<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Lamps &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/lamps/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Wed, 12 Mar 2025 14:28:11 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>Lamps &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ANSER Series- Motorized Valve</title>
		<link>https://www.iconsci.com/shop/anser-series-motorized-valve-7/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 12 Mar 2025 14:28:11 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4915</guid>

					<description><![CDATA[<p>Motorized multi purpose valve. It can be used as a single column valve with reverse flow and bypass or mixer [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-series-motorized-valve-7/">ANSER Series- Motorized Valve</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Motorized multi purpose valve. It can be used as a single column valve with reverse flow and bypass or mixer bypass or for multi step purification for 10 and 50ml/ min. pumping systems.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-series-motorized-valve-7/">ANSER Series- Motorized Valve</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PMP-30xx</title>
		<link>https://www.iconsci.com/shop/pmp-30xx/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Fri, 18 Aug 2023 16:27:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4866</guid>

					<description><![CDATA[<p>      PMP-3010 (analytical)  PMP-3050 (semi-preparative)  PMP-3150 (preparative)    ANSER Double Piston Parallel Pump      Specifications List    [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/pmp-30xx/">PMP-30xx</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span data-ccp-props="{}"> </span></p>
<p><span data-ccp-props="{}"> </span></p>
<p><span data-ccp-props="{&quot;335559739&quot;:24}"> </span></p>
<p><b><span data-contrast="auto">PMP-3010 (analytical)</span></b><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:24,&quot;335559740&quot;:276}"> </span></p>
<p><b><span data-contrast="auto">PMP-3050 (semi-preparative)</span></b><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:24,&quot;335559740&quot;:276}"> </span></p>
<p><b><span data-contrast="auto">PMP-3150 (preparative)</span></b><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:24,&quot;335559740&quot;:276}"> </span></p>
<p><span data-ccp-props="{&quot;335559739&quot;:24}"> </span></p>
<p><b><span data-contrast="auto">ANSER Double Piston Parallel Pump</span></b><span data-ccp-props="{&quot;335559739&quot;:24}"> </span></p>
<p><span data-ccp-props="{&quot;335559739&quot;:24}"> </span></p>
<p><span data-ccp-props="{&quot;335559739&quot;:24}"> </span></p>
<p><b><span data-contrast="auto">Specifications List</span></b><span data-ccp-props="{&quot;335559739&quot;:24}"> </span></p>
<p><span data-ccp-props="{}"> </span></p>
<p><span data-ccp-props="{}"> </span></p>
<table data-tablestyle="MsoNormalTable" data-tablelook="1184" aria-rowcount="19">
<tbody>
<tr aria-rowindex="1">
<td data-celllook="4369"><b><span data-contrast="auto">Model</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><b><span data-contrast="auto">PMP-3010, -3050, -3150 </span></b><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></td>
</tr>
<tr aria-rowindex="2">
<td data-celllook="4369"><b><span data-contrast="auto">Flow Delivery System</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">Double-piston parallel pump with independently driven pistons</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="3">
<td data-celllook="4369"><b><span data-contrast="auto">Piston backflushing</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">Passive or active with additional pump </span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="4">
<td data-celllook="4369"><b><span data-contrast="auto">Flow rate range</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">0.002 &#8211; 10.0</span> <span data-contrast="auto">ml/min in 0.001 ml/min increments (PMP-3010)</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">0.005 &#8211; 50.0</span> <span data-contrast="auto">ml/min in 0.001 ml/min increments (PMP-3050)</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">0.02 &#8211; 150.0</span> <span data-contrast="auto">ml/min in 0.001 ml/min increments (PMP-3150)</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="5">
<td data-celllook="4369"><b><span data-contrast="auto">Flow rate precision</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">&lt; 0.07 % (RSD), 1 ml/min of methanol/water (8:2) at 200 bar (PMP-3010)</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">&lt; 0.15 % (RSD), 5 ml/min of methanol/water (8:2) at 100 bar (PMP-3050)</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">&lt; 0.5 % (RSD), 25 ml/min of methanol/water (8:2) at 25 bar (PMP-3150)</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="6">
<td data-celllook="4369"><b><span data-contrast="auto">Flow rate accuracy</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">&lt; 1 % or 10 µl/min, whatever is greater (PMP-3010)</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">&lt; 1 % or 50 µl/min, whatever is greater (PMP-3050)</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">&lt; 1 % or 100 µl/min, whatever is greater (PMP-3150)</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="7">
<td data-celllook="4369"><b><span data-contrast="auto">Pressure pulsation</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">&lt; 1 % or &lt;0.2 MPa (2 bar), whatever is greater (PMP-3010)</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">&lt; 1.5 % or &lt;0.3 MPa (3 bar), whatever is greater (PMP-3050)</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">&lt; 5 % or &lt;0.5 MPa (5 bar), whatever is greater (PMP-3150)</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="8">
<td data-celllook="4369"><b><span data-contrast="auto">Maximum operating pressure</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">60 MPa / 600 bar / 8700 psi (PMP-3010)</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">25 MPa / 250 bar / 3750 psi (PMP-3050)</span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">10 MPa / 100 bar / 1450 psi (PMP-3150)</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="9">
<td data-celllook="4369"><b><span data-contrast="auto">System protection</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">Soft start, programmable minimum and maximum pressure limits, optional leakage sensor, external error input</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="10">
<td data-celllook="4369"><b><span data-contrast="auto">Optional components</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">Valves block for binary and quaternary low-pressure gradient</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">Pump for active piston-backflushing</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">Leakage sensor</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></td>
</tr>
<tr aria-rowindex="11">
<td data-celllook="4369"><b><span data-contrast="auto">Wetted materials</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">Titanium (capillaries, pump heads)</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">Ceramic (pressure transducer)</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">PTFE, PEEK (seals, draw-off valve)</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">Sapphire (plungers)</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">Ruby, ceramic (check valves)</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">Pump heat materials (stainless steel, Hastelloy C, ceramic, PEEK)</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></td>
</tr>
<tr aria-rowindex="12">
<td data-celllook="4369"><b><span data-contrast="auto">Stand-alone operation</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">4” LCD with touch panel</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="13">
<td data-celllook="4369"><b><span data-contrast="auto">Remote operation</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">Start/Stop input</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">Error output</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">Flow rate control input 0&#8230;10 V</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">Pressure signal analogue output 0..+2,5 V</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></td>
</tr>
<tr aria-rowindex="14">
<td data-celllook="4369"><b><span data-contrast="auto">Communication</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">LAN 10/100 Mbit/s</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></p>
<p><span data-contrast="auto">USB 2.0</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559740&quot;:360}"> </span></td>
</tr>
<tr aria-rowindex="15">
<td data-celllook="4369"><b><span data-contrast="auto">Power requirements</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">External power supply, 24 Vdc, 5 A max.</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="16">
<td data-celllook="4369"><b><span data-contrast="auto">Operating temperature</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">4 &#8211; 45 °C / 41 &#8211; 95 °F</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="17">
<td data-celllook="4369"><b><span data-contrast="auto">Humidity</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">0 &#8211; 90 %, non-condensing</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="18">
<td data-celllook="4369"><b><span data-contrast="auto">Weight without power supply</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="auto">4.5 kg / 9.9 lbs without external power supply</span><span data-ccp-props="{}"> </span></td>
</tr>
<tr aria-rowindex="19">
<td data-celllook="4369"><b><span data-contrast="auto">Size</span></b><span data-ccp-props="{}"> </span></td>
<td data-celllook="4369"><span data-contrast="none">130 x 200 x 320 mm / 5.0 x 5.1 x 13.7 in. (W x H x D)</span><span data-ccp-props="{}"> </span></td>
</tr>
</tbody>
</table>
<p><span data-contrast="auto"> </span><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">Specifications are subject to change without notice</span><span data-ccp-props="{}"> </span></p>
<p><span data-ccp-props="{&quot;134245418&quot;:true}"> </span></p>
<p><span data-ccp-props="{}"> </span></p>
<p><span data-ccp-props="{}"> </span></p>
<p><span data-ccp-props="{}"> </span></p>
<p><span data-ccp-props="{}"> </span></p>
<p><span data-ccp-props="{}"> </span></p>
<p><b><span data-contrast="none">Icon Scientific Inc.</span></b><span data-ccp-props="{}"> </span></p>
<p><span data-ccp-props="{}"> </span></p>
<p><b><span data-contrast="none">Visit our website:  </span></b><a href="http://www.iconsci.com/"><span data-contrast="none">www.iconsci.com</span></a><span data-ccp-props="{}"> </span></p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/pmp-30xx/">PMP-30xx</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ANSER PMP-3010 Double Piston Parallel Pump</title>
		<link>https://www.iconsci.com/shop/anser-pmp-3010-double-piston-parallel-pump/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Wed, 26 Apr 2023 14:02:18 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4851</guid>

					<description><![CDATA[<p>ANSER PMP-3010 Double Piston Parallel Pump   Specifications List         Model PMP-3010 Flow Delivery System Double-piston parallel [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-pmp-3010-double-piston-parallel-pump/">ANSER PMP-3010 Double Piston Parallel Pump</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>ANSER PMP-3010 Double Piston Parallel Pump</p>
<p><strong> </strong></p>
<p><strong>Specifications List</strong></p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<table>
<tbody>
<tr>
<td width="151"><strong>Model</strong></td>
<td width="305"><strong>PMP-</strong><strong>3010</strong></td>
</tr>
<tr>
<td width="151"><strong>Flow Delivery System</strong></td>
<td width="305">Double-piston parallel pump with independently driven pistons</td>
</tr>
<tr>
<td width="151"><strong>Piston backflushing</strong></td>
<td width="305">Passive; active available upon request</td>
</tr>
<tr>
<td width="151"><strong>Flow rate range</strong></td>
<td width="305">0.002 &#8211; 10.0 ml/min in 0.001 ml/min incrtements</td>
</tr>
<tr>
<td width="151"><strong>Flow rate precision</strong></td>
<td width="305">&lt; 0.07 % (RSD), 1 ml/min of methanol/water (8:2) at 200 bar</td>
</tr>
<tr>
<td width="151"><strong>Flow rate accuracy</strong></td>
<td width="305">&lt; 1 % or 10 µl/min, whatever is greater</td>
</tr>
<tr>
<td width="151"><strong>Pressure pulsation</strong></td>
<td width="305">&lt; 1 % or &lt;0.3 MPa (3 bar), whatever is greater</td>
</tr>
<tr>
<td width="151"><strong>Maximum operating pressure</strong></td>
<td width="305">85 MPa / 850 bar / 12300 psi</td>
</tr>
<tr>
<td width="151"><strong>System protection</strong></td>
<td width="305">Soft start, programmable minimum and maximum pressure limits</td>
</tr>
<tr>
<td width="151"><strong>Wetted materials</strong></td>
<td width="305">Titanium (capillaries, pump heads) Ceramic (pressure transducer) PTFE,PEEK (seals, draw-off valve) Sapphire (plungers)</p>
<p>Ruby, ceramic (check valves)</p>
<p>Pump head materials (stainless steel, Hastelloy C, ceramic, PEEK)</td>
</tr>
<tr>
<td width="151"><strong>Stand-alone</strong> <strong>operation</strong></td>
<td width="305">4” LCD with touch panel</td>
</tr>
<tr>
<td width="151"><strong>Remote operation</strong></td>
<td width="305">Start/Stop input</td>
</tr>
</tbody>
</table>
<p><span style="font-weight: 400;"> </span></p>
<table style="font-weight: 400;">
<tbody>
<tr>
<td width="151"></td>
<td width="305">Error output</p>
<p>Flow rate control input 0&#8230;10 V</p>
<p>Pressure signal analogue output 0..+2,5 V</td>
</tr>
<tr>
<td width="151"><strong>Communication</strong></td>
<td width="305">LAN 10/100 Mbit/s USB 2.0</td>
</tr>
<tr>
<td width="151"><strong>Power requirements</strong></td>
<td width="305">External power supply, 24 Vdc, 5 A max.</td>
</tr>
<tr>
<td width="151"><strong>Operating</strong> <strong>temperature</strong></td>
<td width="305">4 &#8211; 45 °C / 41 &#8211; 95 °F</td>
</tr>
<tr>
<td width="151"><strong>Humidity</strong></td>
<td width="305">0 &#8211; 90 %, non-condensing</td>
</tr>
<tr>
<td width="151"><strong>Weight without power supply</strong></td>
<td width="305">4 kg / 9 lbs</td>
</tr>
<tr>
<td width="151"><strong>Size</strong></td>
<td width="305">130 x 200 x 320 mm / 5.0 x 7.9 x 13.7 in. (W x H x D)</td>
</tr>
</tbody>
</table>
<p style="font-weight: 400;"><strong> </strong></p>
<p style="font-weight: 400;">Specifications are subject to change without notice</p>
<p style="font-weight: 400;">
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/anser-pmp-3010-double-piston-parallel-pump/">ANSER PMP-3010 Double Piston Parallel Pump</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>S 1525 Preparative Pump</title>
		<link>https://www.iconsci.com/shop/s-1525-preparative-pump/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Tue, 17 Nov 2020 20:43:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4629</guid>

					<description><![CDATA[<p>The S 1525 Preparative pump is the next generation of high-flow, high pressure pumps launched in 2018.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/s-1525-preparative-pump/">S 1525 Preparative Pump</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The S 1525 Preparative pump is the next generation of high-flow, high pressure pumps launched in 2018.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/s-1525-preparative-pump/">S 1525 Preparative Pump</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>S 1535 Preparative Pump</title>
		<link>https://www.iconsci.com/shop/s-1535-preparative-pump/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Tue, 17 Nov 2020 20:41:57 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4627</guid>

					<description><![CDATA[<p>The S 1535 Preparative pump is the next generation of high-flow, high pressure pumps launched in 2019.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/s-1535-preparative-pump/">S 1535 Preparative Pump</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The S 1535 Preparative pump is the next generation of high-flow, high pressure pumps launched in 2019.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/s-1535-preparative-pump/">S 1535 Preparative Pump</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>200L LPE Extraction System</title>
		<link>https://www.iconsci.com/shop/200l-lpe-extraction-system/</link>
		
		<dc:creator><![CDATA[David Cohen]]></dc:creator>
		<pubDate>Mon, 29 Jun 2020 17:52:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/?post_type=product&#038;p=4477</guid>

					<description><![CDATA[<p>200L_LPE</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/200l-lpe-extraction-system/">200L LPE Extraction System</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://www.iconsci.com/wp-content/uploads/2020/06/200L_LPE-1.pdf">200L_LPE</a></p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/200l-lpe-extraction-system/">200L LPE Extraction System</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AZURA P 2.1L</title>
		<link>https://www.iconsci.com/shop/azurap21l-ape20/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 12 Apr 2018 14:37:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/azurap21l-ape20/</guid>

					<description><![CDATA[<p>Preparative HPLC pump with 100 ml/min pump head, stainless steel</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurap21l-ape20/">AZURA P 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="art-nr">Preparative HPLC pump</p>
<p align="justify">AZURA preparative HPLC pump P 2.1L covers wide flow rate range and pressure capabilities. It has been designed for purification of mg and gram samples. The Mobile Control allows intuitive control in stand-alone operation. The integrated automatic recognition of the pump head with RFID technology allows fast adaptions of the pump for various applications.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Control</th>
<td>LAN; RS-232; analog and event controlled</td>
</tr>
<tr>
<th>Inputs</th>
<td>flow rate</td>
</tr>
<tr>
<th>Outputs</th>
<td>pressure; 8 event outputs (TTL, OC, relays)</td>
</tr>
<tr>
<th>Analog inputs</th>
<td>0-10 V</td>
</tr>
<tr>
<th>Analog outputs</th>
<td>1, 2 or 5 V</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 &#8211; 240 V, 50 &#8211; 60 Hz</td>
</tr>
<tr>
<th>Dimensions</th>
<td>361 x 208,2 x 523 mm (B x W D)</td>
</tr>
<tr>
<th>Weight</th>
<td>19 kg</td>
</tr>
<tr>
<th>Leak sensor</th>
<td>yes</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F<br />
air humidity: below 90 % humidity (non condensing)</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General Information</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Maximum viscosity</th>
<td>1000 cP</td>
</tr>
<tr>
<th>Liquid temperature range</th>
<td>4−60 °C (39.2−140 °F)</td>
</tr>
<tr>
<th>Gradient</th>
<td>Isocratic</td>
</tr>
<tr>
<th>Leak management</th>
<td>yes</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">Detailed information</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Flow rate accuracy</th>
<td>± 2 %</td>
</tr>
<tr>
<th>Flow rate accuracy conditions</th>
<td>measured at 5 &#8211; 50 % of flow range using ethanol/water 10:90</td>
</tr>
<tr>
<th>Flow rate precision</th>
<td>&lt; 0.1 % RSD</td>
</tr>
<tr>
<th>Flow rate precision conditions</th>
<td>measured at 5 &#8211; 50 % of flow range using ethanol/water 10:90</td>
</tr>
<tr>
<th>HPG: gradient accuracy</th>
<td>± 2 % (5 &#8211; 95 %, measured at 5 &#8211; 50 % of flow range, water/caffeine tracer)</td>
</tr>
<tr>
<th>HPG: gradient precision</th>
<td>1 % RSD, based on retention time at constant room temperature</td>
</tr>
<tr>
<th>LPG: gradient accuracy</th>
<td>± 3 % (5 &#8211; 95 %, measured at 5 &#8211; 50 % of the flow range, water/caffeine tracer)</td>
</tr>
<tr>
<th>LPG: gradient precision</th>
<td>2 % RSD, based on retention time at constant room</td>
</tr>
<tr>
<th>Active piston seal wash</th>
<td>+</td>
</tr>
<tr>
<th>Piston seal washing</th>
<td>+</td>
</tr>
<tr>
<th>Pump head inlet (standard)</th>
<td>M8 x 1 (flat bottom)</td>
</tr>
<tr>
<th>Pump head outlet (standard)</th>
<td>M8 x 1 (coned)</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Pumpe P 2.1L Benutzerhandbuch DE (V6840)</h2>
<p class="list-download__subline">
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">3.1 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurap21l-ape20/">AZURA P 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tungsten-Halogen lamp with base</title>
		<link>https://www.iconsci.com/shop/tungstenhalogenlampwithbase/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 10:53:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/tungstenhalogenlampwithbase/</guid>

					<description><![CDATA[<p>for converting Smartline UV 2500 detector into Smartline VIS 2500 detector</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/tungstenhalogenlampwithbase/">Tungsten-Halogen lamp with base</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Halogen lamp for converting Smartline UV 2500 detector into Smartline VIS 2500 detector. Required for the first installation.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/tungstenhalogenlampwithbase/">Tungsten-Halogen lamp with base</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tungsten-Halogen lamp</title>
		<link>https://www.iconsci.com/shop/tungstenhalogenlamp/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 10:49:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/tungstenhalogenlamp/</guid>

					<description><![CDATA[<p>for Smartline 2500 detector, VIS version</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/tungstenhalogenlamp/">Tungsten-Halogen lamp</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Halogen lamp for Smartline 2500 detector, VIS version.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/tungstenhalogenlamp/">Tungsten-Halogen lamp</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Deuterium Lamp</title>
		<link>https://www.iconsci.com/shop/deuteriumlamp/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 10:38:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/deuteriumlamp/</guid>

					<description><![CDATA[<p>for AZURA UVD 2.1S, UVD 2.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 detectors</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/deuteriumlamp/">Deuterium Lamp</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Deuterium replacement lamp for AZURA UVD 2.1S, UVD 2.1L, DAD 2.1L, MWD 2.1L and Smartline 2520 detectors. Original spare part.</p>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v6757_replacement_deuterium_lamp.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v6757_replacement_deuterium_lamp.png" alt="" width="24" height="24" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Replacement deuterium lamp Supplement EN (V6757)</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">191.4 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v6757_replacement_deuterium_lamp.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/deuteriumlamp/">Deuterium Lamp</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>D2 Lamp</title>
		<link>https://www.iconsci.com/shop/d2lamp/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 10:35:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/d2lamp/</guid>

					<description><![CDATA[<p>for Smartline 2500 and 2600 detectors</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/d2lamp/">D2 Lamp</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Deuterium lamp, 35 W, for Smartline 2500 and 2600 detectors.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/d2lamp/">D2 Lamp</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AZURA P 2.1L</title>
		<link>https://www.iconsci.com/shop/azurap21l-ape20na/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 12 Feb 2018 12:41:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/azurap21l-ape20na/</guid>

					<description><![CDATA[<p>1000 ml/min pump head, stainless steel</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurap21l-ape20na/">AZURA P 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Preparative HPLC pump</p>
<p>AZURA preparative HPLC pump P 2.1L covers wide flow rate range and pressure capabilities. It has been designed for purification of mg and gram samples. The Mobile Control allows intuitive control in stand-alone operation. The integrated automatic recognition of the pump head with RFID technology allows fast adaptions of the pump for various applications.</p>
<h1 class="headline">Technical Data</h1>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Control</th>
<td>LAN; RS-232; analog and event controlled</td>
</tr>
<tr>
<th>Inputs</th>
<td>flow rate</td>
</tr>
<tr>
<th>Outputs</th>
<td>pressure; 8 event outputs (TTL, OC, relays)</td>
</tr>
<tr>
<th>Analog inputs</th>
<td>0-10 V</td>
</tr>
<tr>
<th>Analog outputs</th>
<td>1, 2 or 5 V</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 &#8211; 240 V, 50 &#8211; 60 Hz</td>
</tr>
<tr>
<th>Dimensions</th>
<td>361 x 208,2 x 523 mm (B x W D)</td>
</tr>
<tr>
<th>Weight</th>
<td>19 kg</td>
</tr>
<tr>
<th>Leak sensor</th>
<td>yes</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F<br />
air humidity: below 90 % humidity (non condensing)</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">General Information</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Max. flow rate</th>
<td>1000 ml/min</td>
</tr>
<tr>
<th>Flow rate range</th>
<td>1-1000ml</td>
</tr>
<tr>
<th>Flow rate increment</th>
<td>0.1 ml/min</td>
</tr>
<tr>
<th>Maximum delivery pressure [psi]</th>
<td>730 psi</td>
</tr>
<tr>
<th>Maximum delivery pressure [bar]</th>
<td>50 bar</td>
</tr>
<tr>
<th>Maximum delivery pressure [MPa]</th>
<td>5 MPa</td>
</tr>
<tr>
<th>Pump head materials</th>
<td>Stainless Steel</td>
</tr>
<tr>
<th>Maximum viscosity</th>
<td>1000 cP</td>
</tr>
<tr>
<th>Liquid temperature range</th>
<td>4−60 °C (39.2−140 °F)</td>
</tr>
<tr>
<th>Gradient</th>
<td>isocratic</td>
</tr>
<tr>
<th>Leak management</th>
<td>yes</td>
</tr>
<tr>
<th>Wetted materials</th>
<td><span title="Stainless steel is, apart from PEEK, the standard material in HPLC. Steels with WNr. 1.4404 (316L) are used, or with a mixture of higher compatibility. They are inert against almost all solvents. Exceptions are biological applications which are metal ion sensible, and applications with extreme corrosive conditions. These steels, in comparison to commonly used steels, are increasingly resistant against hydrochloric acid, cyanides and other halogen acids, chlorides and chlorinated solvents. The use in ion cromatography is not recommended. In case of electrochemical applications, a passivation must be executed first.">stainless steel</span>, <span title="Due to their high resistance to wear and corrosion, aluminium oxide ceramics are used as a coating for mechanically stressed surfaces. They are a biocompatible material with low thermal conductivity and low thermal expansion.">aluminum oxide (Al<sub>2</sub>O<sub>3</sub>)</span>, <span title="The elastomer consisting of fluorinated hydrocarbon stands out due to a high resistance against mineral oils, synthetic hydraulic fluids, fuels, aromatics, and many organic solvents and chemicals. However, it is not compatible with strong alkaline solvents (pH value &gt;13) like ammonia, and acidic solvents (pH value &lt;1), pyrrole and THF. Operating temperature: Between -40 °C and +200 °C.">FKM</span>, <span title="PEEK is a durable and resistant plastic and, apart from stainless steel, the standard material in HPLC. It can be used at temperatures up to 100 °C and is highly chemical resistant against almost all commonly used solvents in a pH range of 1-12, 5. PEEK is potentially moderate resistant against oxidizing and reducing solvents. Therefore, following solvents should not be used: Concentrated and oxidizing acids (such as nitric acid solution, sulfuric acid), halogenated acids (such as hydrofluoric acid, hydrobromic acid) and gaseous halogens. Hydrochloric acid is approved for most applications. In addition, following solvents can have a swelling effect and may have an impact on the functionality of the built-in components: Methylene chloride, THF and DMSO in any concentration such as acetonitrile in higher concentrations. ">PEEK</span>, <span title="Synthetic ruby is monocrystalline aluminium oxide and has a red coloration by the addition of some chromium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Ruby is used as piston material in HPLC pumps.">ruby</span>, <span title="Synthetic sapphire is virtually pure monocrystalline aluminium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Sapphire is used as piston material in HPLC pumps.">sapphire</span>, GFP (graphite fiber reinforced PTFE)</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Detailed information</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Best working conditions</th>
<td>2-800 ml/min</td>
</tr>
<tr>
<th>Continous working conditions</th>
<td>2-400 ml/min</td>
</tr>
<tr>
<th>Flow rate accuracy</th>
<td>± 2 %</td>
</tr>
<tr>
<th>Flow rate accuracy conditions</th>
<td>measured at 5 &#8211; 50 % of flow range using ethanol/water 10:90</td>
</tr>
<tr>
<th>Flow rate precision</th>
<td>&lt; 0.1 % RSD</td>
</tr>
<tr>
<th>Flow rate precision conditions</th>
<td>measured at 5 &#8211; 50 % of flow range using ethanol/water 10:90</td>
</tr>
<tr>
<th>HPG: gradient accuracy</th>
<td>± 2 % (5 &#8211; 95 %, measured at 5 &#8211; 50 % of flow range, water/caffeine tracer)</td>
</tr>
<tr>
<th>HPG: gradient precision</th>
<td>1 % RSD, based on retention time at constant room temperature</td>
</tr>
<tr>
<th>LPG: gradient accuracy</th>
<td>± 3 % (5 &#8211; 95 %, measured at 5 &#8211; 50 % of the flow range, water/caffeine tracer)</td>
</tr>
<tr>
<th>LPG: gradient precision</th>
<td>2 % RSD, based on retention time at constant room</td>
</tr>
<tr>
<th>Active piston seal wash</th>
<td>+</td>
</tr>
<tr>
<th>Piston seal washing</th>
<td>+</td>
</tr>
<tr>
<th>Pump head inlet (standard)</th>
<td>M8 x 1 (flat bottom)</td>
</tr>
<tr>
<th>Pump head outlet (standard)</th>
<td>M8 x 1 (coned)</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Pumpe P 2.1L Benutzerhandbuch DE (V6840)</h2>
<p class="list-download__subline">
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">3.1 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">381.6 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurap21l-ape20na/">AZURA P 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AZURA P 2.1L</title>
		<link>https://www.iconsci.com/shop/azurap21l-ape20ma/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 12 Feb 2018 12:13:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/azurap21l-ape20ma/</guid>

					<description><![CDATA[<p>500 ml/min pump head, stainless steel</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurap21l-ape20ma/">AZURA P 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Preparative HPLC pump</p>
<p>AZURA preparative HPLC pump P 2.1L covers wide flow rate range and pressure capabilities. It has been designed for purification of mg and gram samples. The Mobile Control allows intuitive control in stand-alone operation. The integrated automatic recognition of the pump head with RFID technology allows fast adaptions of the pump for various applications.</p>
<h1 class="headline">Technical Data</h1>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Control</th>
<td>LAN; RS-232; analog and event controlled</td>
</tr>
<tr>
<th>Inputs</th>
<td>flow rate</td>
</tr>
<tr>
<th>Outputs</th>
<td>pressure; 8 event outputs (TTL, OC, relays)</td>
</tr>
<tr>
<th>Analog inputs</th>
<td>0-10 V</td>
</tr>
<tr>
<th>Analog outputs</th>
<td>1, 2 or 5 V</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 &#8211; 240 V, 50 &#8211; 60 Hz</td>
</tr>
<tr>
<th>Dimensions</th>
<td>361 x 208,2 x 523 mm (B x W D)</td>
</tr>
<tr>
<th>Weight</th>
<td>19 kg</td>
</tr>
<tr>
<th>Leak sensor</th>
<td>yes</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F<br />
air humidity: below 90 % humidity (non condensing)</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">General Information</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Max. flow rate</th>
<td>500 ml/min</td>
</tr>
<tr>
<th>Flow rate increment</th>
<td>0.01 ml/min</td>
</tr>
<tr>
<th>Maximum delivery pressure [psi]</th>
<td>1450 psi</td>
</tr>
<tr>
<th>Maximum delivery pressure [bar]</th>
<td>100 bar</td>
</tr>
<tr>
<th>Maximum delivery pressure [MPa]</th>
<td>10 MPa</td>
</tr>
<tr>
<th>Pump head materials</th>
<td>Stainless Steel</td>
</tr>
<tr>
<th>Maximum viscosity</th>
<td>1000 cP</td>
</tr>
<tr>
<th>Liquid temperature range</th>
<td>4−60 °C (39.2−140 °F)</td>
</tr>
<tr>
<th>Gradient</th>
<td>isocratic</td>
</tr>
<tr>
<th>Leak management</th>
<td>yes</td>
</tr>
<tr>
<th>Wetted materials</th>
<td><span title="Stainless steel is, apart from PEEK, the standard material in HPLC. Steels with WNr. 1.4404 (316L) are used, or with a mixture of higher compatibility. They are inert against almost all solvents. Exceptions are biological applications which are metal ion sensible, and applications with extreme corrosive conditions. These steels, in comparison to commonly used steels, are increasingly resistant against hydrochloric acid, cyanides and other halogen acids, chlorides and chlorinated solvents. The use in ion cromatography is not recommended. In case of electrochemical applications, a passivation must be executed first.">stainless steel</span>, <span title="Due to their high resistance to wear and corrosion, aluminium oxide ceramics are used as a coating for mechanically stressed surfaces. They are a biocompatible material with low thermal conductivity and low thermal expansion.">aluminum oxide (Al<sub>2</sub>O<sub>3</sub>)</span>, <span title="The elastomer consisting of fluorinated hydrocarbon stands out due to a high resistance against mineral oils, synthetic hydraulic fluids, fuels, aromatics, and many organic solvents and chemicals. However, it is not compatible with strong alkaline solvents (pH value &gt;13) like ammonia, and acidic solvents (pH value &lt;1), pyrrole and THF. Operating temperature: Between -40 °C and +200 °C.">FKM</span>, GFP (graphite fiber reinforced PTFE), <span title="PEEK is a durable and resistant plastic and, apart from stainless steel, the standard material in HPLC. It can be used at temperatures up to 100 °C and is highly chemical resistant against almost all commonly used solvents in a pH range of 1-12, 5. PEEK is potentially moderate resistant against oxidizing and reducing solvents. Therefore, following solvents should not be used: Concentrated and oxidizing acids (such as nitric acid solution, sulfuric acid), halogenated acids (such as hydrofluoric acid, hydrobromic acid) and gaseous halogens. Hydrochloric acid is approved for most applications. In addition, following solvents can have a swelling effect and may have an impact on the functionality of the built-in components: Methylene chloride, THF and DMSO in any concentration such as acetonitrile in higher concentrations. ">PEEK</span>, <span title="Synthetic ruby is monocrystalline aluminium oxide and has a red coloration by the addition of some chromium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Ruby is used as piston material in HPLC pumps.">ruby</span>, <span title="Synthetic sapphire is virtually pure monocrystalline aluminium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Sapphire is used as piston material in HPLC pumps.">sapphire</span></td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Detailed information</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Best working conditions</th>
<td>1-400 ml/min</td>
</tr>
<tr>
<th>Continous working conditions</th>
<td>2-200 ml/min</td>
</tr>
<tr>
<th>Flow rate accuracy</th>
<td>± 2 %</td>
</tr>
<tr>
<th>Flow rate accuracy conditions</th>
<td>measured at 5 &#8211; 50 % of flow range using ethanol/water 10:90</td>
</tr>
<tr>
<th>Flow rate precision</th>
<td>&lt; 0.1 % RSD</td>
</tr>
<tr>
<th>Flow rate precision conditions</th>
<td>measured at 5 &#8211; 50 % of flow range using ethanol/water 10:90</td>
</tr>
<tr>
<th>HPG: gradient accuracy</th>
<td>± 2 % (5 &#8211; 95 %, measured at 5 &#8211; 50 % of flow range, water/caffeine tracer)</td>
</tr>
<tr>
<th>HPG: gradient precision</th>
<td>1 % RSD, based on retention time at constant room temperature</td>
</tr>
<tr>
<th>LPG: gradient accuracy</th>
<td>± 3 % (5 &#8211; 95 %, measured at 5 &#8211; 50 % of the flow range, water/caffeine tracer)</td>
</tr>
<tr>
<th>LPG: gradient precision</th>
<td>2 % RSD, based on retention time at constant room</td>
</tr>
<tr>
<th>Active piston seal wash</th>
<td>+</td>
</tr>
<tr>
<th>Piston seal washing</th>
<td>+</td>
</tr>
<tr>
<th>Pump head inlet (standard)</th>
<td>M8 x 1 (flat bottom)</td>
</tr>
<tr>
<th>Pump head outlet (standard)</th>
<td>M8 x 1 (coned)</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Pumpe P 2.1L Benutzerhandbuch DE (V6840)</h2>
<p class="list-download__subline">
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">3.1 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">381.6 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurap21l-ape20ma/">AZURA P 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AZURA P 2.1L</title>
		<link>https://www.iconsci.com/shop/azurap21l-ape20la/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Fri, 09 Feb 2018 18:48:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/azurap21l-ape20la/</guid>

					<description><![CDATA[<p>250 ml/min pump head, stainless steel</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurap21l-ape20la/">AZURA P 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Preparative HPLC pump</p>
<p>AZURA preparative HPLC pump P 2.1L covers wide flow rate range and pressure capabilities. It has been designed for purification of mg and gram samples. The Mobile Control allows intuitive control in stand-alone operation. The integrated automatic recognition of the pump head with RFID technology allows fast adaptions of the pump for various applications.</p>
<h1 class="headline">Technical Data</h1>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Control</th>
<td>LAN; RS-232; analog and event controlled</td>
</tr>
<tr>
<th>Inputs</th>
<td>flow rate</td>
</tr>
<tr>
<th>Outputs</th>
<td>pressure; 8 event outputs (TTL, OC, relays)</td>
</tr>
<tr>
<th>Analog inputs</th>
<td>0-10 V</td>
</tr>
<tr>
<th>Analog outputs</th>
<td>1, 2 or 5 V</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 &#8211; 240 V, 50 &#8211; 60 Hz</td>
</tr>
<tr>
<th>Dimensions</th>
<td>361 x 208,2 x 523 mm (B x W D)</td>
</tr>
<tr>
<th>Weight</th>
<td>19 kg</td>
</tr>
<tr>
<th>Leak sensor</th>
<td>yes</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F<br />
air humidity: below 90 % humidity (non condensing)</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">General Information</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Max. flow rate</th>
<td>250 ml/min</td>
</tr>
<tr>
<th>Flow rate increment</th>
<td>0.01 ml/min</td>
</tr>
<tr>
<th>Maximum delivery pressure [psi]</th>
<td>2900 psi</td>
</tr>
<tr>
<th>Maximum delivery pressure [bar]</th>
<td>200 bar</td>
</tr>
<tr>
<th>Maximum delivery pressure [MPa]</th>
<td>20 MPa</td>
</tr>
<tr>
<th>Pump head materials</th>
<td>Stainless Steel</td>
</tr>
<tr>
<th>Maximum viscosity</th>
<td>1000 cP</td>
</tr>
<tr>
<th>Liquid temperature range</th>
<td>4−60 °C (39.2−140 °F)</td>
</tr>
<tr>
<th>Gradient</th>
<td>isocratic</td>
</tr>
<tr>
<th>Leak management</th>
<td>yes</td>
</tr>
<tr>
<th>Wetted materials</th>
<td><span title="Stainless steel is, apart from PEEK, the standard material in HPLC. Steels with WNr. 1.4404 (316L) are used, or with a mixture of higher compatibility. They are inert against almost all solvents. Exceptions are biological applications which are metal ion sensible, and applications with extreme corrosive conditions. These steels, in comparison to commonly used steels, are increasingly resistant against hydrochloric acid, cyanides and other halogen acids, chlorides and chlorinated solvents. The use in ion cromatography is not recommended. In case of electrochemical applications, a passivation must be executed first.">stainless steel</span>, <span title="Due to their high resistance to wear and corrosion, aluminium oxide ceramics are used as a coating for mechanically stressed surfaces. They are a biocompatible material with low thermal conductivity and low thermal expansion.">aluminum oxide (Al<sub>2</sub>O<sub>3</sub>)</span>, <span title="The elastomer consisting of fluorinated hydrocarbon stands out due to a high resistance against mineral oils, synthetic hydraulic fluids, fuels, aromatics, and many organic solvents and chemicals. However, it is not compatible with strong alkaline solvents (pH value &gt;13) like ammonia, and acidic solvents (pH value &lt;1), pyrrole and THF. Operating temperature: Between -40 °C and +200 °C.">FKM</span>, GFP (graphite fiber reinforced PTFE), <span title="PEEK is a durable and resistant plastic and, apart from stainless steel, the standard material in HPLC. It can be used at temperatures up to 100 °C and is highly chemical resistant against almost all commonly used solvents in a pH range of 1-12, 5. PEEK is potentially moderate resistant against oxidizing and reducing solvents. Therefore, following solvents should not be used: Concentrated and oxidizing acids (such as nitric acid solution, sulfuric acid), halogenated acids (such as hydrofluoric acid, hydrobromic acid) and gaseous halogens. Hydrochloric acid is approved for most applications. In addition, following solvents can have a swelling effect and may have an impact on the functionality of the built-in components: Methylene chloride, THF and DMSO in any concentration such as acetonitrile in higher concentrations. ">PEEK</span>, <span title="Synthetic ruby is monocrystalline aluminium oxide and has a red coloration by the addition of some chromium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Ruby is used as piston material in HPLC pumps.">ruby</span>, <span title="Synthetic sapphire is virtually pure monocrystalline aluminium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Sapphire is used as piston material in HPLC pumps.">sapphire</span></td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Detailed information</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Best working conditions</th>
<td>0.01-200 ml/min</td>
</tr>
<tr>
<th>Continous working conditions</th>
<td>0.1-100 ml/min</td>
</tr>
<tr>
<th>Flow rate accuracy</th>
<td>± 2 %</td>
</tr>
<tr>
<th>Flow rate accuracy conditions</th>
<td>measured at 5 &#8211; 50 % of flow range using ethanol/water 10:90</td>
</tr>
<tr>
<th>Flow rate precision</th>
<td>&lt; 0.1 % RSD</td>
</tr>
<tr>
<th>Flow rate precision conditions</th>
<td>measured at 5 &#8211; 50 % of flow range using ethanol/water 10:90</td>
</tr>
<tr>
<th>HPG: gradient accuracy</th>
<td>± 2 % (5 &#8211; 95 %, measured at 5 &#8211; 50 % of flow range, water/caffeine tracer)</td>
</tr>
<tr>
<th>HPG: gradient precision</th>
<td>1 % RSD, based on retention time at constant room temperature</td>
</tr>
<tr>
<th>LPG: gradient accuracy</th>
<td>± 3 % (5 &#8211; 95 %, measured at 5 &#8211; 50 % of the flow range, water/caffeine tracer)</td>
</tr>
<tr>
<th>LPG: gradient precision</th>
<td>2 % RSD, based on retention time at constant room</td>
</tr>
<tr>
<th>Active piston seal wash</th>
<td>+</td>
</tr>
<tr>
<th>Piston seal washing</th>
<td>+</td>
</tr>
<tr>
<th>Pump head inlet (standard)</th>
<td>M8 x 1 (flat bottom)</td>
</tr>
<tr>
<th>Pump head outlet (standard)</th>
<td>M8 x 1 (coned)</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Pumpe P 2.1L Benutzerhandbuch DE (V6840)</h2>
<p class="list-download__subline">
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">3.1 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">381.6 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurap21l-ape20la/">AZURA P 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AZURA P 2.1L</title>
		<link>https://www.iconsci.com/shop/azurap21l-ape20ka/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Fri, 09 Feb 2018 18:27:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/azurap21l-ape20ka/</guid>

					<description><![CDATA[<p>100 ml/min pump head, stainless steel</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurap21l-ape20ka/">AZURA P 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Preparative HPLC pump</p>
<p>AZURA preparative HPLC pump P 2.1L covers wide flow rate range and pressure capabilities. It has been designed for purification of mg and gram samples. The Mobile Control allows intuitive control in stand-alone operation. The integrated automatic recognition of the pump head with RFID technology allows fast adaptions of the pump for various applications.</p>
<h1 class="headline">Technical Data</h1>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Control</th>
<td>LAN; RS-232; analog and event controlled</td>
</tr>
<tr>
<th>Inputs</th>
<td>flow rate</td>
</tr>
<tr>
<th>Outputs</th>
<td>pressure; 8 event outputs (TTL, OC, relays)</td>
</tr>
<tr>
<th>Analog inputs</th>
<td>0-10 V</td>
</tr>
<tr>
<th>Analog outputs</th>
<td>1, 2 or 5 V</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>100 &#8211; 240 V, 50 &#8211; 60 Hz</td>
</tr>
<tr>
<th>Dimensions</th>
<td>361 x 208,2 x 523 mm (B x W D)</td>
</tr>
<tr>
<th>Weight</th>
<td>19 kg</td>
</tr>
<tr>
<th>Leak sensor</th>
<td>yes</td>
</tr>
<tr>
<th>Ambient conditions</th>
<td>temperature range: 10–40 °C; 50–104 °F<br />
air humidity: below 90 % humidity (non condensing)</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">General Information</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Max. flow rate</th>
<td>100 ml/min</td>
</tr>
<tr>
<th>Flow rate increment</th>
<td>0.01 ml/min</td>
</tr>
<tr>
<th>Maximum delivery pressure [psi]</th>
<td>5800 psi</td>
</tr>
<tr>
<th>Maximum delivery pressure [bar]</th>
<td>400 bar</td>
</tr>
<tr>
<th>Maximum delivery pressure [MPa]</th>
<td>40 MPa</td>
</tr>
<tr>
<th>Pump head materials</th>
<td>Stainless Steel</td>
</tr>
<tr>
<th>Maximum viscosity</th>
<td>1000 cP</td>
</tr>
<tr>
<th>Liquid temperature range</th>
<td>4−60 °C (39.2−140 °F)</td>
</tr>
<tr>
<th>Gradient</th>
<td>isocratic</td>
</tr>
<tr>
<th>Leak management</th>
<td>yes</td>
</tr>
<tr>
<th>Wetted materials</th>
<td><span title="Stainless steel is, apart from PEEK, the standard material in HPLC. Steels with WNr. 1.4404 (316L) are used, or with a mixture of higher compatibility. They are inert against almost all solvents. Exceptions are biological applications which are metal ion sensible, and applications with extreme corrosive conditions. These steels, in comparison to commonly used steels, are increasingly resistant against hydrochloric acid, cyanides and other halogen acids, chlorides and chlorinated solvents. The use in ion cromatography is not recommended. In case of electrochemical applications, a passivation must be executed first.">stainless steel</span>, GFP (graphite fiber reinforced PTFE), <span title="The elastomer consisting of fluorinated hydrocarbon stands out due to a high resistance against mineral oils, synthetic hydraulic fluids, fuels, aromatics, and many organic solvents and chemicals. However, it is not compatible with strong alkaline solvents (pH value &gt;13) like ammonia, and acidic solvents (pH value &lt;1), pyrrole and THF. Operating temperature: Between -40 °C and +200 °C.">FKM</span>, <span title="PEEK is a durable and resistant plastic and, apart from stainless steel, the standard material in HPLC. It can be used at temperatures up to 100 °C and is highly chemical resistant against almost all commonly used solvents in a pH range of 1-12, 5. PEEK is potentially moderate resistant against oxidizing and reducing solvents. Therefore, following solvents should not be used: Concentrated and oxidizing acids (such as nitric acid solution, sulfuric acid), halogenated acids (such as hydrofluoric acid, hydrobromic acid) and gaseous halogens. Hydrochloric acid is approved for most applications. In addition, following solvents can have a swelling effect and may have an impact on the functionality of the built-in components: Methylene chloride, THF and DMSO in any concentration such as acetonitrile in higher concentrations. ">PEEK</span>, <span title="Synthetic sapphire is virtually pure monocrystalline aluminium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Sapphire is used as piston material in HPLC pumps.">sapphire</span>, <span title="Synthetic ruby is monocrystalline aluminium oxide and has a red coloration by the addition of some chromium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Ruby is used as piston material in HPLC pumps.">ruby</span>, <span title="Due to their high resistance to wear and corrosion, aluminium oxide ceramics are used as a coating for mechanically stressed surfaces. They are a biocompatible material with low thermal conductivity and low thermal expansion.">aluminum oxide (Al<sub>2</sub>O<sub>3</sub>)</span></td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Detailed information</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Best working conditions</th>
<td>0.01-80 ml/min</td>
</tr>
<tr>
<th>Continous working conditions</th>
<td>0.1-40 ml/min</td>
</tr>
<tr>
<th>Flow rate accuracy</th>
<td>± 2 %</td>
</tr>
<tr>
<th>Flow rate accuracy conditions</th>
<td>measured at 5 &#8211; 50 % of flow range using ethanol/water 10:90</td>
</tr>
<tr>
<th>Flow rate precision</th>
<td>&lt; 0.1 % RSD</td>
</tr>
<tr>
<th>Flow rate precision conditions</th>
<td>measured at 5 &#8211; 50 % of flow range using ethanol/water 10:90</td>
</tr>
<tr>
<th>HPG: gradient accuracy</th>
<td>± 2 % (5 &#8211; 95 %, measured at 5 &#8211; 50 % of flow range, water/caffeine tracer)</td>
</tr>
<tr>
<th>HPG: gradient precision</th>
<td>1 % RSD, based on retention time at constant room temperature</td>
</tr>
<tr>
<th>LPG: gradient accuracy</th>
<td>± 3 % (5 &#8211; 95 %, measured at 5 &#8211; 50 % of the flow range, water/caffeine tracer)</td>
</tr>
<tr>
<th>LPG: gradient precision</th>
<td>2 % RSD, based on retention time at constant room</td>
</tr>
<tr>
<th>Active piston seal wash</th>
<td>+</td>
</tr>
<tr>
<th>Piston seal washing</th>
<td>+</td>
</tr>
<tr>
<th>Pump head inlet (standard)</th>
<td>M8 x 1 (flat bottom)</td>
</tr>
<tr>
<th>Pump head outlet (standard)</th>
<td>M8 x 1 (coned)</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Pumpe P 2.1L Benutzerhandbuch DE (V6840)</h2>
<p class="list-download__subline">
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">3.1 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/v6840_azura_p_2.1l_benutzerhandbuch_de.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">381.6 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azurap21l-ape20ka/">AZURA P 2.1L</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
