acid is approved for most applications. In addition, following solvents can have a swelling effect and may have an impact on the functionality of the built-in components: Methylene chloride, THF and DMSO in any concentration such as acetonitrile in higher concentrations. ">PEEK</span>, <span title="Titanium has a low weight and a high hardness and stability. Is stands out due to its very high chemical compatibility and biocompatibility. Titan is applied when neither stainless steel nor PEEK are usable.">Titanium</span>, <span title="This perfluoro elastomer has a higher fluorine content as fluorinated rubber and is therefore chemically more resistant. It can be employed at higher temperatures (up to 275 °C). It is not compatible with Pyrrole.">FFKM</span>, <span title="PTFE is very soft and anti-adhesive. This material is resistant against almost all acids, lyes and solvents, except against fluid natrium and fluoride compounds. In addition, it is temperature-resistant from -200 °C to +260 °C.">PTFE</span>, GFP (graphite fiber reinforced PTFE), <span title="Due to their high resistance to wear and corrosion,  aluminium oxide ceramics are used as a coating for mechanically stressed surfaces. They are a biocompatible material with low thermal conductivity and low thermal expansion.">aluminum oxide (Al<sub>2</sub>O<sub>3</sub>)</span>, <span title="Synthetic ruby is monocrystalline aluminium oxide and has a red coloration by the addition of some chromium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Ruby is used as piston material in HPLC pumps.">ruby</span>, <span title="Synthetic sapphire is virtually pure monocrystalline aluminium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Sapphire is used as piston material in HPLC pumps.">sapphire</span></td>
</tr>
<tr>
<th>Software</th>
<td>not included, necessary interfaces for the integration into PLC available</td>
</tr>
<tr>
<th>Interfaces</th>
<td>Pump: LAN, RS-232, pin header connectors;<br />
Flow meter: RS-232 + Industrial Interfaces;<br />
Valve drive: LAN</td>
</tr>
<tr>
<th>Power supply</th>
<td>Pump: 100–240 V, 50–60 Hz;<br />
Flow meter: +15…24 V DC,</td>
</tr>
<tr>
<th>Maximum power consumption</th>
<td>Values per device<br />
Pump: maximum 320 W;<br />
Flow meter: 3 W</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>Temperature range: 4–40 °C; 39.2–104 °F; below 90 % humidity (non condensing)</td>
</tr>
<tr>
<th>Dimensions</th>
<td>depending on configuration</td>
</tr>
<tr>
<th>Weight</th>
<td>depending on configuration</td>
</tr>
<tr>
<th>API-predilution and quenching</th>
<td>depending on configuration</td>
</tr>
<tr>
<th>GMP-ready documentation</th>
<td>YES</td>
</tr>
<tr>
<th>Factory acceptance test</th>
<td>YES</td>
</tr>
<tr>
<th>Site acceptance test</th>
<td>YES</td>
</tr>
<tr>
<th>Purchase order lead time</th>
<td>minimum 5 months, depending on customer requirements</td>
</tr>
<tr>
<th>Disclaimer</th>
<td>Depending on the process the end user must consider the legal situation of patents and intellectual property. KNAUER is designing the customized hardware solution on customers request</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/customized-impingement-jets-mixing-skids-for-large-production-scale/">Customized Impingement jets mixing skids for Large Production Scale</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Impingement jets mixing skid for Pilot Scale</title>
		<link>https://www.iconsci.com/shop/impingement-jets-mixing-skid-for-pilot-scale/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Fri, 09 Jul 2021 18:39:49 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4719</guid>

					<description><![CDATA[<p>The Impingement Jets Mixing (IJM) Pilot Scale Unit for high-flow production of nanoparticles (LNP, microemulsions, etc.) is the perfect choice for [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/impingement-jets-mixing-skid-for-pilot-scale/">Impingement jets mixing skid for Pilot Scale</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Impingement Jets Mixing (IJM) Pilot Scale Unit for high-flow production of nanoparticles (LNP, microemulsions, etc.) is the perfect choice for R&amp;D purposes and small productions batches.</p>
<p>The unit contains of four pumps enabling all the steps from predilution of the Concentrated Active Pharmaceutical Ingredient (API), Impingement Jets Mixing of lipid and API phase and finally the quenching of the nanoparticle solution.</p>
<p>Furthermore the unit is equipped with four flowmeters for flow monitoring, one jets mixer and two mixers for predilution and quenching. Our CDS software provides an intuitive and easy operating of the IJM-SKID. The system visualization offers a graphical representation and allows easy handling of the complex flow processes. Additionaly, each device which is displayed in the fluidic scheme can be manually controlled, giving the opportunity to optimize, change and adapt your conditions also during the run. The software complies with 21 CFR Part 11.</p>
<p>The skid is built in a stainless steel frame on casters and are suitable for CIP cleaning procedure in pharmaceutical production.</p>
<p>&nbsp;</p>
<p>The Impingement Jets Mixing (IJM) Pilot Scale Unit for high flow production of nanoparticles (LNP, microemulsions, etc.) consisting of:</p>
<ul>
<li>4 KNAUER high-pressure dosing pumps 80P</li>
<li>4 Coriolis flow meters</li>
<li>1 KNAUER IJM mixers</li>
<li>2 Mixers</li>
<li>8-port multiposition Valve</li>
<li>Inlet for Lipid and mRNA (Sanitary Clamp Connector)</li>
<li>Inlet for buffer (Sanitary Clamp Connector)</li>
<li>Outlet for LNP solution (Sanitary Clamp Connector)</li>
<li>Internal piping</li>
<li>Frame (stainless steel system 1.4301)</li>
<li>CDS software, 21 CFR part 11 compliant</li>
<li>Chromatography workstation with 27&#8243; monitor</li>
<li>Installation &amp; familiarization by KNAUER</li>
</ul>
<p>&nbsp;</p>
<p>&nbsp;</p>
<h2 class="table-module__header">Impingement Jets Mixing Skids Details</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Number of impingement jets mixers</th>
<td>1</td>
</tr>
<tr>
<th>Number of pumps</th>
<td>4</td>
</tr>
<tr>
<th>Number of flow meter</th>
<td>4</td>
</tr>
<tr>
<th>Number of valves</th>
<td>1</td>
</tr>
<tr>
<th>Process connection inlet</th>
<td>1/2&#8243; Tri-clamp (4 Inlets) &#8211; different connections on request</td>
</tr>
<tr>
<th>Process connection outlet</th>
<td>1/2“ Tri-clamp (1 Outlet) &#8211; different connections on request.</td>
</tr>
<tr>
<th>Volumetric flow rate (L/min)</th>
<td>up to 1 liter/min</td>
</tr>
<tr>
<th>Volumetric flow rate (L/hour)</th>
<td>up to 60 liter/h</td>
</tr>
<tr>
<th>Maximum operation pressure</th>
<td>100 bar</td>
</tr>
<tr>
<th>Liquid temperature range</th>
<td>4−60 °C (39.2−140 °F)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td><span title="Stainless steel is, apart from PEEK, the standard material in HPLC. Steels with WNr. 1.4404 (316L) are used, or with a mixture of higher compatibility.  They are inert against almost all solvents. Exceptions are biological applications which are metal ion sensible, and applications with extreme corrosive conditions. These steels, in comparison to commonly used steels, are increasingly resistant against hydrochloric acid, cyanides and other halogen acids, chlorides and chlorinated solvents. The use in ion cromatography is not recommended. In case of electrochemical applications, a passivation must be executed first.">stainless steel</span>, <span title="PEEK is a durable and resistant plastic and, apart from stainless steel, the standard material in HPLC. It can be used at temperatures up to 100 °C and is highly chemical resistant against almost all commonly used solvents in a pH range of 1-12, 5. PEEK is potentially moderate resistant against oxidizing and reducing solvents. Therefore, following solvents should not be used: Concentrated and oxidizing acids (such as nitric acid solution, sulfuric acid), halogenated acids (such as hydrofluoric acid, hydrobromic acid) and gaseous halogens. Hydrochloric acid is approved for most applications. In addition, following solvents can have a swelling effect and may have an impact on the functionality of the built-in components: Methylene chloride, THF and DMSO in any concentration such as acetonitrile in higher concentrations. ">PEEK</span>, <span title="Titanium has a low weight and a high hardness and stability. Is stands out due to its very high chemical compatibility and biocompatibility. Titan is applied when neither stainless steel nor PEEK are usable.">Titanium</span>, <span title="This perfluoro elastomer has a higher fluorine content as fluorinated rubber and is therefore chemically more resistant. It can be employed at higher temperatures (up to 275 °C). It is not compatible with Pyrrole.">FFKM</span>, <span title="PTFE is very soft and anti-adhesive. This material is resistant against almost all acids, lyes and solvents, except against fluid natrium and fluoride compounds. In addition, it is temperature-resistant from -200 °C to +260 °C.">PTFE</span>, GFP (graphite fiber reinforced PTFE), <span title="Due to their high resistance to wear and corrosion,  aluminium oxide ceramics are used as a coating for mechanically stressed surfaces. They are a biocompatible material with low thermal conductivity and low thermal expansion.">aluminum oxide (Al<sub>2</sub>O<sub>3</sub>)</span>, <span title="Synthetic ruby is monocrystalline aluminium oxide and has a red coloration by the addition of some chromium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Ruby is used as piston material in HPLC pumps.">ruby</span>, <span title="Synthetic sapphire is virtually pure monocrystalline aluminium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Sapphire is used as piston material in HPLC pumps.">sapphire</span></td>
</tr>
<tr>
<th>Software</th>
<td>CDS, 21 CFR part 11 compliant</td>
</tr>
<tr>
<th>Interfaces</th>
<td>Pump: LAN, RS-232, pin header connectors;<br />
Flow meter: RS-232 + FLOWBUS;<br />
Valve drive: LAN</td>
</tr>
<tr>
<th>Power supply</th>
<td>Pump: 100–240 V, 50–60 Hz;<br />
Flow meter: +15…24 V DC,<br />
Valve drive: 24 V DC</td>
</tr>
<tr>
<th>Maximum power consumption</th>
<td>Values per device<br />
Pump: maximum 320 W;<br />
Flow meter: 3 W ;<br />
Valve drive: 65 W</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>Temperature range: 4–40 °C; 39.2–104 °F; below 90 % humidity (non condensing)</td>
</tr>
<tr>
<th>Dimensions</th>
<td>900 x 915 x 700 mm</td>
</tr>
<tr>
<th>Weight</th>
<td>~ 150 kg</td>
</tr>
<tr>
<th>API-predilution and quenching</th>
<td>YES</td>
</tr>
<tr>
<th>GMP-ready documentation</th>
<td>YES</td>
</tr>
<tr>
<th>Factory acceptance test</th>
<td>YES</td>
</tr>
<tr>
<th>Site acceptance test</th>
<td>YES</td>
</tr>
<tr>
<th>Purchase order lead time</th>
<td>about 3 months</td>
</tr>
<tr>
<th>Disclaimer</th>
<td>Depending on the process the end user must consider the legal situation of patents and intellectual property. KNAUER is designing the customized hardware solution on customers request</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/impingement-jets-mixing-skid-for-pilot-scale/">Impingement jets mixing skid for Pilot Scale</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Impingement jets mixing skid for Small Production Scale</title>
		<link>https://www.iconsci.com/shop/impingement-jets-mixing-skid-for-small-production-scale/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Fri, 09 Jul 2021 18:37:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4718</guid>

					<description><![CDATA[<p>The Impingement Jets Mixing (IJM) Small Production Scale Unit for high flow production of nanoparticles (LNP, microemulsions, etc.) contains two parallel [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/impingement-jets-mixing-skid-for-small-production-scale/">Impingement jets mixing skid for Small Production Scale</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Impingement Jets Mixing (IJM) Small Production Scale Unit for high flow production of nanoparticles (LNP, microemulsions, etc.) contains two parallel mixing units. Each unit consists of four pumps enabling all the steps from predilution of the Concentrated Active Pharmaceutical Ingredient (API), Impingement Jets Mixing of lipid and API phase, and finally the quenching of the nanoparticle solution. Furthermore, each unit is equipped with four flowmeters for flow monitoring, one jets mixer, and two mixers for predilution and quenching.</p>
<p>&nbsp;</p>
<p>Knauer&#8217;s CDS software provides an intuitive and easy operating of the IJM-SKID. The system visualization offers a graphical representation and allows easy handling of the complex flow processes. Additionally, each device that is displayed in the fluidic scheme can be manually controlled. You have the opportunity to optimize, change and adapt your conditions also during the run. The software complies with 21 CFR Part 11.</p>
<p>All skids are built in a stainless steel frame on casters and are suitable for CIP cleaning procedures in pharmaceutical production.</p>
<p>&nbsp;</p>
<p>The Impingement Jets Mixing (IJM) Small Production Scale Unit for high flow production of nanoparticles (LNP, microemulsions, etc.) consisting of:</p>
<ul>
<li>8 KNAUER high-pressure dosing pumps 80P</li>
<li>8 Coriolis flow meters</li>
<li>2 Impingement jet mixers</li>
<li>4 Mixers</li>
<li>2 8-port multiposition Valve</li>
<li>Inlet for Lipid and mRNA (Sanitary Clamp Connector)</li>
<li>Inlet for citrate buffer (Sanitary Clamp Connector)</li>
<li>An outlet for LNP solution (Sanitary Clamp Connector)</li>
<li>Internal piping</li>
<li>Frame (Stainless Steel system 1.4301; 1000 x 1310 x 800 mm (WxHxD))</li>
<li>CDS software, 21 CFR part 11 compliant</li>
<li>Chromatography workstation with 27&#8243; monitor</li>
</ul>
<p>&nbsp;</p>
<h2 class="table-module__header">Impingement Jets Mixing Skids Details</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Number of impingement jets mixers</th>
<td>4</td>
</tr>
<tr>
<th>Number of pumps</th>
<td>8</td>
</tr>
<tr>
<th>Number of flow meter</th>
<td>8</td>
</tr>
<tr>
<th>Number of valves</th>
<td>2</td>
</tr>
<tr>
<th>Process connection inlet</th>
<td>3/8&#8243; and 1/4&#8243; barbed fitting (6 Inlets) &#8211; different connections on request</td>
</tr>
<tr>
<th>Process connection outlet</th>
<td>1/4&#8243; barbed fitting (2 Outlets) &#8211; different connections on request.</td>
</tr>
<tr>
<th>Volumetric flow rate (L/min)</th>
<td>up to 2 liter/min</td>
</tr>
<tr>
<th>Volumetric flow rate (L/hour)</th>
<td>up to 120 liter/h</td>
</tr>
<tr>
<th>Maximum operation pressure</th>
<td>100 bar</td>
</tr>
<tr>
<th>Liquid temperature range</th>
<td>4−60 °C (39.2−140 °F)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td><span title="Stainless steel is, apart from PEEK, the standard material in HPLC. Steels with WNr. 1.4404 (316L) are used, or with a mixture of higher compatibility.  They are inert against almost all solvents. Exceptions are biological applications which are metal ion sensible, and applications with extreme corrosive conditions. These steels, in comparison to commonly used steels, are increasingly resistant against hydrochloric acid, cyanides and other halogen acids, chlorides and chlorinated solvents. The use in ion cromatography is not recommended. In case of electrochemical applications, a passivation must be executed first.">stainless steel</span>, <span title="PEEK is a durable and resistant plastic and, apart from stainless steel, the standard material in HPLC. It can be used at temperatures up to 100 °C and is highly chemical resistant against almost all commonly used solvents in a pH range of 1-12, 5. PEEK is potentially moderate resistant against oxidizing and reducing solvents. Therefore, following solvents should not be used: Concentrated and oxidizing acids (such as nitric acid solution, sulfuric acid), halogenated acids (such as hydrofluoric acid, hydrobromic acid) and gaseous halogens. Hydrochloric acid is approved for most applications. In addition, following solvents can have a swelling effect and may have an impact on the functionality of the built-in components: Methylene chloride, THF and DMSO in any concentration such as acetonitrile in higher concentrations. ">PEEK</span>, <span title="Titanium has a low weight and a high hardness and stability. Is stands out due to its very high chemical compatibility and biocompatibility. Titan is applied when neither stainless steel nor PEEK are usable.">Titanium</span>, <span title="This perfluoro elastomer has a higher fluorine content as fluorinated rubber and is therefore chemically more resistant. It can be employed at higher temperatures (up to 275 °C). It is not compatible with Pyrrole.">FFKM</span>, <span title="PTFE is very soft and anti-adhesive. This material is resistant against almost all acids, lyes and solvents, except against fluid natrium and fluoride compounds. In addition, it is temperature-resistant from -200 °C to +260 °C.">PTFE</span>, GFP (graphite fiber reinforced PTFE), <span title="Due to their high resistance to wear and corrosion,  aluminium oxide ceramics are used as a coating for mechanically stressed surfaces. They are a biocompatible material with low thermal conductivity and low thermal expansion.">aluminum oxide (Al<sub>2</sub>O<sub>3</sub>)</span>, <span title="Synthetic ruby is monocrystalline aluminium oxide and has a red coloration by the addition of some chromium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Ruby is used as piston material in HPLC pumps.">ruby</span>, <span title="Synthetic sapphire is virtually pure monocrystalline aluminium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Sapphire is used as piston material in HPLC pumps.">sapphire</span></td>
</tr>
<tr>
<th>Software</th>
<td>CDS, 21 CFR part 11 compliant</td>
</tr>
<tr>
<th>Interfaces</th>
<td>Pump: LAN, RS-232, pin header connectors;<br />
Flow meter: RS-232 + FLOWBUS;<br />
Valve drive: LAN</td>
</tr>
<tr>
<th>Power supply</th>
<td>Pump: 100–240 V, 50–60 Hz;<br />
Flow meter: +15…24 V DC,<br />
Valve drive: 24 V DC</td>
</tr>
<tr>
<th>Maximum power consumption</th>
<td>Values per device<br />
Pump: maximum 320 W;<br />
Flow meter: 3 W ;<br />
Valve drive: 65 W</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>Temperature range: 4–40 °C; 39.2–104 °F; below 90 % humidity (non condensing)</td>
</tr>
<tr>
<th>Dimensions</th>
<td>1000 x 1290 x 700 mm</td>
</tr>
<tr>
<th>Weight</th>
<td>~ 250kg</td>
</tr>
<tr>
<th>API-predilution and quenching</th>
<td>YES</td>
</tr>
<tr>
<th>GMP-ready documentation</th>
<td>YES</td>
</tr>
<tr>
<th>Factory acceptance test</th>
<td>YES</td>
</tr>
<tr>
<th>Site acceptance test</th>
<td>YES</td>
</tr>
<tr>
<th>Purchase order lead time</th>
<td>about 3 months</td>
</tr>
<tr>
<th>Disclaimer</th>
<td>Depending on the process the end user must consider the legal situation of patents and intellectual property. KNAUER is designing the customized hardware solution on customers request</td>
</tr>