<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fluorescence detectors &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/fluorescence-detectors/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Wed, 28 Feb 2018 15:25:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>Fluorescence detectors &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Fluorescence Detector RF-20 Axs</title>
		<link>https://www.iconsci.com/shop/fluorescencedetectorrf20axs/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 28 Feb 2018 15:25:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/fluorescencedetectorrf20axs/</guid>

					<description><![CDATA[<p>200 - 750 nm, fluorescence detector, including accessories</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/fluorescencedetectorrf20axs/">Fluorescence Detector RF-20 Axs</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The fluorescence detector RF-20Axs provides world-class sensitivity, excellent maintainability and diverse validation / support functions. It supports a wide range of applications in the wavelength range of 200 to 750 nm from conventional analysis to high-performance analysis.With a signal-to-noise ratio of 2000 for the water-Raman band, the fluorescence detector is very well suited for trace analysis.Measuring cell tempering ensures the lowest possible noise and drift values</p>
<p>The integrated low-pressure mercury lamp allows easy wavelength accuracy verification. The xenon lamp and flow cell are directly accessible on the device, thus allowing a quick and easy handling and maintenance of the device by the user, thereby minimizing downtime. The lamp life is 2000 hours. When replacing the xenon lamp, no adjustment is required.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Detection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Detector type</th>
<td>Fluorescence detector</td>
</tr>
<tr>
<th>Detection channels</th>
<td>2</td>
</tr>
<tr>
<th>Number of signals</th>
<td>2</td>
</tr>
<tr>
<th>Light source</th>
<td>xenon lamp, low-pressure; mercury lamp for wavelength accuracy check</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>200 &#8211; 750 nm</td>
</tr>
<tr>
<th>Spectral bandwidth</th>
<td>20 nm</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2 nm</td>
</tr>
<tr>
<th>Wavelength precision</th>
<td>± 0.2 nm Indicates the precision performance when the power is turned ON in single wavelength mode and the wavelength is changed.</td>
</tr>
<tr>
<th>Sensitivity</th>
<td>can be set at three levels: HIGH (x 1), MED (x 32), LOW (x 1024)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>SUS316L, PTFE (fluorocarbon polymers), quartz</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>12 µl</td>
</tr>
<tr>
<th>Time constants</th>
<td>11 levels can be selected, equivalent to &#8220;no filter&#8221;, 0.05, 0.1, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0, 8.0 and 10.0 seconds</td>
</tr>
<tr>
<th>Autozero</th>
<td>auto zero function, basline shift function</td>
</tr>
</tbody>
</table>
</div>
<div class="hzone">
<h2 class="table-module__header">Heated zone</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Temperature range</th>
<td>room temperature (ambient temperature) -10 °C up to 40 °C (at flow rates less than 2 ml/min, column oven temperatures less than 85 °C)</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Gain</th>
<td>can be set at three levels: x 1, x 4, x 16</td>
</tr>
</tbody>
</table>
</div>
<div class="tzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>operating temperature: 4 to 35 °C, relative humidity: 20 to 85 % (no condensation)</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>AC220–240 V, 400 VA, 50/60 Hz</td>
</tr>
<tr>
<th>Dimensions</th>
<td>260 x 210 x 420 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>18 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/rf-20a20axs_im_de.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/rf-20a20axs_im_de.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Fluoreszenz-Detektor RF-20A/20Axs Benutzerhandbuch DE</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">10.6 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/rf-20a20axs_im_de.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/rf-20a20axs_im_en.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/rf-20a20axs_im_en.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Fluorescence Detector RF-20A/20Axs User Manual EN</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">10.4 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/rf-20a20axs_im_en.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/fluorescencedetectorrf20axs/">Fluorescence Detector RF-20 Axs</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluorescence Detector RF-20 A</title>
		<link>https://www.iconsci.com/shop/fluorescencedetectorrf20a/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 28 Feb 2018 15:11:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/fluorescencedetectorrf20a/</guid>

					<description><![CDATA[<p>200 - 650 nm, fluorescence detector, including accessories</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/fluorescencedetectorrf20a/">Fluorescence Detector RF-20 A</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The fluorescence detector RF-20A provides world-class sensitivity, excellent maintainability and diverse validation / support functions. It supports a wide range of applications in the wavelength range of 200 to 650 nm from conventional analysis to high-performance analysis.With a signal-to-noise ratio of 1200 for the water-Raman band, the fluorescence detector is well suited for trace analysis.The xenon lamp and flow cell are directly accessible on the device, thus allowing a quick and easy handling and maintenance of the device by the user, thereby minimizing downtime.The lamp life is 2000 hours. When replacing the xenon lamp, no adjustment is required.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Detection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Detector type</th>
<td>Fluorescence detector</td>
</tr>
<tr>
<th>Detection channels</th>
<td>1</td>
</tr>
<tr>
<th>Number of signals</th>
<td>1</td>
</tr>
<tr>
<th>Light source</th>
<td>xenon lamp</td>
</tr>
<tr>
<th>Wavelength range</th>
<td>200 &#8211; 650 nm</td>
</tr>
<tr>
<th>Spectral bandwidth</th>
<td>20 nm</td>
</tr>
<tr>
<th>Wavelength accuracy</th>
<td>± 2 nm</td>
</tr>
<tr>
<th>Wavelength precision</th>
<td>± 0.2 nm Indicates the precision performance when the power is turned ON in the single wavelength mode and the wavelength is changed.</td>
</tr>
<tr>
<th>Sensitivity</th>
<td>can be set at three levels: HIGH (x 1), MED (x 32), LOW (x 1024)</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>SUS316L, PTFE (fluorocarbon polymers), quartz</td>
</tr>
<tr>
<th>Flow cell volume</th>
<td>12 µl</td>
</tr>
<tr>
<th>Time constants</th>
<td>11 levels can be selected, equivalent to &#8220;no filter&#8221;, 0.05, 0.1, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0, 8.0 and 10.0 seconds</td>
</tr>
<tr>
<th>Autozero</th>
<td>auto zero function, basline shift function</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Gain</th>
<td>can be set at three levels: x 1, x 4, x 16</td>
</tr>
</tbody>
</table>
</div>
<div class="hzone">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Ambient conditions</th>
<td>operating temperature: 4 to 35 °C, relative humidity: 20 to 85 % (no condensation)</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>AC220–240 V, 400 VA, 50/60 Hz</td>
</tr>
<tr>
<th>Dimensions</th>
<td>260 x 210 x 420 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>16 kg</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/rf-20a20axs_im_de.png" media="(max-width: 400px)" /></picture>
<picture><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/rf-20a20axs_im_de.png" alt="" /></picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Fluoreszenz-Detektor RF-20A/20Axs Benutzerhandbuch DE</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">German</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">10.6 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/rf-20a20axs_im_de.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/rf-20a20axs_im_en.png" media="(max-width: 400px)" /></picture>
<picture><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/rf-20a20axs_im_en.png" alt="" /></picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Fluorescence Detector RF-20A/20Axs User Manual EN</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">10.4 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/rf-20a20axs_im_en.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">List of supported devices in chromatography data systems EN (V1663)</h2>
<p class="list-download__subline">Device support in KNAUER CDS / KNAUER device support in 3rd party software</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">information</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">328.1 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/supported_knauer_instruments_in_knauer_software.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/fluorescencedetectorrf20a/">Fluorescence Detector RF-20 A</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
