<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Flowmeter &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/flowmeter/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Mon, 27 Aug 2018 16:21:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>Flowmeter &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Mini CORI-Flow (M12) flowmeter</title>
		<link>https://www.iconsci.com/shop/minicoriflowm12flowmeter/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 27 Aug 2018 16:21:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/minicoriflowm12flowmeter/</guid>

					<description><![CDATA[<p>with mounting block</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/minicoriflowm12flowmeter/">Mini CORI-Flow (M12) flowmeter</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">with mounting block</p>
<p align="justify">Mini CORI-Flow are precise and compact mass flowmeters and controllers, based on the Coriolis measuring principle. Coriolis flowmeters are unmatched in accuracy. When applied for liquids, the mass flow accuracy is better than ±0,2% Rd.</p>
<p align="justify">Instruments of the mini CORI-Flow series contain a uniquely shaped, single loop sensor tube, forming part of an oscillating system. When a fluid flows through the tube, Coriolis forces cause a variable phase shift, which is detected by sensors and fed into the integrally mounted pc-board. The resulting output signal is strictly proportional to the real mass flow rate. The mini CORI-Flow features density and temperature of the fluid as secondary outputs.</p>
<h2 class="headline">Technical Data</h2>
<div class="ginfo">
<h2 class="table-module__header">Flowmeter</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Flow rate range</th>
<td>0.03 &#8211; 3.3 ml/min</td>
</tr>
<tr>
<th>Flow rate accuracy</th>
<td>± 0.2 % of rate *</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>stainless steel AISI 316 or equivalent optional Hastelloy-C22</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Communication</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Outputs</th>
<td>0 – 5 (10) Vdc or (0) 4 – 20 mA</td>
</tr>
<tr>
<th>Control</th>
<td>standard: RS–232 (8-pinDIN male connection) Profibus-DP® bus:(5-pin M12 female; power 8-pin DIN male) DeviceNet™ Modebus-RTU; LonWorks Flow bus (5–pin M12 male)</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">General</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Power supply</th>
<td>+15–24VDC ±10 % max. ripple recommended: 50mV tt</td>
</tr>
<tr>
<th>Weight</th>
<td>Meter: 1.2 kg Controller: 1.7 kg</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Other</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Note</th>
<td>* optimal accuracy will be reach after approx. 30 minutes after instrument power up</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/b_e_fm_bronkhorst_mini_coriflow.jpeg" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/b_e_fm_bronkhorst_mini_coriflow.jpeg" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Flowmeter mini Cori-Flow</h2>
<p class="list-download__subline">Flowmeter mini Cori-Flow</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Brochure</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">1.2 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="https://www.iconsci.com/wp-content/uploads/2019/09/m14_mini_cori-flow.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/minicoriflowm12flowmeter/">Mini CORI-Flow (M12) flowmeter</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mini CORI-Flow (M13) flowmeter</title>
		<link>https://www.iconsci.com/shop/minicoriflowm13flowmeter-a5393/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 27 Aug 2018 16:14:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/minicoriflowm13flowmeter-a5393/</guid>

					<description><![CDATA[<p>with mounting block and PROFIBUS interface</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/minicoriflowm13flowmeter-a5393/">Mini CORI-Flow (M13) flowmeter</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">with mounting block and PROFIBUS interface</p>
<p align="justify">Mini CORI-Flow are precise and compact mass flowmeters and controllers, based on the Coriolis measuring principle. Coriolis flowmeters are unmatched in accuracy. When applied for liquids, the mass flow accuracy is better than ±0,2% Rd.</p>
<p align="justify">Instruments of the mini CORI-Flow series contain a uniquely shaped, single loop sensor tube, forming part of an oscillating system. When a fluid flows through the tube, Coriolis forces cause a variable phase shift, which is detected by sensors and fed into the integrally mounted pc-board. The resulting output signal is strictly proportional to the real mass flow rate. The mini CORI-Flow features density and temperature of the fluid as secondary outputs.</p>
<h2 class="headline">Technical Data</h2>
<div class="ginfo">
<h2 class="table-module__header">Flowmeter</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Flow rate range</th>
<td>0.2 &#8211; 50 ml/min</td>
</tr>
<tr>
<th>Flow rate accuracy</th>
<td>± 0.2 % of rate *</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>stainless steel AISI 316 or equivalent optional Hastelloy-C22</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Communication</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Outputs</th>
<td>0 – 5 (10) Vdc or 0 (4) – 20 mA</td>
</tr>
<tr>
<th>Control</th>
<td>standard: RS–232 (8-pinDIN male connection) Profibus-DP® bus:(5-pin M12 female; power 8-pin DIN male) DeviceNet™ Modebus-RTU; LonWorks Flow bus (5–pin M12 male)</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Technical parameters</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Special features</th>
<td>additional: Profibus interface</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">General</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Power supply</th>
<td>+15–24VDC ±10 % max. ripple recommended: 50mV tt</td>
</tr>
<tr>
<th>Weight</th>
<td>Meter: 1.2 kg Controller: 1.7 kg</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Other</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Note</th>
<td>* optimal accuracy will be reach after approx. 30 minutes after instrument power up</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/b_e_fm_bronkhorst_mini_coriflow.jpeg" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/b_e_fm_bronkhorst_mini_coriflow.jpeg" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Flowmeter mini Cori-Flow</h2>
<p class="list-download__subline">Flowmeter mini Cori-Flow</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Brochure</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">1.2 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="https://www.iconsci.com/wp-content/uploads/2019/09/m14_mini_cori-flow.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/minicoriflowm13flowmeter-a5393/">Mini CORI-Flow (M13) flowmeter</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Upgrade-Kit Flowmeter for AZURA Lab SMB</title>
		<link>https://www.iconsci.com/shop/upgradekitflowmeterforazuralabsmb/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 27 Aug 2018 16:08:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/upgradekitflowmeterforazuralabsmb/</guid>

					<description><![CDATA[<p>One CORI Flow M13 for AZURA SMB System</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/upgradekitflowmeterforazuralabsmb/">Upgrade-Kit Flowmeter for AZURA Lab SMB</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>One CORI Flow M13 for AZURA SMB System</p>
<p align="justify">Use the CORI-Flow M13 to monitor your SMB process and ensure to see every small change in your conditions. The flowmeter are integrated in our SMB software PurityChrom MCC, so you can easily monitor your process and log the flowrate during the whole separation process. Typically two flowmeters are used to monitor the process. Up to four can be included into the system.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/upgradekitflowmeterforazuralabsmb/">Upgrade-Kit Flowmeter for AZURA Lab SMB</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mini CORI-Flow (M13) flowmeter (Hastelloy)</title>
		<link>https://www.iconsci.com/shop/minicoriflowm13flowmeterhastelloy/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 27 Aug 2018 16:00:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/minicoriflowm13flowmeterhastelloy/</guid>

					<description><![CDATA[<p>with mounting block</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/minicoriflowm13flowmeterhastelloy/">Mini CORI-Flow (M13) flowmeter (Hastelloy)</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">with mounting block</p>
<p align="justify">Mini CORI-Flow are precise and compact mass flowmeters and controllers, based on the Coriolis measuring principle. Coriolis flowmeters are unmatched in accuracy. When applied for liquids, the mass flow accuracy is better than ±0,2% Rd.</p>
<p align="justify">Instruments of the mini CORI-Flow series contain a uniquely shaped, single loop sensor tube, forming part of an oscillating system. When a fluid flows through the tube, Coriolis forces cause a variable phase shift, which is detected by sensors and fed into the integrally mounted pc-board. The resulting output signal is strictly proportional to the real mass flow rate. The mini CORI-Flow features density and temperature of the fluid as secondary outputs.</p>
<h2 class="headline">Technical Data</h2>
<div class="ginfo">
<h2 class="table-module__header">Flowmeter</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Flow rate range</th>
<td>0.2 &#8211; 50 ml/min</td>
</tr>
<tr>
<th>Flow rate accuracy</th>
<td>± 0.2 % of rate *</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>stainless steel AISI 316 or equivalent optional Hastelloy-C22</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Communication</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Outputs</th>
<td>0 – 5 (10) Vdc or 0 (4) – 20 mA</td>
</tr>
<tr>
<th>Control</th>
<td>standard: RS–232 (8-pinDIN male connection) Profibus-DP® bus:(5-pin M12 female; power 8-pin DIN male) DeviceNet™ Modebus-RTU; LonWorks Flow bus (5–pin M12 male)</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">General</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Power supply</th>
<td>+15–24VDC ±10 % max. ripple recommended: 50mV tt</td>
</tr>
<tr>
<th>Weight</th>
<td>Meter: 1.2 kg Controller: 1.7 kg</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Other</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Note</th>
<td>* optimal accuracy will be reach after approx. 30 minutes after instrument power up</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/b_e_fm_bronkhorst_mini_coriflow.jpeg" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/b_e_fm_bronkhorst_mini_coriflow.jpeg" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Flowmeter mini Cori-Flow</h2>
<p class="list-download__subline">Flowmeter mini Cori-Flow</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Brochure</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">1.2 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="https://www.iconsci.com/wp-content/uploads/2019/09/m14_mini_cori-flow.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/minicoriflowm13flowmeterhastelloy/">Mini CORI-Flow (M13) flowmeter (Hastelloy)</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mini CORI-Flow (M14) flowmeter</title>
		<link>https://www.iconsci.com/shop/minicoriflowm14flowmeter/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 27 Aug 2018 15:45:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/minicoriflowm14flowmeter/</guid>

					<description><![CDATA[<p>with mounting block</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/minicoriflowm14flowmeter/">Mini CORI-Flow (M14) flowmeter</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">with mounting block</p>
<p align="justify">Mini CORI-Flow are precise and compact mass flowmeters and controllers, based on the Coriolis measuring principle. Coriolis flowmeters are unmatched in accuracy. When applied for liquids, the mass flow accuracy is better than ±0,2% Rd.</p>
<p align="justify">Instruments of the mini CORI-Flow series contain a uniquely shaped, single loop sensor tube, forming part of an oscillating system. When a fluid flows through the tube, Coriolis forces cause a variable phase shift, which is detected by sensors and fed into the integrally mounted pc-board. The resulting output signal is strictly proportional to the real mass flow rate. The mini CORI-Flow features density and temperature of the fluid as secondary outputs.</p>
<h2 class="headline">Technical Data</h2>
<div class="ginfo">
<h2 class="table-module__header">Flowmeter</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Flow rate range</th>
<td>2 &#8211; 800 ml/min</td>
</tr>
<tr>
<th>Flow rate accuracy</th>
<td>± 0.2 % of rate *</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>stainless steel AISI 316 or equivalent optional Hastelloy-C22</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Communication</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Outputs</th>
<td>0 – 5 (10) Vdc or 0 (4) – 20 mA</td>
</tr>
<tr>
<th>Control</th>
<td>standard: RS–232 (8-pinDIN male connection) Profibus-DP® bus:(5-pin M12 female; power 8-pin DIN male) DeviceNet™ Modebus-RTU; LonWorks Flow bus (5–pin M12 male)</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">General</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Power supply</th>
<td>+15–24VDC ±10 % max. ripple recommended: 50mV tt</td>
</tr>
<tr>
<th>Weight</th>
<td>Meter: 1.2 kg Controller: 1.7 kg</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Other</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Note</th>
<td>* optimal accuracy will be reach after approx. 30 minutes after instrument power up</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/b_e_fm_bronkhorst_mini_coriflow.jpeg" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/b_e_fm_bronkhorst_mini_coriflow.jpeg" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Flowmeter mini Cori-Flow</h2>
<p class="list-download__subline">Flowmeter mini Cori-Flow</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Brochure</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">1.2 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="https://www.iconsci.com/wp-content/uploads/2019/09/m14_mini_cori-flow.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/minicoriflowm14flowmeter/">Mini CORI-Flow (M14) flowmeter</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mini CORI-Flow (M13) flowmeter</title>
		<link>https://www.iconsci.com/shop/minicoriflowm13flowmeter/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 27 Aug 2018 15:33:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/minicoriflowm13flowmeter/</guid>

					<description><![CDATA[<p>with mounting block</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/minicoriflowm13flowmeter/">Mini CORI-Flow (M13) flowmeter</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">with mounting block</p>
<p align="justify">Mini CORI-Flow are precise and compact mass flowmeters and controllers, based on the Coriolis measuring principle. Coriolis flowmeters are unmatched in accuracy. When applied for liquids, the mass flow accuracy is better than ±0,2% Rd.</p>
<p align="justify">Instruments of the mini CORI-Flow series contain a uniquely shaped, single loop sensor tube, forming part of an oscillating system. When a fluid flows through the tube, Coriolis forces cause a variable phase shift, which is detected by sensors and fed into the integrally mounted pc-board. The resulting output signal is strictly proportional to the real mass flow rate. The mini CORI-Flow features density and temperature of the fluid as secondary outputs.</p>
<h2 class="headline">Technical Data</h2>
<div class="ginfo">
<h2 class="table-module__header">Flowmeter</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Flow rate range</th>
<td>0.2 &#8211; 50 ml/min</td>
</tr>
<tr>
<th>Flow rate accuracy</th>
<td>± 0.2 % of rate *</td>
</tr>
<tr>
<th>Wetted materials</th>
<td>stainless steel AISI 316 or equivalent optional Hastelloy-C22</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Communication</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Outputs</th>
<td>0 – 5 (10) Vdc or 0 (4) – 20 mA</td>
</tr>
<tr>
<th>Control</th>
<td>standard: RS–232 (8-pinDIN male connection) Profibus-DP® bus:(5-pin M12 female; power 8-pin DIN male) DeviceNet™ Modebus-RTU; LonWorks Flow bus (5–pin M12 male)</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">General</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Power supply</th>
<td>+15–24VDC ±10 % max. ripple recommended: 50mV tt</td>
</tr>
<tr>
<th>Weight</th>
<td>Meter: 1.2 kg Controller: 1.7 kg</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Other</h2>
<table class="table table-bordered table-striped spec-table table-responsive">
<tbody>
<tr>
<th>Note</th>
<td>* optimal accuracy will be reach after approx. 30 minutes after instrument power up</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/b_e_fm_bronkhorst_mini_coriflow.jpeg" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/b_e_fm_bronkhorst_mini_coriflow.jpeg" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">Flowmeter mini Cori-Flow</h2>
<p class="list-download__subline">Flowmeter mini Cori-Flow</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Brochure</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">1.2 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="https://www.iconsci.com/wp-content/uploads/2019/09/m14_mini_cori-flow.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/minicoriflowm13flowmeter/">Mini CORI-Flow (M13) flowmeter</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Upgrade-Kit Flowmeter for AZURA Pilot SMB</title>
		<link>https://www.iconsci.com/shop/upgradekitflowmeterforazurapilotsmb/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Mon, 27 Aug 2018 15:21:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/upgradekitflowmeterforazurapilotsmb/</guid>

					<description><![CDATA[<p>One CORI Flow M14 for AZURA SMB System</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/upgradekitflowmeterforazurapilotsmb/">Upgrade-Kit Flowmeter for AZURA Pilot SMB</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>One CORI Flow M14 for AZURA SMB System</p>
<p align="justify">Use the CORI-Flow M14 to monitor your SMB process and ensure to see every small change in your conditions. The flowmeter are integrated in our SMB software PurityChrom MCC, so you can easily monitor your process and log the flowrate during the whole separation process. Typically two flowmeters are used to monitor the process. Up to four can be included into the system.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/upgradekitflowmeterforazurapilotsmb/">Upgrade-Kit Flowmeter for AZURA Pilot SMB</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>