<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Electrochemical detectors &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/electrochemical-detectors/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Wed, 28 Feb 2018 14:54:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>Electrochemical detectors &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Electrochemical Detector DECADE Elite SCC</title>
		<link>https://www.iconsci.com/shop/electrochemicaldetectordecadeelitescc/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 28 Feb 2018 14:54:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/electrochemicaldetectordecadeelitescc/</guid>

					<description><![CDATA[<p>single cell control, with DC, pulse and scan mode</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/electrochemicaldetectordecadeelitescc/">Electrochemical Detector DECADE Elite SCC</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>single cell control</p>
<p>With its measurement frequency up to 100 Hz, this electrochemical detector is specially designed for super-fast highly sensitive and selective measurement of oxidisable and reducible substances in (U)HPLC. The DECADE Elite comprises of a thermostat-controlled Faraday&#8217;s cage, accommodating column and flow cell. The DECADE Elite unites the three operating modes DC, Pulse and Scan in one instrument. The DC mode covers about 90% of all applications. The pulse mode is important for PAD (Pulsed Amperometric Detection) of e.g. carbohydrates. The scan mode is used to obtain a voltammogram in method optimization. A digital low-pass filter provides an excellent signal-to-noise ratio. For highest sensitivity, the SenCell flow cell is recommended.</p>
<h1 class="headline">Technical Data</h1>
<div class="plusmode">
<h2 class="table-module__header">Puls mode</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Measuring range</th>
<td>10 pA-200 μA in steps of 1, 2 and 5</td>
</tr>
<tr>
<th>Filter (cut off)</th>
<td>Advanced Digital Filter, 0.5 -0.001 Hz in steps of 1, 2 and 5</td>
</tr>
<tr>
<th>Pulse times</th>
<td>t1: 100-2000 ms; t2: 0-2000 ms; t3: 0-2000 ms in steps of 10 ms</td>
</tr>
<tr>
<th>Data recording</th>
<td>20, 40, 60, 80 and 100 ms</td>
</tr>
</tbody>
</table>
</div>
<div class="dcmode">
<h2 class="table-module__header">DC mode</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Measuring range</th>
<td>10 pA-200 μA in steps of 1, 2 and 5</td>
</tr>
<tr>
<th>Filter (cut off)</th>
<td>Advanced Digital Filter, 0.5 -0.001 Hz in steps of 1, 2 and 5</td>
</tr>
<tr>
<th>Noise</th>
<td>&lt; 2 pA with dummy cell</td>
</tr>
</tbody>
</table>
</div>
<div class="scanmode">
<h2 class="table-module__header">Scan mode</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Measuring range</th>
<td>10 pA-200 μA in steps of 1, 2 and 5</td>
</tr>
<tr>
<th>Scan speed</th>
<td>1-50 mV/s in steps of 1, 2 and 5</td>
</tr>
<tr>
<th>Scan cycle</th>
<td>half, complete, continuous</td>
</tr>
</tbody>
</table>
</div>
<div class="ginfo">
<h2 class="table-module__header">Detection</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Detector type</th>
<td>Electrochemical detector</td>
</tr>
<tr>
<th>Version</th>
<td>DC, pulse, scan operating modes</td>
</tr>
<tr>
<th>Detection channels</th>
<td>1</td>
</tr>
<tr>
<th>Working potential</th>
<td>-2.0 V to +2.0 V</td>
</tr>
<tr>
<th>Maximum data rate</th>
<td>10 Hz</td>
</tr>
<tr>
<th>Autozero</th>
<td>triggered via key, TTL, RS-232</td>
</tr>
</tbody>
</table>
</div>
<div class="hzone">
<h2 class="table-module__header">Heated zone</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Thermostatting</th>
<td>oven included</td>
</tr>
<tr>
<th>Temperature range</th>
<td>from 7°C above ambient temperature to 45°C</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Control</th>
<td>RS-232</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Dimensions</th>
<td>220 x 440 x 440 mm</td>
</tr>
<tr>
<th>Weight</th>
<td>14,6 kg without column and flow cell</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/decade_elite_manual_en_2015.png" media="(max-width: 400px)" /><img class="img-responsive text__img" srcset="/wp-content/uploads/2018/02/decade_elite_manual_en_2015.png" alt="" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">DECADE Elite Electrochemical Detector User Manual EN</h2>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">3.1 MB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a class="list-download__btn-top btn btn--teritary btn--icon" href="/wp-content/uploads/2018/02/decade_elite_manual_en_2015.pdf" target="_blank" rel="noopener noreferrer">Download</a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/electrochemicaldetectordecadeelitescc/">Electrochemical Detector DECADE Elite SCC</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>