	<title>ColumnThermostat &#8211; Icon Scientific Inc.</title>
	<atom:link href="https://www.iconsci.com/product-category/columnthermostat/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.iconsci.com</link>
	<description>Highest Quality Liquid Chromatography Products &#38; Service</description>
	<lastBuildDate>Thu, 15 Feb 2018 15:29:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.iconsci.com/wp-content/uploads/2019/03/favicon.png</url>
	<title>ColumnThermostat &#8211; Icon Scientific Inc.</title>
	<link>https://www.iconsci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Upgrade-Kit heating for AZURA SMB</title>
		<link>https://www.iconsci.com/shop/upgradekitheatingforazurasmb/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 15 Feb 2018 15:29:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/upgradekitheatingforazurasmb/</guid>

					<description><![CDATA[<p>SMB oven, heat up to 120°C, suitable for all KNAUER columns (250 x 50 mm)</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/upgradekitheatingforazurasmb/">Upgrade-Kit heating for AZURA SMB</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>SMB oven for up to 8 column with 250 mm length and 50 mm id</p>
<p>This oven can heat up to 120°C. Up to 8 columns (KNAUER) can be placed inside the oven and heated.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Thermostatting</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Temperature range</th>
<td>up to 120°C</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Column compartment</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Column dimensions</th>
<td>up to 120°C</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Interfaces</th>
<td>Display integrated</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>230 V, 50/60 Hz ca. 2000 W,115 V, 50/60 Hz ca. 1700 W</td>
</tr>
<tr>
<th>Dimensions</th>
<td>W x H x D = 585 x 784 x 514 mm (inner dimensions: W x H x D = 400 x 400 x 330 mm)</td>
</tr>
<tr>
<th>Weight</th>
<td>57 kg</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/upgradekitheatingforazurasmb/">Upgrade-Kit heating for AZURA SMB</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Temperature Control for KNAUER Column Heating Sleeve</title>
		<link>https://www.iconsci.com/shop/temperaturecontrolforknauercolumnheatingsleeve/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 15 Feb 2018 15:23:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/temperaturecontrolforknauercolumnheatingsleeve/</guid>

					<description><![CDATA[<p>Temperature Control</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/temperaturecontrolforknauercolumnheatingsleeve/">Temperature Control for KNAUER Column Heating Sleeve</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Control your Column Heating Sleeve</p>
<p>The temperature control can control the temperature of one Heating Sleeve.</p>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>230V,2300W (10A)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/temperaturecontrolforknauercolumnheatingsleeve/">Temperature Control for KNAUER Column Heating Sleeve</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Custom made Column Heating Sleeve for HPLC Columns</title>
		<link>https://www.iconsci.com/shop/custommadecolumnheatingsleeveforhplccolumns/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 15 Feb 2018 15:14:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/custommadecolumnheatingsleeveforhplccolumns/</guid>

					<description><![CDATA[<p>Heat your preparative Columns up, Perfectly fits for your HPLC Columns, Customizable to your needs</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/custommadecolumnheatingsleeveforhplccolumns/">Custom made Column Heating Sleeve for HPLC Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Perfectly fits for your HPLC column</p>
<p>Our column heating sleeves are the perfect solution for thermostatting your preparative column hardware. Regardless if you want to reduce viscosity or improve your performance, the column sleeves are a very compact and cost-effective solution for your preparative column heating tasks. They are available for all preparative KNAUER column dimensions and up to 100°C. Do you need to heat up columns with different dimensions or up to other temperatures? If you are interestet in a customised version, please contact us for more information.</p>
<table>
<caption>Column heating Sleeve</caption>
<tbody>
<tr>
<th scope="col">&nbsp;</th>
<th scope="col">Length</th>
<th scope="col">ID</th>
<th>T<sub>max</sub></th>
</tr>
<tr>
<th rowspan="1" scope="row">A57022</th>
<td rowspan="1">250</td>
<td rowspan="1">4,6</td>
<td rowspan="1">100°C</td>
</tr>
<tr>
<th rowspan="1" scope="row">A57026</th>
<td rowspan="1">150</td>
<td rowspan="1">20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57027</th>
<td>250</td>
<td>20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57028</th>
<td>150</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57029</th>
<td>250</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57030</th>
<td>150</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57031</th>
<td>250</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57032</th>
<td colspan="3" rowspan="1"><b>customizable</b></td>
</tr>
</tbody>
</table>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Thermostatting</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Temperature range</th>
<td>on request</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Column compartment</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Column dimensions</th>
<td>variable dimensions</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>230V</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/custommadecolumnheatingsleeveforhplccolumns/">Custom made Column Heating Sleeve for HPLC Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Column Heating Sleeve for 250 x 50 mm Columns</title>
		<link>https://www.iconsci.com/shop/columnheatingsleevefor250x50mmcolumns/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 15 Feb 2018 14:47:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/columnheatingsleevefor250x50mmcolumns/</guid>

					<description><![CDATA[<p>Heat your preparative Columns up, Perfectly fits for KNAUER Columns, Customizable to your needs</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor250x50mmcolumns/">Column Heating Sleeve for 250 x 50 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Perfectly fits for KNAUER Columns with 250 x 4.6 mm inner dimensions</p>
<p>Our column heating sleeves are the perfect solution for thermostatting your preparative column hardware. Regardless if you want to reduce viscosity or improve your performance, the column sleeves are a very compact and cost-effective solution for your preparative column heating tasks. They are available for all preparative KNAUER column dimensions and up to 100°C. Do you need to heat up columns with different dimensions or up to other temperatures? We can offer you a perfect customizable column sleeve solution A57032.</p>
<table>
<caption>Column heating Sleeve</caption>
<tbody>
<tr>
<th scope="col"> </th>
<th scope="col">Length</th>
<th scope="col">ID</th>
<th>T<sub>max</sub></th>
</tr>
<tr>
<th rowspan="1" scope="row">A57022</th>
<td rowspan="1">250</td>
<td rowspan="1">4,6</td>
<td rowspan="1">100°C</td>
</tr>
<tr>
<th rowspan="1" scope="row">A57026</th>
<td rowspan="1">150</td>
<td rowspan="1">20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57027</th>
<td>250</td>
<td>20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57028</th>
<td>150</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57029</th>
<td>250</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57030</th>
<td>150</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57031</th>
<td>250</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57032</th>
<td colspan="3" rowspan="1">customizable</td>
</tr>
</tbody>
</table>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Thermostatting</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Temperature range</th>
<td>up to 100°C</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Column compartment</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Column dimensions</th>
<td>250 x 4,6 mm</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor250x50mmcolumns/">Column Heating Sleeve for 250 x 50 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Column Heating Sleeve for 250 x 30 mm Columns</title>
		<link>https://www.iconsci.com/shop/columnheatingsleevefor250x30mmcolumns/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 15 Feb 2018 14:18:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/columnheatingsleevefor250x30mmcolumns/</guid>

					<description><![CDATA[<p>Heat your preparative Columns up, Perfectly fits for KNAUER Columns, Customizable to your needs</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor250x30mmcolumns/">Column Heating Sleeve for 250 x 30 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Perfectly fits for KNAUER Columns with 250 x 30 mm inner dimensions</p>
<p>Our column heating sleeves are the perfect solution for thermostatting your preparative column hardware. Regardless if you want to reduce viscosity or improve your performance, the column sleeves are a very compact and cost-effective solution for your preparative column heating tasks. They are available for all preparative KNAUER column dimensions and up to 100°C. Do you need to heat up columns with different dimensions or up to other temperatures? We can offer you a perfect customizable column sleeve solution A57032.</p>
<table>
<caption>Column heating Sleeve</caption>
<tbody>
<tr>
<th scope="col">&nbsp;</th>
<th scope="col">Length</th>
<th scope="col">ID</th>
<th>T<sub>max</sub></th>
</tr>
<tr>
<th rowspan="1" scope="row">A57022</th>
<td rowspan="1">250</td>
<td rowspan="1">4,6</td>
<td rowspan="1">100°C</td>
</tr>
<tr>
<th rowspan="1" scope="row">A57026</th>
<td rowspan="1">150</td>
<td rowspan="1">20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57027</th>
<td>250</td>
<td>20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57028</th>
<td>150</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57029</th>
<td>250</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57030</th>
<td>150</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57031</th>
<td>250</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57032</th>
<td colspan="3" rowspan="1">customizable</td>
</tr>
</tbody>
</table>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Thermostatting</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Temperature range</th>
<td>up to 100°C (other on request)</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Column compartment</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Column dimensions</th>
<td>250 x 30 mm</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>230V, 500W</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor250x30mmcolumns/">Column Heating Sleeve for 250 x 30 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Column Heating Sleeve for 250 x 20 mm Columns</title>
		<link>https://www.iconsci.com/shop/columnheatingsleevefor250x20mmcolumns/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Thu, 15 Feb 2018 14:03:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/columnheatingsleevefor250x20mmcolumns/</guid>

					<description><![CDATA[<p>Heat your preparative Columns up, Perfectly fits for KNAUER Columns, Customizable to your needs</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor250x20mmcolumns/">Column Heating Sleeve for 250 x 20 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Perfectly fits for KNAUER Columns with 250 x 20 mm inner dimensions</p>
<p>Our column heating sleeves are the perfect solution for thermostatting your preparative column hardware. Regardless if you want to reduce viscosity or improve your performance, the column sleeves are a very compact and cost-effective solution for your preparative column heating tasks. They are available for all preparative KNAUER column dimensions and up to 100°C. Do you need to heat up columns with different dimensions or up to other temperatures? We can offer you a perfect customizable column sleeve solution A57032.</p>
<table style="width: 274px;">
<caption>Column heating Sleeve</caption>
<tbody>
<tr>
<th scope="col">&nbsp;</th>
<th scope="col">Length</th>
<th scope="col">ID</th>
<th>T<sub>max</sub></th>
</tr>
<tr>
<th rowspan="1" scope="row">A57022</th>
<td rowspan="1">250</td>
<td rowspan="1">4,6</td>
<td rowspan="1">100°C</td>
</tr>
<tr>
<th rowspan="1" scope="row">A57026</th>
<td rowspan="1">150</td>
<td rowspan="1">20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57027</th>
<td>250</td>
<td>20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57028</th>
<td>150</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57029</th>
<td>250</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57030</th>
<td>150</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57031</th>
<td>250</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57032</th>
<td colspan="3" rowspan="1">customizable</td>
</tr>
</tbody>
</table>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Thermostatting</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Temperature range</th>
<td>up to 100°C (other on request)</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Column compartment</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Column dimensions</th>
<td>250 x 20 mm</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>230V, 400W</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor250x20mmcolumns/">Column Heating Sleeve for 250 x 20 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Column Heating Sleeve for 150 x 50 mm Columns</title>
		<link>https://www.iconsci.com/shop/columnheatingsleevefor150x50mmcolumns/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 14 Feb 2018 18:04:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/columnheatingsleevefor150x50mmcolumns/</guid>

					<description><![CDATA[<p>Heat your preparative Columns up, Perfectly fits for KNAUER Columns, Customizable to your needs</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor150x50mmcolumns/">Column Heating Sleeve for 150 x 50 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Perfectly fits for Knauer Columns with 150 x 50 mm inner dimensions</p>
<p>Our column heating sleeves are the perfect solution for thermostating your preparative column hardware. Regardless if you want to reduce viscosity or improve your performance, the column sleeves are a very compact and cost-effective solution for your preparative column heating tasks. They are available for all preparative KNAUER column dimensions and up to 100°C. Do you need to heat up columns with different dimensions or up to another heating range? We can offer you a perfect customizable column sleeve solution A57032.</p>
<table>
<caption>Column heating Sleeve</caption>
<tbody>
<tr>
<th scope="col">&nbsp;</th>
<th scope="col">Length</th>
<th scope="col">ID</th>
<th>T<sub>max</sub></th>
</tr>
<tr>
<th rowspan="1" scope="row">A57022</th>
<td rowspan="1">250</td>
<td rowspan="1">4,6</td>
<td rowspan="1">100°C</td>
</tr>
<tr>
<th rowspan="1" scope="row">A57026</th>
<td rowspan="1">150</td>
<td rowspan="1">20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57027</th>
<td>250</td>
<td>20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57028</th>
<td>150</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57029</th>
<td>250</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57030</th>
<td>150</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57031</th>
<td>250</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57032</th>
<td colspan="3" rowspan="1">customizable</td>
</tr>
</tbody>
</table>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Thermostatting</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Temperature range</th>
<td>up to 100°C (other on request)</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Column compartment</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Column dimensions</th>
<td>150 x 50 mm</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>230V, 500W</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor150x50mmcolumns/">Column Heating Sleeve for 150 x 50 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Column Heating Sleeve for 150 x 30 mm Columns</title>
		<link>https://www.iconsci.com/shop/columnheatingsleevefor150x30mmcolumns/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 14 Feb 2018 17:20:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/columnheatingsleevefor150x30mmcolumns/</guid>

					<description><![CDATA[<p>Heat your preparative Columns up, Perfectly fits for KNAUER Columns, Customizable to your needs</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor150x30mmcolumns/">Column Heating Sleeve for 150 x 30 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Perfectly fits for KNAUER Columns with 150 x 30 mm inner dimensions</p>
<p>Our column heating sleeves are the perfect solution for thermostatting your preparative column hardware. Regardless if you want to reduce viscosity or improve your performance, the column sleeves are a very compact and cost-effective solution for your preparative column heating tasks. They are available for all preparative KNAUER column dimensions and up to 100°C. Do you need to heat up columns with different dimensions or up to other temperatures? We can offer you a perfect customizable column sleeve solution A57032.</p>
<table>
<caption>Column heating Sleeve</caption>
<tbody>
<tr>
<th scope="col">&nbsp;</th>
<th scope="col">Length</th>
<th scope="col">ID</th>
<th>T<sub>max</sub></th>
</tr>
<tr>
<th rowspan="1" scope="row">A57022</th>
<td rowspan="1">250</td>
<td rowspan="1">4,6</td>
<td rowspan="1">100°C</td>
</tr>
<tr>
<th rowspan="1" scope="row">A57026</th>
<td rowspan="1">150</td>
<td rowspan="1">20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57027</th>
<td>250</td>
<td>20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57028</th>
<td>150</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57029</th>
<td>250</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57030</th>
<td>150</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57031</th>
<td>250</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57032</th>
<td colspan="3" rowspan="1">customizable</td>
</tr>
</tbody>
</table>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Thermostatting</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Temperature range</th>
<td>up to 100°C (other on request)</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Column compartment</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Column dimensions</th>
<td>150 x 30 mm</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>230V, 400W</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor150x30mmcolumns/">Column Heating Sleeve for 150 x 30 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Column Heating Sleeve for 150 x 20 mm Columns</title>
		<link>https://www.iconsci.com/shop/columnheatingsleevefor150x20mmcolumns/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 14 Feb 2018 16:42:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/columnheatingsleevefor150x20mmcolumns/</guid>

					<description><![CDATA[<p>Heat your preparative Columns up, Perfectly fits for KNAUER Columns, Customizable to your needs</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor150x20mmcolumns/">Column Heating Sleeve for 150 x 20 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Perfectly fits for KNAUER Columns with 150 x 20 mm inner dimensions</p>
<p>Our column heating sleeves are the perfect solution for thermostatting your preparative column hardware. Regardless if you want to reduce viscosity or improve your performance, the column sleeves are a very compact and cost-effective solution for your preparative column heating tasks. They are available for all preparative KNAUER column dimensions and up to 100°C. Do you need to heat up columns with different dimensions or up to other temperatures? We can offer you a perfect customizable column sleeve solution A57032.</p>
<table>
<caption>Column heating Sleeve</caption>
<tbody>
<tr>
<th scope="col">&nbsp;</th>
<th scope="col">Length</th>
<th scope="col">ID</th>
<th>T<sub>max</sub></th>
</tr>
<tr>
<th rowspan="1" scope="row">A57022</th>
<td rowspan="1">250</td>
<td rowspan="1">4,6</td>
<td rowspan="1">100°C</td>
</tr>
<tr>
<th rowspan="1" scope="row">A57026</th>
<td rowspan="1">150</td>
<td rowspan="1">20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57027</th>
<td>250</td>
<td>20</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57028</th>
<td>150</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57029</th>
<td>250</td>
<td>30</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57030</th>
<td>150</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57031</th>
<td>250</td>
<td>50</td>
<td>100°C</td>
</tr>
<tr>
<th scope="row">A57032</th>
<td colspan="3" rowspan="1">customizable</td>
</tr>
</tbody>
</table>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Thermostatting</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Temperature range</th>
<td>up to 100°C (other on request)</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Column compartment</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Column dimensions</th>
<td>150 x 20 mm</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>230V, 200W</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/columnheatingsleevefor150x20mmcolumns/">Column Heating Sleeve for 150 x 20 mm Columns</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cartridge for CT 2.1</title>
		<link>https://www.iconsci.com/shop/cartridgeforct21-a05852-2/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 14 Feb 2018 16:26:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/cartridgeforct21-a05852-2/</guid>

					<description><![CDATA[<p>Eluent Pre-heating ID 0.18 mm</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/cartridgeforct21-a05852-2/">Cartridge for CT 2.1</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Cartridge for CT 2.1 Eluent Pre-heating ID 0.18 mm (~ 18 µl)</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/cartridgeforct21-a05852-2/">Cartridge for CT 2.1</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cartridge for CT 2.1</title>
		<link>https://www.iconsci.com/shop/cartridgeforct21-a05852-3/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 14 Feb 2018 16:15:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/cartridgeforct21-a05852-3/</guid>

					<description><![CDATA[<p>Eluent Pre-heating ID 0.1 mm</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/cartridgeforct21-a05852-3/">Cartridge for CT 2.1</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Cartridge for CT 2.1 Eluent Pre-heating ID 0.1 mm (~ 5.5 µl)</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/cartridgeforct21-a05852-3/">Cartridge for CT 2.1</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AZURA Column Thermostat CT 2.1 Keyboad Unit</title>
		<link>https://www.iconsci.com/shop/azuracolumnthermostatct21keyboadunit/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 14 Feb 2018 15:41:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/azuracolumnthermostatct21keyboadunit/</guid>

					<description><![CDATA[<p>optional</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azuracolumnthermostatct21keyboadunit/">AZURA Column Thermostat CT 2.1 Keyboad Unit</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The optional keyboard unit will add a stand-alone functionality to the AZURA Column Thermostat CT 2.1 and Smartline Column Thermostat. This keyboard is mandatory, if no chromatography data system is used.</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azuracolumnthermostatct21keyboadunit/">AZURA Column Thermostat CT 2.1 Keyboad Unit</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AZURA CT 2.1</title>
		<link>https://www.iconsci.com/shop/azuract21/</link>
		
		<dc:creator><![CDATA[Icon Scientific]]></dc:creator>
		<pubDate>Wed, 14 Feb 2018 15:26:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.iconsci.com/products/azuract21/</guid>

					<description><![CDATA[<p>column thermostat for constant temperatures and reproducible results</p>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azuract21/">AZURA CT 2.1</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The AZURA CT 2.1 is a price attractive basic column thermostat. It allows temperature control in the range of 5 °C and 85 °C and thus is appropriate for most HPLC applications. For advanced purification and analysis purposes, the oven can optionally be equipped with an eluent pre-heating cartridge. This ensures even more constant separation conditions leading to higher selectivity and an improved peak shape. The instrument operates with a microprocessor controlled Peltier element for precise temperature settings. In combination with its high temperature stability, this allows programming of linear as well as non-linear temperature gradients.</p>
<h1 class="headline">Technical Data</h1>
<div class="ginfo">
<h2 class="table-module__header">Thermostatting</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Heating and cooling system</th>
<td>microprocessor controlled Peltier element for heating and cooling, fan supported 2-way air circulation</td>
</tr>
<tr>
<th>Temperature range</th>
<td>5–85 °C</td>
</tr>
<tr>
<th>Heating/cooling rate</th>
<td>2 °C/min</td>
</tr>
<tr>
<th>Temperature accuracy</th>
<td>± 0.2 °C</td>
</tr>
<tr>
<th>Temperature stability</th>
<td>± 0.1 °C</td>
</tr>
</tbody>
</table>
</div>
<div class="dinfo">
<h2 class="table-module__header">Column compartment</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Column dimensions</th>
<td>
<table border="0" style="width: 601px;" cellpadding="0">
<thead>
<tr>
<td>
<p>max. number</p>
</td>
<td>
<p>max. length*</p>
</td>
<td>
<p>max. outer diameter*</p>
</td>
<td valign="top">
<p>matching Vertex Plus column</p>
</td>
</tr>
</thead>
<tbody>
<tr>
<td>
<p>8</p>
</td>
<td>
<p>160 mm</p>
</td>
<td>
<p>12 mm</p>
</td>
<td valign="top">
<p>125 mm x 4.6 mm ID with precolumn</p>
</td>
</tr>
<tr>
<td>
<p>4</p>
</td>
<td>
<p>325 mm</p>
</td>
<td>
<p>12 mm</p>
</td>
<td valign="top">
<p>300 mm x 4.6 mm ID</p>
</td>
</tr>
<tr>
<td>
<p>1</p>
</td>
<td>
<p>325 mm</p>
</td>
<td>
<p>35 mm</p>
</td>
<td valign="top">
<p>300 mm x 16 mm ID</p>
</td>
</tr>
</tbody>
</table>
<p>*total outer dimensions of the column including screw caps</td>
</tr>
<tr>
<th>Dimensions, interior</th>
<td>90 x 390 x 47 mm (W x H x D)</td>
</tr>
<tr>
<th>Safety</th>
<td>self-check and auto-calibration at power-on, <br />selectable turn-off temperature</td>
</tr>
<tr>
<th>Leak sensor</th>
<td>adjustable sensitivity, acoustic signal, turn-off switch</td>
</tr>
</tbody>
</table>
</div>
<div class="communication">
<h2 class="table-module__header">Communication</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Control</th>
<td>optional for Stand-alone functionality:</p>
<ul>
<li>keyboard unit with LCD</li>
<li>Mobile Control</li>
</ul>
</td>
</tr>
<tr>
<th>Interfaces</th>
<td>LAN Interface</td>
</tr>
</tbody>
</table>
</div>
<div class="general">
<h2 class="table-module__header">General</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Power supply</th>
<td>90–230 V, 50–60 Hz, 100 W</td>
</tr>
<tr>
<th>Dimensions</th>
<td>150 x 470 x 310 mm (W x H x D)</td>
</tr>
<tr>
<th>Weight</th>
<td>8.4 kg</td>
</tr>
</tbody>
</table>
</div>
<div class="other">
<h2 class="table-module__header">Other</h2>
<table class="table-module__table">
<tbody>
<tr>
<th>Optional accessories</th>
<td>Cartridge for Eluent pre-heating for capillary with an ID of 0.1 or 0.18 mm</td>
</tr>
</tbody>
</table>
</div>
<div id="download" class="downloadpd">
<h2 class="table-module__header">Downloads and more information</h2>
<ul class="list-download">
<li class="list-download__item list__item item  loaded">
<div class="container">
<div class="flex">
<div class="list__img"><picture><source srcset="/wp-content/uploads/2018/02/v6810_azura_ct_2.1_user-manual_en.png" media="(max-width: 400px)" /><img srcset="/wp-content/uploads/2018/02/v6810_azura_ct_2.1_user-manual_en.png" alt="" class="img-responsive text__img" /> </picture></div>
<div class="list-download__text">
<h2 class="list-download__headline">AZURA Column Thermostat CT 2.1 User Manual EN (V6810)</h2>
<p class="list-download__subline">&nbsp;</p>
<div class="row flex">
<div class="col-2-3">
<ul class="list-download__tags">
<li class="list-download__tags-item">Manual</li>
<li class="list-download__tags-item">English</li>
<li class="list-download__tags-item">PDF</li>
<li class="list-download__tags-item">499.8 KB</li>
</ul>
</div>
<div class="col-1-3">
<div class="list-download__cta"><a href="/wp-content/uploads/2018/02/v6810_azura_ct_2.1_user-manual_en.pdf" target="_blank" class="list-download__btn-top btn btn--teritary btn--icon" rel="noopener noreferrer">Download<span class="icon-arrow-right"></span></a></div>
</div>
</div>
</div>
</div>
</div>
</li>
</ul>
</div>
<p>The post <a rel="nofollow" href="https://www.iconsci.com/shop/azuract21/">AZURA CT 2.1</a> appeared first on <a rel="nofollow" href="https://www.iconsci.com">Icon Scientific Inc.</a>.</p>
]]></content:encoded>
					
		
		